<p>Put the variable Al degraders all back in for safety (was 4.4 mm, now 5.4 mm)</p>
<p>Takechi team switches the condition: F5 empty; F7 CH2; F11 empty</p>
<p> </p>
<p>7:00 Reset Run Control, run Setup, everything looks good. Start the run</p>
<p> Data rate around 10 MB/s</p>
<p>7:04 Checking the online data rate with MIDAS, the event rate is nearly zero...but it comes back (presume Takechi team was playing with the beam condition)</p>
<p>Events come back...</p>
<p>F11 Plastic rate is 1.2kHz</p>
<p>Here is a sample of the offline analysis of event rates with all Al degraders in:</p>
<p> *** DSSSD # 1 count: 640 old count: 321 dt: 1.03 s HEC rate: 309.51 Hz<br />
*** DSSSD # 2 count: 551 old count: 277 dt: 1.03 s HEC rate: 265.85 Hz<br />
*** DSSSD # 3 count: 773 old count: 452 dt: 1.03 s HEC rate: 311.45 Hz<br />
*** DSSSD # 4 count: 633 old count: 371 dt: 1.03 s HEC rate: 254.20 Hz<br />
*** DSSSD # 5 count: 211 old count: 140 dt: 1.03 s HEC rate: 68.89 Hz<br />
*** DSSSD # 6 count: 6 old count: 4 dt: 1.03 s HEC rate: 1.94 Hz</p>
<p>7:11 Remove 1 mm of Al variable degrader (back to 4.4 mm total before AIDA)</p>
<p>Offline rates from R10_3:</p>
<p> *** DSSSD # 1 count: 2596 old count: 2447 dt: 6.52 s HEC rate: 398.43 Hz<br />
*** DSSSD # 2 count: 2193 old count: 2067 dt: 6.52 s HEC rate: 336.58 Hz<br />
*** DSSSD # 3 count: 2641 old count: 2485 dt: 6.52 s HEC rate: 405.34 Hz<br />
*** DSSSD # 4 count: 2626 old count: 2470 dt: 6.52 s HEC rate: 403.04 Hz<br />
*** DSSSD # 5 count: 1940 old count: 1825 dt: 6.52 s HEC rate: 297.75 Hz<br />
*** DSSSD # 6 count: 852 old count: 801 dt: 6.52 s HEC rate: 130.76 Hz</p>
<p>7:18 Leak currents shown as attachments 1 and 2</p>
<p>7:20 Notice that the data rate has gone to zero...</p>
<p> </p>
<p>Follow along with https://elog.ph.ed.ac.uk/AIDA/303 to fix it. This looks good and the merger seems to come back successfully.</p>
<p> </p>
<p>Trying to STOP on Run Control gave:</p>
<p>STATE for nnaida16 returned with an error<br />
error: SOAP http transport timed out after 20000 ms<br />
NONE<br />
error: SOAP http transport timed out after 20000 ms<br />
while executing<br />
"$transport $procVarName $url $req"<br />
(procedure "::SOAP::invoke" line 18)<br />
invoked from within<br />
"::SOAP::invoke ::SOAP::_DataAcquisitionControlClient__GetState"<br />
("eval" body line 1)<br />
invoked from within<br />
"eval ::SOAP::invoke ::SOAP::_DataAcquisitionControlClient__GetState $args"<br />
(procedure "DataAcquisitionControlClient__GetState" line 1)<br />
invoked from within<br />
"DataAcquisitionControlClient__GetState"</p>
<p> </p>
<p>Try a Reset on Run Control (this is the only option at present)</p>
<p> nnaida16 showed "going" but after Reset shows "reset" like all the rest.</p>
<p>Now we get another error</p>
<p>JavaScript error occurred! </p>
<p>Error description: SyntaxError: missing ) after argument list<br />
Page address: http://localhost:8015/DataAcquisitionControl/DataAcquisitionControl.tml<br />
Line number: 203</p>
<p> </p>
<p>nnaida16 shows error</p>
<p> </p>
<p>STATE for nnaida16 returned with an error<br />
connect failed <br />
NONE<br />
connect failed <br />
while executing<br />
"::http::geturl http://nnaida16:8015/DataAcquisitionControlServer -headers {} -type text/xml -timeout 20000 -query {<?xml version="1.0" encoding="UTF-8..."<br />
("eval" body line 1)<br />
invoked from within<br />
"eval [list ::http::geturl $url] $args"<br />
(procedure "::http::geturl_followRedirects" line 4)<br />
invoked from within<br />
"::http::geturl_followRedirects http://nnaida16:8015/DataAcquisitionControlServer -headers {} -type text/xml -timeout 20000 -query {<?xml version="1.0"..."<br />
("eval" body line 1)<br />
invoked from within<br />
"eval ::http::geturl_followRedirects [list $url] -headers [list $local_headers] -type text/xml -timeout $timeout -query [list $request] $local_pro..."<br />
(procedure "::SOAP::Transport::http::xfer" line 61)<br />
invoked from within<br />
"$transport $procVarName $url $req"<br />
(procedure "::SOAP::invoke" line 18)<br />
invoked from within<br />
"::SOAP::invoke ::SOAP::_DataAcquisitionControlClient__GetState"<br />
("eval" body line 1)<br />
invoked from within<br />
"eval ::SOAP::invoke ::SOAP::_DataAcquisitionControlClient__GetState $args"<br />
(procedure "DataAcquisitionControlClient__GetState" line 1)<br />
invoked from within<br />
"DataAcquisitionControlClient__GetState"<br />
GET OPTION for nnaida16 returned with an error<br />
connect failed <br />
NONE<br />
connect failed <br />
while executing<br />
"::http::geturl http://nnaida16:8015/DataAcquisitionControlServer -headers {} -type text/xml -timeout 60000 -query {<?xml version="1.0" encoding="UTF-8..."<br />
("eval" body line 1)<br />
invoked from within<br />
"eval [list ::http::geturl $url] $args"<br />
(procedure "::http::geturl_followRedirects" line 4)<br />
invoked from within<br />
"::http::geturl_followRedirects http://nnaida16:8015/DataAcquisitionControlServer -headers {} -type text/xml -timeout 60000 -query {<?xml version="1.0"..."<br />
("eval" body line 1)<br />
invoked from within<br />
"eval ::http::geturl_followRedirects [list $url] -headers [list $local_headers] -type text/xml -timeout $timeout -query [list $request] $local_pro..."<br />
(procedure "::SOAP::Transport::http::xfer" line 61)<br />
invoked from within<br />
"$transport $procVarName $url $req"<br />
(procedure "::SOAP::invoke" line 18)<br />
invoked from within<br />
"::SOAP::invoke ::SOAP::_DataAcquisitionControlClient__GetOption HistEnable"<br />
("eval" body line 1)<br />
invoked from within<br />
"eval ::SOAP::invoke ::SOAP::_DataAcquisitionControlClient__GetOption $args"<br />
(procedure "DataAcquisitionControlClient__GetOption" line 1)<br />
invoked from within<br />
"DataAcquisitionControlClient__GetOption "$AcqGetOption""<br />
GET OPTION for nnaida16 returned with an error<br />
connect failed <br />
NONE<br />
connect failed <br />
while executing<br />
"::http::geturl http://nnaida16:8015/DataAcquisitionControlServer -headers {} -type text/xml -timeout 60000 -query {<?xml version="1.0" encoding="UTF-8..."<br />
("eval" body line 1)<br />
invoked from within<br />
"eval [list ::http::geturl $url] $args"<br />
(procedure "::http::geturl_followRedirects" line 4)<br />
invoked from within<br />
"::http::geturl_followRedirects http://nnaida16:8015/DataAcquisitionControlServer -headers {} -type text/xml -timeout 60000 -query {<?xml version="1.0"..."<br />
("eval" body line 1)<br />
invoked from within<br />
"eval ::http::geturl_followRedirects [list $url] -headers [list $local_headers] -type text/xml -timeout $timeout -query [list $request] $local_pro..."<br />
(procedure "::SOAP::Transport::http::xfer" line 61)<br />
invoked from within<br />
"$transport $procVarName $url $req"<br />
(procedure "::SOAP::invoke" line 18)<br />
invoked from within<br />
"::SOAP::invoke ::SOAP::_DataAcquisitionControlClient__GetOption Xfer2Enable"<br />
("eval" body line 1)<br />
invoked from within<br />
"eval ::SOAP::invoke ::SOAP::_DataAcquisitionControlClient__GetOption $args"<br />
(procedure "DataAcquisitionControlClient__GetOption" line 1)<br />
invoked from within<br />
"DataAcquisitionControlClient__GetOption "$AcqGetOption""<br />
</p>
<p>TapeServer was still running, so maybe that was a mistake...?</p>
<p> </p>
<p>Power cycle...</p> |