Entry time:
Sat Mar 29 12:37:26 2025
Author
*
:
Subject
*
:
04.45 Lowered slow comp threshold on all FEEs bar nnaida24 to 8 (nnaida24 @ 12). Fast comp thresh @ 6 on all nnaida. See CPU load and MIDASsort in attachments 1+2. 11.20 Directory /MIDAS/SpecData moved to /ntfs/TapeData/NP1306/ (Edinburgh Seagate USB 8Tb disk Z840DXMA) to create disk space on root filesystem (100% usage, 134M remaining space) 11.36 Saved current *.L spectra to /MIDAS/SpecData 11.40 Detector biases & leakage currents - OK - see attachments 3-4 FEE64 temperatures - see attachment 5 12.15 Julabo FL11006 set point +15 deg C (B2F/F11 temp +25.5 deg C, d.p. +12.9 deg C , RH 45.4% ) changed set point from +15 to +17 deg C 13.18 FEE64 temperatures - see attachment 6