Subject
*
:
> Every 4h > > 1) Record DSSSD #1 = #6 detector bias voltages and leakage currents in written logbook > > Desktop 6 - 2x PUTTY terminal sessions > > Each PUTTY terminal session is connected to a CAEN N1419 4 ch HV Power Supply > > Addr 00 > > Ch 0 = DSSSD # 1 > : > : > Ch 3 = DSSSD # 4 > > Addr 01 > > Ch 0 = DSSSD # 5 > Ch 1 = DSSSD # 6 > > Compare with previous observations > > 2) Desktop 1 - Firefox web browser - Temperatures tab > > Select Reload > > Check temperatures > > Virtex < 75 deg C > PSU < 45 deg C > ASIC < 65 deg C > > If not call for expert help. > > Note that the ASIC temperatures for some data acquisition servers sometimes read back as 0.0 > > > *If* DAQ running also > > > 3) Desktop 1 - Firefox web browser - Statistics tab > > Check Reload > > Check 'Show ALL Data Acquisition Servers' > > From 'Select counter to Monitor' select 'AIDA Discriminator' > > Select 'Update Once' > > Check *all* data acquisition servers have a non-zero rate > > N.B. If one, or more, data acquisition servers have zero rate call for expert help! > > From keyboard select Alt-Print Screen and save screenshot to /tmp directory as a .png file > Upload the .png file to the EURICA 2016 Elog for the current run > > Compare rates with previous observations at same settings > > 4) Desktop 1 - Firefox web browser - Statistics tab > > Check Reload > > Check 'Show ALL Data Acquisition Servers' > > From 'Select counter to Monitor' select 'AIDA SYNC' > > Select 'Update Once' > > Check *all* data acquisition servers have a non-zero rate (typically ~300-500Hz) > > N.B. If one, or more, data acquisition servers have zero rate call for expert help! > > 5) Desktop 2 - Firefox web browser - MERGE tab > > Select 'Reload' several times and check all enabled data links (0-23) are active > bright green = active, olive green = inactive, red = disabled > > N.B. If some data links are *always* inactive call for expert help! > > Select Reload to observe merge rate (date items/s) > > Observe active spinners in MERGE and TapeServer server terminal windows adjacent to web browser > > 6) Desktop 2 - Firefox web browser - TapeServer tab > > Select Reload and observe number of blocks written to disk
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown