1) Start Julabo FL11006 Recirculating Chiller See manual (page 19) http://www2.ph.ed.ac.uk/~td/AIDA/Information/Julabo%20FL11006.pdf Set point +20 deg C Check flow of coolant by inspecting the two flow indicators the left and right hand sides on top of the AIDA stand Do NOT proceed if the Julabo FL11006 Recirculating Chiller is not operating, or if there is little, or no, flow in one, or both, flow indicators. 2) Start interface to USB-controlled ac mains relay to AIDA data acquisition servers On the AIDA Dell T410 Workstation aidas1 switch to Desktop 7 and atart a Firefox web browser Enter URL http://nnrpi1:8015/AIDA/Rly16/ See attachment 1 Select 'Sequence ALL On' to powerup the AIDA data acquisition servers Check all relays Relay 1 to Relay 8 move from the 'Switch ON' to 'Switch OFF' row See attachment 2 Wait 8 minutes (yes - really!) before proceeding 3) Start Httpd Data Acquisition server See attachment 3 Switch to Desktop 1 and select MIDAS yellow icon 'Httpd for DataAcquisition' which will start a terminal to display server messages as follows System identified is CPU x86_64; Platform is unix; OS is Linux and Version is 2.6.32-504.8.1.el6.x86_64 Environment selected is CPU x64_64; Platform unix; OS Linux64 and Operating System Linux64 MIDASBASE = /MIDAS@aidas and MIDAS_LIBRARY = /MIDAS@aidas/TclHttpd/Linux64 PATH = /MIDAS@aidas/bin_Linux64:/MIDAS@aidas/TclHttpd/Linux64:/homes/npg/root/bin:/homes/npg/root/bin:/homes/npg/root/lib:/MIDAS/Linux/bin64:/usr/lib64/qt-3.3/bin:/usr/local/bin:/usr/bin:/bin package limit is not available: can't find package limit Running with default file descriptor limit package setuid is not available: can't find package setuid Could not change to user 50 group 50: not owner /debug user "debug" password "jhi+u8jzdbpl" httpd started on port 8015 Custom startup from /MIDAS@aidas/config/TclHttpd/aidas1@8015/startup.tcl DefineMessage defined with server at http://elog.ph.ed.ac.uk:8015/MessageLoggerServer /DataBaseAccessServer /NetVarService /SigTaskService Loaded MemSasAccess /SpectrumService loading tcl/AIDARunControl.tcl for namespace :: RunControlClient provided RunControlClient loaded Completed custom startup from /MIDAS@aidas/TclHttpd/Html/AIDA/RunControl/stats.defn.tcl See attachment 4 4) Start web browser for interface to AIDA Switch to Desktop 1 and start Firefox web browser Enter URL localhost:8015 See attachments 5-6 5) Commence startup of AIDA interface Select AIDA Experiment Control 6) From AIDA Experiment Control tab See attachment 7 Select AIDA Hardware Control See attachment 8 Re-select AIDA Experiment Control tab Select Data Acquisition Run Control 7) From Data Acquisition Run Control tab See attachment 9 Select Act On ALL Data Acquisition Servers See attachment 10 Select Reset Wait for update and check state of *all* data acquisition servers is 'reset' Select Setup See attachment 11 Wait for timestamp re-synchronisation pop-up See attachment 12 Usually all data acquisition servers (nnaida1, nnaida2 ... etc) will ReSYNC OK Sometimes one, or more, data acquisition servers report ReSYNC not complete Re-select AIDA Hardware Control tab and select Master Timestamp Control From the Master Timestamp Control tab Select Reload Select FEE64 -> nnaida6 Select Perform ReSYNC See attachment 13 Wait for timestamp re-synchronisation pop-up See attachments 14-15 8) AIDA: Master Timestamp Control Ditto ReSync 7) Data Acquisition Run Control 8) Spectrum Browser
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown