Sat Mar 29 12:28:17 2025
Author
*
:
Subject
*
:
> 10.53 DAQ found stalled > Most recent files R89_102 last accessed 07.17 > > DSSSD bias & leakage current OK - see attachments 1 & 2 > FEE64 temperatures OK - see attachment 3 > > All system wide checks OK *except* Clock status, SYNC errors & SYNC pulses - see attachments 4-8 - unusual > messages/reports > > One merger error messages - link 18 - see attachment 9 > > Restart merger > DAQ STOP OK > DAQ RESET & SETUP OK > ReSYNC OK > All system-wide checks OK > Disable H & data transfer #1 > Restart merger & tapeserver > Enable H & data transfer #1 > > Standard soft reset did not work - one or more FEE64s dropped data transfer #1 link at DAQ GO > > Retry - one, more FEE64s indicate error state - run control tab unresponsive > > Power cycle FEE64s