AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
AIDA
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Mar 29 12:36:51 2025
Author
*
:
Subject
*
:
MSL type BB18 serial # 2977-20 bias +100V I_L +12.45uA T=23 deg C (biased by nnaida # 3 & 5 ) DSSSD - AIDA adaptor PCB cabling 4 off LH Coupler (Kapton PCB, 5cm), 2x 34-way Samtec ribbon cable (62cm p+n, 53cm n+n), RH coupler(Kapton PCB, 10cm) + 3M 1245 1.4mil copper foil screen ribbon cables (i.e. not RH & LH couplers) + drain wires -> gold-plated Lemo-00 test input connectors to FEE64s in 4x FEE module crates 3M 1245-wrapped cables enclosed by polyethyelene bags (supplied to deliver 90cm Printech Kapton PCBs) to ensure no electrical contact with snout, DSSSD mounting tubes, snout base etc Snout drain wire to FEE module Cu block nnaida 3 & 8 AIDA adaptor PCB rev C nnaida 5 & 9 AIDA adaptor PCB rev C (LK1 fitted) ground links LK3 & LK7 *not* fitted to nnaida3, 5, 8, & 9 AIDA adaptor PCBs LK1 fitted to nnaida5 ( cf. https://elog.ph.ed.ac.uk/AIDA/190 ) Heavy duty copper cable connects copper front end frames of FEE modules Nitto 5011N conductive gasket between FEE module and front end frames Standard ASIC settings nnaida 3 & 8 - negative input nnaida 5 & 9 - positive input Pulser BNC PB-4 Fall time 1.0ms Rate c.100Hz Delay min Amplitude 50,000 Polarity - Pulse top Tail Atten 10x + polarity via EG&G Ortec 433A Sum & Invert Amplifier Standard ASIC settings Shaping time 8us LEC/MEC Slow com 32 (dec) Fast com 32 (dec) HEC Fast com 2(dec) Attachments 1-4 ASIC #1 waveforms from each FEE64 5-8 ASIC #2 spectra + 2.0.L pulser peak width Pulser peak widths (ch FWHM) versus shaping time ( spectrum 2.4.L ) tau nnaida3 nnaida5 nnaida8 nnaida9 8 68 60 70 62 4 83 49 88 48 2 100 47 109 43 1 172 60 165 42 0.5 380 86 309 48 Note: n+n ohmic strips spectra > 100 ch FWHM display non-gaussian peaks/double peaking 15.45 Attempted to increase detector bias from +100V to +150V Leakage current increased ~0.5uA/V for bias > 115V Detector bias supply trips (20uA) at +120V Remain at detector bias +100V 16.17 Switch polarity of detector bias from + to - Move LK1 from nnaida5 to nnaida3 tau nnaida3 nnaida5 nnaida8 nnaida9 8 61 64 65 61 n+n ohmic strips ~10% improvement, p+n junction strips no significant change 16.30 Fit LK3/LK7 jumpers to connect adaptor PCB ground to detector PCB ground tau nnaida3 nnaida5 nnaida8 nnaida9 8 61 64 62 60 No significant change to cf. previous test 18.30 Install second DSSSD Upstream 3058-6 bias +100V I_L 4.15uA Downstream 2977-20 bias +100V I_L 11.8uA + 207Bi source ~3cm upstream of 3058-6 Standard ASIC settings shaping time 6us slow comp 8(dec) HEC fast comp 2(dec) LEC/MEC fast comp 16(dec) Pulser peak widths ~60 ch FWHM per previous tests today Discriminator masks TBD 22.27 R2 to disk (directory /data20/TapeData/May2016) MERGE data links 2-9 Run data to disk overnight. Add two more DSSSDs tomorrow. 09.21 R2 stopped
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown