Mon May 23 07:28:38 2016
Author
*
:
Subject
*
:
12.45 Rly16 'Sequence ALL On' operational 15.20 Startup remote control of CAEN N1419 4-ch HV modules DSSSD #1-7 leakage currents OK - see attachments 1-2 Ambient temperature +24.8 deg C 15.35 Plot Temperature appears to plot the first 15,000 (or so) temperature readings and not the *most recent* 15,000 (or so) readings. See attachment 3. There is no way to change the time window for the temperature plot As a workaround, empty file using the command cp /dev/null /MIDAS/log/temperatures.txt 17.10 For all FEEs (*except nnaida19 & nnaida26) which are currently disconnected) reprogram FEE flash memory using FEE_GF_Feb16_17.bin Power cycle attempt #1 - wait 4' STATE for nnaida9 returned with an error connect failed NONE connect failed attempt #2 - wait 6' STATE for nnaida4 returned with an error connect failed NONE connect failed attempt #3 - wait 8' - OK Installed updated Check software - Check.tml .tcl .js and Common.js Started DAQ - histogramming enabled - data transfer disabled Large fraction of FEEs not producing SYNCs, SYNC rate low (~20-30Hz) for other FEEs - see attachments 4 & 5 Note slow comparator 0xc8 (i.e. high) and fast discriminators (LEC/MEC) disabled Firmware version - attachment 6 System wide checks ASIC clock sync (30/30 fail) and ADC calibration (7/30 fail) work as before but new checks produce errors - see attachments 7-11 Additional screenshots from Master Timestamp Control - see attachments 12-17 00:40 PJCS identifies workaround to above problems - correlation controls now enabled for master timestamp FEE (nnaida5) only. May also explain issues with nnaida19 & nnaida26. PJCS will produce detailed, separate Elog entries Currently, all (30) FEE64s running OK with sensible AIDA SYNC rates. But. No spare fuses (16A/250V slow blow) for USB-controlled ac mains relay. Until Chris arrives in c. 9h. We will explore options to use *second* USB-controlled ac mains relay.
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Resubmit as new entry
Attachment 1:
2.png
Original size: 502x344
Attachment 2:
3.png
Original size: 502x344
Attachment 3:
4.png
Original size: 1596x970
Attachment 4:
20.png
Original size: 1596x1029
Attachment 5:
21.png
Original size: 1596x1029
Attachment 6:
22.png
Original size: 1596x1029
Attachment 7:
30.png
Original size: 1596x1029
Attachment 8:
31.png
Original size: 1596x1029
Attachment 9:
32.png
Original size: 1920x1080
Attachment 10:
33.png
Original size: 1596x1029
Attachment 11:
34.png
Original size: 1596x1029
Attachment 12:
40.png
Original size: 1596x1029
Attachment 13:
41.png
Original size: 1596x1029
Attachment 14:
42.png
Original size: 1596x1029
Attachment 15:
44.png
Original size: 1596x1029
Attachment 16:
43.png
Original size: 1596x1029
Attachment 17:
45.png
Original size: 1596x1029
Attachment 18:
50.png
Original size: 1596x1029
Attachment 19:
51.png
Original size: 1596x1029
Attachment 20:
52.png
Original size: 1596x1029
Attachment 21:
60.png
Original size: 1596x1029
Attachment 22:
61.png
Original size: 1596x1029
Attachment 23:
62.png
Original size: 1596x1029
Attachment 24:
63.png
Original size: 1596x1029
Attachment 25:
65.png
Original size: 1596x1029
Attachment 26:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown