> Original system configuration before my arrival: nnaida11 - 2b:22:6e > nnaida12 - 2b:33:15 > nnaida13 - 2b:09:ce > All on firmware version 0x1900c1f. > > With 8us shaping time and pulser amplitude @ 5V, FWHM [ch] were: > > Ch | nnaida11 | nnaida12 | nnaida13 | nnaida14 > 1.4.L | 38 | 33 | 38 | 34 > 1.6.L | 24 | 25 | 28 | 23 > 1.8.L | 20 | 17 | 17 | 16 > 1.10.L | 21 | 17 | 17 | 16 > > Slightly higher than expected for a few channels, but FWHM fall within ~16-40ch for all channels in all FEEs. > All system checks passed. > > nnaida13/14 kept constant throughout as control. > > (1) Swapped nnaida11/12: nnaida11 -> 2b:33:0c nnaida12 -> 2a:d0:1a > Initially failed SYNC error test - consequence of old firmware version. > Updated firmware from 0x10300c12 to 0x1900c1f. > All system tests passed. > FWHM on 8us shaping time and same pulser settings. > > Ch | nnaida11 | nnaida12 | nnaida13 | nnaida14 > 1.4.L | 37 | 40 | 42 | 35 > 1.6.L | 31 | 28 | 29 | 23 > 1.8.L | 22 | 18 | 15 | 15 > 1.10.L | 23 | 20 | 16 | 15 > > (2) Swapped nnaida11/12: nnaida11 -> 2a:b8:90 nnaida12 -> 2a:b6:45 > Updated firmware from 0x10300c12 to 0x1900c1f. > All system checks passed. > No ASIC temp in nnaida11. > FWHM on 8us shaping time and same pulser settings. > > Ch | nnaida11 | nnaida12 | nnaida13 | nnaida14 > 1.4.L | 40 | 32 | 40 | 34 > 1.6.L | 29 | 25 | 29 | 23 > 1.8.L | 21 | 18 | 17 | 16 > 1.10.L | 21 | 18 | 17 | 16 > > (3) Swapped nnaida11/12: nnaida11 -> 2a:ed:9a nnaida12 -> 2b:11:c5 > Updated firmware from 0x10300c12 to 0x1900c1f. > All system checks passed. > No ASIC temp in nnaida12. > FWHM on 8us shaping time and same pulser settings. > > Ch | nnaida11 | nnaida12 | nnaida13 | nnaida14 > 1.4.L | 44 | 36 | 40 | 35 > 1.6.L | 30 | 27 | 29 | 24 > 1.8.L | 22 | 18 | 16 | 17 > 1.10.L | 23 | 18 | 17 | 16 > > > The above were all the repaired modules and seem to be operating normally. > Following are the 2 modules for which no fault report was provided. I only had time to complete testing on one, the other remains unknown. > > (4) Swapped nnaida11/12: nnaida11 -> 2a:ed:8f nnaida12 -> 2b:09:da > Updated firmware from 0x10300c12 to 0x1900c1f. > nnaida11 failed clock status tests. Tried 'Perform resync' from Master Timestamp window with no effect. > No SYNC errors reported. All other system tests passed. > nnaida12 missing lots of channels but all system checks passed. > FWHM on 8us shaping time and same pulser settings. > > Ch | nnaida11 | nnaida12 | nnaida13 | nnaida14 > 1.4.L | 46 | 46 | 41 | 36 > 1.6.L | 31 | 26 | 28 | 24 > 1.8.L | 22 | 19 | 17 | 16 > 1.10.L | 22 | 20 | 17 | 16 > > > ** > > Overall, the first three modules which have been repaired seem to be operating normally. The fourth seems not be and the last module remains unknown. > Ch 1.4.L displays greater than expected FWHM throughout in all nnaida11/12, but FWHM were largely constant (to within a few channels) throughout and all FWHM fell in the range ~15-40ch apart from 1.1.L in *all* nnaida.
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown