AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
AIDA
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Mar 29 12:26:12 2025
Author
*
:
Subject
*
:
> > From the installation of the RG58 cable for the 50MHz TTL clock from BRIKEN DAQ > to AIDA Master MACB external clock input we observe DAQ stalls at c. 06.30 and > 18.30 daily. This coincides with the nominal start times of the ORNL Clover detector > LN2 fill cycles. > > run start stop files recovery > > AIDA Master MACB internal clock > > R1 28.9.16 15.02 11.20 R1_304 OK > > RG174 cable from BRIKEN DAQ 50MHz clock (TTL) to AIDA Master MACB external clock input > > 9.10.16 16.55 17.30 no data transfer, TS_SYNC phase = 0, OK > 9.10.16 17.40 19.15 est no data transfer, TS_SYNC phase = 0, ReSYNC > 9.10.16 22.20 01.40 no data transfer, TS_SYNC phase = 1, ? > > 10.10.16 14.20 16.50 no data transfer, TS_SYNC phase = 2, ? > 10.10.16 18.35 18.40/19.40 no data transfer, TS_SYNC phase = 3, some FEE64s stopped later than others, ReSYNC > 10.10.16 20.36 06.35 no data transfer, TS_SYNC phase = 0, power cycle > > > RG174 cable from BRIKEN DAQ 50MHz clock (TTL) to AIDA Master MACB external clock input > replaced by RG58 cable > > run start stop files recovery > > R17 11.10.16 15.46 08.22 R17_440 soft reset > > R21 12.10.16 14.05 15.30 power dip - power cycle > R22 12.10.16 16.20 19.05 OK > > R24 13.10.16 OK > R25 13.10.16 OK > R26 13.10.16 OK > R27 13.10.16 OK > R28 13.10.16 OK > R29 13.10.16 OK > > R32 13.10.16 21.20 22.34 R32_26 soft reset > R33 14.10.16 00.01 00.25 ? power cycle > > R40 14.10.16 01.49 06.26 R40_91 soft reset > R41 14.10.16 OK > R42 15.10.16 22.45 07.18 R42_164 System-wide tests - SYNC errors fail *but* SYNC pulses OK - ReSYNC only > R43 15.10.16 11.39 12.43 disk housekeeping caused merger/tapeserver problem > > R46 15.10.16 12.43 18.26 R46_109 soft reset > R47 16.10.16 11.12 18.26 R47_120 power cycle > > R49 16.10.16 21.05 06.26 R49_226 soft reset > > R51 17.10.16 12.21 18.30 R51_145 soft reset > R52 17.10.16 20.41 06.30 R52_211 soft reset > R53 18.10.16 10.02 18.30 R53_193 soft reset > > R55 18.10.16 18.52 19.17 R55_10 soft reset > > R60 19.10.16 09.35 16.28 R60_169 OK > R61 19.10.16 16.30 18.26 R61_69 power cycle > > R63 19.10.16 20.05 06.46 R63_291 soft reset > R64 20.10.16 09.45 18.25 R64_240 OK - System-wide tests - SYNC errors fail & SYNC pulses fail - other checks OK > R65 20.10.16 18.49 19.17 R65_12 power cycle > R66 20.10.16 20.02 10.55 R66_396 soft reset auto LN2 fill may have failed, manually selected c. 11.00 > R67 21.10.16 14.02 18.26 R67_121 soft reset > R68 21.10.16 18.40 18.44 R68_1 soft reset > > R70 21.10.16 18.53 06.46 R70_315 soft reset > R71 22.10.16 10.42 18.25 OK > > R73 22.10.16 19.07 19.17 R73_4 soft reset > R74 22.10.16 19.38 06.31 R74_296 soft reset > > R76 23.10.16 10.46 11.52 R76_29 merger crashed, soft reset > R77 23.10.16 18.50 19.17 disk housekeeping caused merger/tapeserver problem > R78 23.10.16 19.47 06.46 R78_291 soft reset > R79 24.10.16 11.07 18.46 R79_182 soft reset > R80 24.10.16 18.56 19.17 R80_5 DAQ stall, soft reset > R81 24.10.16 19.29 06.26 R81_169 soft reset > R82 25.10.16 10.22 18.30 R82_125 -> safe state > > R83 27.10.16 14.35 18.30 R83_125 soft reset > R86 27.10.16 20.48 06.26 R86_245 soft reset > R87 28.10.16 14.34 18.47 R87_274 soft reset > > R89 29.10.16 19.10 07.17 R89_102 power cycle > > soft reset => no FEE64 power cycle > Restart merger > DAQ STOP > System wide checks > DAQ RESET & SETUP > System-wide checks > Disable H & data transfer #1 > Restart merger & tapeserver > Enable H & data transfer #1
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown