09.50 Run 13 Start
Thick C target (6mm) removed from F11. All variable Al degraders put in place
AIDA settings file: 2016Nov07-23.03.06
Keep alive script updated to current directory.
Output from Tom's Implants.f script
*** DSSSD # 1 count: 6316 old count: 6290 dt: 1.19 s HEC rate: 21.89 Hz
*** DSSSD # 2 count: 5435 old count: 5410 dt: 1.19 s HEC rate: 21.05 Hz
*** DSSSD # 3 count: 6314 old count: 6286 dt: 1.19 s HEC rate: 23.57 Hz
*** DSSSD # 4 count: 5211 old count: 5186 dt: 1.19 s HEC rate: 21.05 Hz
*** DSSSD # 5 count: 1383 old count: 1375 dt: 1.19 s HEC rate: 6.73 Hz
*** DSSSD # 6 count: 67 old count: 66 dt: 1.19 s HEC rate: 0.84 Hz
Measured rates from file:
DSSD1: 309
DSSD2: 270
DSSD3: 308
DSSD4: 249
DSSD5: 67
DSSD6: 3.3
10.03 biases and leakage currents attachments 1 and 2
10.26 Run stopped as Takechi group optimise upstream lowering our rate. |