AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
AIDA
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Tue Apr 22 06:15:17 2025
Author
*
:
Subject
*
:
The program for online monitoring the correlation of the DAQ systems (AIDA-EURICA-BigRIPS) through a common scaler is SyncCheck (J. Agramunt). The code runs in the d05 server, receiving data transferred to a DataSink from each of the individual DAQs. The data transfer is done with the DataRelayFilter code for AIDA (AE), and the euricatssender and ribftssender (Baba-san) codes for EURICA and RIBFdaq, respectively. The attached screenshots show how to setup these programs. Follow these steps: 1) Log in to d05 as user 'aida'. Start an instance of the DataSink code with option -i 3 (3 data stream, which will use ports 10305 to 10307). The code is saved in /home/aida/DataPackage/DataSink/Linux64 2) In the d05 server start the following codes: euricatssender (in /home/aida/ribfts/euricatssender/ directory), and ribftssender (in /home/aida/ribfts/ribftssender/ directory). If you give the codes dummy command line option (e.g. -X) the value of transferred timestamps will be printed to screen as diagnostics. 3) In the AIDA computer (aidas1), start the DataRelayFilter program (will work from any directory). As command line arguments provide the IP address of d05, and the TCP port and id of the data stream for the DataSink program: DataRelayFilter -n 10.32.0.12 - p 10307 -I 2 Only the master FEE will produce correlation scalar items (?). The code has as default NNAIDA5 for the module where to search for the Corr Scaler items; if this has to be changed use command line option -m X (where X is NNAIDAX number for new master FEE) 4) Back in the d05 server start the SyncCheck program, in the directory /home/aida/SyncCheck/. You can give as an argument the ID of the Master data stream for the synchronization check, through "-M ID" (should be done if one of the three data streams is down). For example "SynCheck -M 2" will use AIDA as the master timestamp. 5) Perform a manual correlation reset request to synchronize the value of the correlation scaler in all three DAQs. This is done with the button 'Force Correlation Reset' of the AIDA "Correlation Status & Control" webpage (attachment 2), which can be accessed from the MIDAS web- based control of AIDA. The SyncCheck code will display a few spectra for onine monitoring of DAQ correlation (attachment 3, shown only with AIDA and EURICA running). A peak will appear showing the offset in the correlation scaler between the different DAQs. The counts in the peak should increase continuously, and its position should not change. If it doesn't, try sending a Correlation Reset signal (step 5). If this does not fix the monitor, report a correlation error! Further information on the scheme for data synchronization is here: https://elog.ph.ed.ac.uk/BRIKEN/6 https://elog.ph.ed.ac.uk/BRIKEN/5
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown