AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
AIDA
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Mar 29 12:37:14 2025
Author
*
:
Subject
*
:
From the installation of the RG58 cable for the 50MHz TTL clock from BRIKEN DAQ to AIDA Master MACB external clock input we observe DAQ stalls at c. 06.30 and 18.30 daily. This coincides with the nominal start times of the ORNL Clover detector LN2 fill cycles. run start stop files recovery AIDA Master MACB internal clock R1 28.9.16 15.02 11.20 R1_304 OK RG174 cable from BRIKEN DAQ 50MHz clock (TTL) to AIDA Master MACB external clock input 9.10.16 16.55 17.30 no data transfer, TS_SYNC phase = 0, OK 9.10.16 17.40 19.15 est no data transfer, TS_SYNC phase = 0, ReSYNC 9.10.16 22.20 01.40 no data transfer, TS_SYNC phase = 1, ? 10.10.16 14.20 16.50 no data transfer, TS_SYNC phase = 2, ? 10.10.16 18.35 18.40/19.40 no data transfer, TS_SYNC phase = 3, some FEE64s stopped later than others, ReSYNC 10.10.16 20.36 06.35 no data transfer, TS_SYNC phase = 0, power cycle RG174 cable from BRIKEN DAQ 50MHz clock (TTL) to AIDA Master MACB external clock input replaced by RG58 cable run start stop files recovery R17 11.10.16 15.46 08.22 R17_440 soft reset R21 12.10.16 14.05 15.30 power dip - power cycle R22 12.10.16 16.20 19.05 OK R24 13.10.16 OK R25 13.10.16 OK R26 13.10.16 OK R27 13.10.16 OK R28 13.10.16 OK R29 13.10.16 OK R32 13.10.16 21.20 22.34 R32_26 soft reset R33 14.10.16 00.01 00.25 ? power cycle R40 14.10.16 01.49 06.26 R40_91 soft reset R41 14.10.16 OK R42 15.10.16 22.45 07.18 R42_164 System-wide tests - SYNC errors fail *but* SYNC pulses OK - ReSYNC only R43 15.10.16 11.39 12.43 disk housekeeping caused merger/tapeserver problem R46 15.10.16 12.43 18.26 R46_109 soft reset R47 16.10.16 11.12 18.26 R47_120 power cycle R49 16.10.16 21.05 06.26 R49_226 soft reset R51 17.10.16 12.21 18.30 R51_145 soft reset R52 17.10.16 20.41 06.30 R52_211 soft reset R53 18.10.16 10.02 18.30 R53_193 soft reset R55 18.10.16 18.52 19.17 R55_10 soft reset R60 19.10.16 09.35 16.28 R60_169 OK R61 19.10.16 16.30 18.26 R61_69 power cycle R63 19.10.16 20.05 06.46 R63_291 soft reset R64 20.10.16 09.45 18.25 R64_240 OK - System-wide tests - SYNC errors fail & SYNC pulses fail - other checks OK R65 20.10.16 18.49 19.17 R65_12 power cycle R66 20.10.16 20.02 10.55 R66_396 soft reset auto LN2 fill may have failed, manually selected c. 11.00 R67 21.10.16 14.02 18.26 R67_121 soft reset R68 21.10.16 18.40 18.44 R68_1 soft reset R70 21.10.16 18.53 06.46 R70_315 soft reset R71 22.10.16 10.42 18.25 OK R73 22.10.16 19.07 19.17 R73_4 soft reset R74 22.10.16 19.38 06.31 R74_296 soft reset R76 23.10.16 10.46 11.52 R76_29 merger crashed, soft reset R77 23.10.16 18.50 19.17 disk housekeeping caused merger/tapeserver problem R78 23.10.16 19.47 06.46 R78_291 soft reset R79 24.10.16 11.07 18.46 R79_182 soft reset R80 24.10.16 18.56 19.17 R80_5 DAQ stall, soft reset R81 24.10.16 19.29 06.26 R81_169 soft reset R82 25.10.16 10.22 18.30 R82_125 -> safe state R83 27.10.16 14.35 18.30 R83_125 soft reset R86 27.10.16 20.48 06.26 R86_245 soft reset R87 28.10.16 14.34 18.47 R87_274 soft reset R89 29.10.16 19.10 07.17 R89_102 power cycle soft reset => no FEE64 power cycle Restart merger DAQ STOP System wide checks DAQ RESET & SETUP System-wide checks Disable H & data transfer #1 Restart merger & tapeserver Enable H & data transfer #1
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown