AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
AIDA
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Mar 29 19:43:41 2025
Author
*
:
Subject
*
:
> All AIDA operations are controlled from the Dell T410 Workstation aidas1 using web browsers. > > AIDA has multiple, independent data acquisition servers connected by an Ethernet network. > > Response times to commands, information updates etc are ~10-60s - please be patient! > > > > How To Start Run > > 1) Workspace 1 - Firefox web browser - Run Control tab > > Select Update > > Check DAQ stopped (green GO button displayed) > > Check state of *all* data acquisition servers is 'stopped' and histogramming and data transfer > is enabled indicated by 'H X' > > See attachment 1 > > 2) Workspace 2 - Firefox web browser - TapeServer tab > > Check Reload > > Check TapeServer stopped and disk file closed (green GO button displayed) > > See attachment 2 > > 3) Workspace 2 - Firefox web browser - MERGE tab > > Check Reload > > Check Merge Program paused - see banner > > Merge State = GOing : paused : xfer enabled : output paused > > If not paused select Toggle Merge Program Pause State > > See attachment 3 > > 4) Workspace 1 - Firefox web browser - ASIC Control tab > > Check Reload > > Check 'Act on ALL FEE64 modules?' and wait for request to be completed > > Check 'Act on ALL ASICs' and wait for request to be completed > > From 'Select required function' select 'Check ASIC Control' > After ~60s a pop-up will appear showing the response from each ASIC of each data acquisition server. > Check all ASICs are OK and status = 0x001F0000. > Dismiss pop-up by selecting OK > > See attachments 4-5 > > 5) Workspace 1 - Firefox web browser - Run Control tab > > Start DAQ - select green GO button > > Wait (~60s) until state of all data acquisition servers (nnaida1, nnaida2 ... etc) updates > > Select 'Data Acquisition Statistics' > > 6) Workspace 1 - Firefox web browser - Statistics tab > > Check Reload > > Check 'Show ALL Data Acquisition Servers' > > From 'Select counter to Monitor' select 'AIDA SYNC' > > Select 'Update Once' > > Check *all* data acquisition servers have a non-zero rate (typically ~300-500Hz) > > See attachment 6 > > N.B. If one, or more, data acquisition servers have zero rate > > return to Run Control tab > > stop DAQ (select red STOP button) > > check state of *all* data acquisition servers is 'stopped' with histogramming and > data transfer are enabled indicated by 'H X' > > start DAQ (select green GO button) > > check state of *all* data acquisition servers is 'going' with histogramming and > data transfer are enabled indicated by 'H X' > > return to Statistics tab > > check AIDA SYNC rates again and if zero rate persists for one, or more, data acquisition > servers call for expert help and do *NOT* proceed! > > 7) Workspace 2 - Firefox web browser - TapeServer tab > > Start TapeServer and open disk file - select green GO button > > 8) Workspace 2 - Firefox web browser - MERGE tab > > Select 'Reload' several times and check all enabled data links (0-23) are active > bright green = active, olive green = inactive, red = disabled > > N.B. If some data links are *always* inactive call for expert help and do NOT proceed! > > Select Toggle Merge Program Pause State to enable data merging > > Select Reload to observe merge rate (data items/s) > > Observe active spinners in MERGE and TapeServer server terminal windows adjacent to web browser > > See attachment 7 > > 9) Workspace 2 - Firefox web browser - TapeServer tab > > Select Reload and observe number of blocks written to disk > > 10) Workspace 1 - Firefox web browser - Control tab > > Select 'Save/Restore Settings' > > From 'Save/Restore Module Settings' tab > > select 'Reload' > > select 'Module Names' whose settings should be saved (usually all) > > select 'Generate new DB key' and make a note of the DB key generated > the DB key will have the format YYYYMMMDD-HH.MM.SS > > The DB key will be used to name a directory to store AIDA settings > and is created uid: npg, gid: npgstaff, perms 755. However, its > contents are written uid: nfsnobody, gid nfsnobody. The default > directory (DB Key) permissions do not work - change the permissions > to 777 - before attempting to save data to this directory (DB Key). > > launch a terminal and change the permissions of the DB key directory using the command > > chmod 777 /MIDAS/DB/EXPERIMENTS/AIDA/[YYYYMMMDD-HH.MM.SS] > > select 'Save Settings' to save AIDA ASIC, LED and waveform settings to > the directory (DB key) > > 11) Update EURICA 2016 Elog with the following information > > AIDA > run filename (e.g. R99) > [# data blocks] > start date & time > [stop date & time] > ASIC settings DB key > AIDA trigger (e.g. OR DSSSDs #1 - #6) > additional comments > your name > > Complete run sheet for written logbook > > > > How to Stop Run > > 1) Workspace 2 - Firefox web browser - MERGE tab > > Pause MERGE input - select Toggle Merge Program Pause State > > 2) Workspace 1 - Firefox web browser - Run Control tab > > Select Update > > Stop DAQ - select red STOP button > > Wait (~60s) until state of all data acquisition servers (nnaida1, nnaida2 ... etc) updates > > Check state of *all* data acquisition servers is 'stopped' > > 3) Workspace 2 - Firefox web browser - TapeServer tab > > Stop TapeServer and close disk file - select red STOP button > > 4) Complete EURICA 2016 Elog with the following information > > AIDA > run filename (e.g. R99) > [# data blocks] > start date & time > [stop date & time] > ASIC settings DB key > AIDA trigger (e.g. OR DSSSDs #1 - #6) > additional comments > your name > > Complete run sheet for written logbook > > > > >
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown