Sun Mar 30 09:18:10 2025
Author
*
:
Subject
*
:
11.00 Restore power to AIDA following Saturday's shutdoen in preparation for the planned maintenance outage on Sunday. Restart Julabo FL11006 chiller - set point +20 deg C Restart AIDA Temperature +24.3 deg C, DP +15.2 deg C, RH 57.5% DSSSD #1-6 bias - see attachments 1-2 FEE64 temperatures - attachment 3 System-wide checks - see attachments 4-8 Note SYNC pulses received by *all* slave FEE64s = SYNC pulses sent by master FEE64 (nnaida6) 11.35 R6 starts slow comparator 0x10 LEC/MEC fast comparator 0x10 All FEE64 discriminator masks -> 0x0 observe very high rates (~400-500kHz/FEE64) from majority ofp+n junction FEE64s LEC/MEC fast comparator -> 0xff 18.45 DAQ running OK No merger error messages since change of LEC/MEC fast comparator threshold -> 0xff Offline analysis of R6_79 confirms that all FEE64s are synchronised Added correlation trigger input BNC PB-4 Pulser trigger output -> Ortec SCA + NIM output width 0.5us -> LeCroy 429A -> root MACB trigger #4 input 21.05 R7 starts Attachments 9-16 show FEE64 temperatures and results of each system-wide check. Note the result of the Master Timestamp Control -> Check Clock Lock States indicating clock state *not* locked slow comparator 0x10 LEC/MEC fast comparator 0xff All FEE64 discriminator masks -> 0x0