Friday 3 June 2016 |
|
|
11.00 Detector biases and leakage currents - see attachments 1-2
FEE64 temperatures - see attachment 3
DAQ ran overnight without problem - statistics - attachments 4-8
Plan for today
1) Develop AIDA external trigger output for fast LEC/MEC discriminator threshold 0x4, or lower
2) Replace non-rev B MACB with rev B MACB in master timestamp chain (NIM module #2)
16.15 Non-rev B MACB in master timestamp chain replaced with rev B MACB module
FEE64s power cycled and rebooted.
System ReSYNC'd successfully
System-wide tests
clock states 24/24 pass
adc calibration 24/24 pass
ASIC clock timestamp check 23/24 pass, nnaida19 fails
SYNC errors not counting 23/24 pass, nnaida19 fails
N.B. We obtained the same nnaida19 errors before rpelacing non-rev B MACB *and* with FEE64
previously installed as nnaida19
Module timestamps - see attachment 9
Master timestamp module nnaida6 - all clocks locked
Fitted ground jumpers to front and rear field plate connections on all four adaptor PCBs
for each of DSSSD#2 - #5, i.e. DSSSD#1 - #6 now have field plate ground jumpers fitted.
See attachments 10 & 11 showing discriminator rates before and after fitting these additional
ground jumpers (LEC/MEC fast discriminator threshold 0x4 or 0x5)
18.25 NP1306 R58
207Bi + 60Co LEC/MEC disc threshold test
ASIC settings 2016Jun03-21.03.42
21.05 End R58
21.30 Moved extant data acquisition server options files to /MIDAS/DB/EXPERIMENT/AIDA/nnaida?/CONTENTS.BAK-030616
Saved options for all data acquisition servers with
TS_SYNC_PHASE = 0x3
MACB_TRIG_MODE = 0x4
ASIC Settings DB key 2016Jun03-21.03.42
(all LEC/MEC fast disc settings 0x5 *except* nnaida5 & nnaida6 = 0x20)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|