Entry time:
Sat Mar 29 12:36:49 2025
Author
*
:
Subject
*
:
00.40-02.30 Discussion with PJCS Confirm both NIM bin voltages OK Move master MACB to lower NIM bin (with BNC PB_4, Ortec 433, 2x CAEN N1419B, 1x CAEN N1419) successful ReSYNC system-wide checks clock test fails from zero to all of the following FEE64s - nnaida7, 8, 15 & 16 SYNC count test OK *except* nnaida19 which has greater number of SYNC pulses online analysis indicates nnaida19 ADC data not synchronised with other FEE64s by ~200ms Replace master MACB rev B mode 0 with MACB module #13 mode 5 (external clock 50MHz TTL) Move MACB module 2 from upper NIM bin to lower NIM bin Swap nnaida19/port1 <-> nnaida20/port2 Power cycle FEE64s and restart System wide checks fail - see attachments 1-4 Re-seat HDMI cabling master MACB -> MACB modules 3-6 System wide checks fail - see attachments 7-10 Swap ports of 2x HDMI cables from master MACB Power cycle FEE64s Re_SYNC & system wide checks fail - see attachments 11-15 10.20 ReSYNC fails for all TS_SYNC_PHASE settings 0-3 DK checks MACB mode settings master -> 5 module #2 2 module #3 2 modules #4-11 3 Check HDMI cable seating nnaida6 to master MACB No change - ReSYNC fails, system wide checks fail as before Per PJCS e-mail check MACB settings per https://elog.ph.ed.ac.uk/AIDA/258 and change MACB module # 7 from mode 3 to mode 2. MACB settings are now MACB # 1 2 3 4 5 6 7 8 9 10 11 spare 1 spare 2 Mode 5 2 3 3 3 3 2 3 3 3 3 Rev B y y 50MHz? y *BUT* remember the system has been in the previous state since Elog 258 abd has been working OK No change - ReSYNC fails, system wide checks fail as before Check 50MHz TTL external clock signal and observe transients and width changes in clock signal - see attachment 16 This may not be *the* explanation of current problems but I doubt the the hardware will be 'happy' with it either JAR cycles NIM signal through NIM-TTL signal converter several times to produce better (no transients or width changes) clock signal with c. 3.2V amplitude Power cycle and restart FEE64s No change - ReSYNC and system wide checks fail - see attachments 17-21 12.40 Re-checked HDMI cabling found master MACB port 1 -> MACB #7 next, port 2 -> MACB #3 next change to master MACB port 1 -> MACB #3 next, port 2 -> MACB #7 next Power cycle FEE64s ReSYNC partial failure (left side OK, right side of tree fails), system wide checks fail - see attachments 22-26 13.05 Swap HDMI cables from master MACB to parents, i.e. HDMI cable master port 1 to MACB #3 next changes to master port 2 to MACB #7 next ReSYNC and system wide checks fail - see attachments 30-34
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown