Entry time:
Fri Sep 30 03:35:12 2016
Author
*
:
Subject
*
:
11.37 Attempt to use external 50MHz clock for Master MACB (w/ 50MHz front panel label) NIM 50MHz -> NIM-TTL translator -> Master MACB (rear panel) Master MACB mode 0 -> 5 Fails to ReSync, clock errors etc - see attachments 1-5 Change NIM 50MHz -> 25MHz (to improve signal quality) and attempt ReSync (no power FEE64 power cycle) - no change 14.30 Master MACB mode -> 0 NIM 25MHz -> Master MACB correlation clock input (front panel) BNC PB_4 frequency c. 26Hz Trigger output -> SCA -> LeCroy 429A -> Master MACB accepted trigger input ./analyser2 v /TapeData/Sept2016/R5_0 | grep MBS : : *** MBS information: block: 471 ptr: 7203 data: 0x86807CAB module: 6 information type: 8 information index: 0 MBS data:7CAB ts: 0x00000017AC2C4582 *** MBS information: block: 471 ptr: 7205 data: 0x8681575E module: 6 information type: 8 information index: 1 MBS data:575E ts: 0x00000017AC2C4582 *** MBS information: block: 471 ptr: 7207 data: 0x86820000 module: 6 information type: 8 information index: 2 MBS data:0000 ts: 0x00000017AC2C4582 *** MBS information: block: 471 ptr: 15767 data: 0x86800FA8 module: 6 information type: 8 information index: 0 MBS data:0FA8 ts: 0x00000017AC669176 *** MBS information: block: 471 ptr: 15769 data: 0x8681576D module: 6 information type: 8 information index: 1 MBS data:576D ts: 0x00000017AC669176 *** MBS information: block: 471 ptr: 15771 data: 0x86820000 module: 6 information type: 8 information index: 2 MBS data:0000 ts: 0x00000017AC669176 0x576D0FA8 - 0x575E7CAB = 0xE92FD = 955133 * 40ns = 38205320ns = 38.2ms => 26Hz 0x00000017AC669176 - 0x00000017AC2C4582 = 0x3a4bf4 = 3820532 * 10ns = 38205320ns QED 15.45 Master MACB mode 0 -> 5 NIM 50MHz -> Phillips 726 NIM-TTL-NIM -> Master MACB external clock (rear panel) Phillips 726 provides better quality TTL signal with c. 3ns rise/falltimes and 3.5V amplitude into 50 Ohm cf. NIM-TTL-NIM module used previously See http://www.phillipsscientific.com/pdf/726ds.pdf RESET/SETUP DAQ OK System-wide checks OK *except* nnaida19 fails ASIC timestamp check (no change) Start test run R6_0 to disk but no AIDA issue correlation triggers are recorded Can manually issue correlation triggers and resets via Correlation Status & Control tab Observe statistics count 3x for each trigger and reset - see https://elog.ph.ed.ac.uk/AIDA/362 aidas1> ./analyser2 v /TapeData/Sept2016/R6_0 | grep MBS : : Test #1 - manual correlation trigger *** MBS information: block: 9626 ptr: 9991 data: 0x86807774 module: 6 information type: 8 information index: 0 MBS data:7774 ts: 0x00000077517D2816 *** MBS information: block: 9626 ptr: 9993 data: 0x86817213 module: 6 information type: 8 information index: 1 MBS data:7213 ts: 0x00000077517D2816 *** MBS information: block: 9626 ptr: 9995 data: 0x86820003 module: 6 information type: 8 information index: 2 MBS data:0003 ts: 0x00000077517D2816 : : Test #2 - manual correlation trigger x2 separated by ~10s *** MBS information: block: 16751 ptr: 10787 data: 0x86807285 module: 6 information type: 8 information index: 0 MBS data:7285 ts: 0x000000833335145A *** MBS information: block: 16751 ptr: 10789 data: 0x86816A81 module: 6 information type: 8 information index: 1 MBS data:6A81 ts: 0x000000833335145A *** MBS information: block: 16751 ptr: 10791 data: 0x86820006 module: 6 information type: 8 information index: 2 MBS data:0006 ts: 0x000000833335145A *** MBS information: block: 16929 ptr: 8209 data: 0x86807BC5 module: 6 information type: 8 information index: 0 MBS data:7BC5 ts: 0x000000837F39395A *** MBS information: block: 16929 ptr: 8211 data: 0x86817D82 module: 6 information type: 8 information index: 1 MBS data:7D82 ts: 0x000000837F39395A *** MBS information: block: 16929 ptr: 8213 data: 0x86820006 module: 6 information type: 8 information index: 2 MBS data:0006 ts: 0x000000837F39395A 0x67D827BC5 − 0x66A817285 = 0x13010940 = 318835008 × 20ns = 6376700160ns = 6.4s 0x837F39395A - 0x833335145A = 0x4C042500 = 1275340032 * 10ns = 12753400320ns = 12.8s => correlation clock frequency = 25MHz *not* 50MHz : : Test #3 - manual correlation reset, followed by correlation trigger ~2s later *** MBS information: block: 17065 ptr: 15987 data: 0x86804D22 module: 6 information type: 8 information index: 0 MBS data:4D22 ts: 0x00000083B96F05A6 *** MBS information: block: 17065 ptr: 15989 data: 0x86810344 module: 6 information type: 8 information index: 1 MBS data:0344 ts: 0x00000083B96F05A6 *** MBS information: block: 17065 ptr: 15991 data: 0x86820000 module: 6 information type: 8 information index: 2 MBS data:0000 ts: 0x00000083B96F05A6 0x3444d22 = 54807842 * 40ns = 2192313680ns = 2.2s *re-check* Correlation trigger input OK, pulse width 500ns External clock is 50MHz MACB master mode 6 So ... correlation clock frequency is 25MHz and Correlation DAQ Accepted Trigger not working 18.30 Per PCS request Master MACB clock output 25Mhz reset output not observed at DAQ GO as expected
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Resubmit as new entry
Attachment 1:
20.png
Original size: 1492x1029
Attachment 2:
21.png
Original size: 1492x1029
Attachment 3:
22.png
Original size: 1492x1029
Attachment 4:
23.png
Original size: 1492x1029
Attachment 5:
24.png
Original size: 1492x1029
Attachment 6:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown