AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
|
AIDA |
 |
|
Message ID: 443
Entry time: Wed Nov 9 02:14:08 2016
|
Author: |
OH, TD |
Subject: |
NP1412 R14 |
|
|
11.13 Still waiting to get beam back got access so took temp measurement.
T=25.6 DP=0.0 H=18.1
Biases and leakages good. Attachments 1 and 2
11.58 *All* system wide checks OK
14.29 *All* system wide checks OK
start 15:09
stop 16.04
AIDA filename R14
BRIKEN filename 161105_1507
BigRIPS filename run405
ASIC settings 2016Nov07_23.03.06
DSSSD bias & leakage currents ok attachments 3 and 4
Degrader All variable in at start (5.5mm Al)
F11 rate 430Hz
BigRIPS setting 76-78Ni
*** DSSSD # 1 count: 316 old count: 146 dt: 1.02 s HEC rate: 166.21 Hz
*** DSSSD # 2 count: 294 old count: 143 dt: 1.02 s HEC rate: 147.64 Hz
*** DSSSD # 3 count: 396 old count: 233 dt: 1.02 s HEC rate: 159.37 Hz
*** DSSSD # 4 count: 257 old count: 147 dt: 1.02 s HEC rate: 107.55 Hz
*** DSSSD # 5 count: 43 old count: 28 dt: 1.02 s HEC rate: 14.67 Hz
*** DSSSD # 6 count: 3 old count: 1 dt: 1.02 s HEC rate: 1.96 Hz
15.24 Briefly reduce Al degrader from 5.4mm Al to 3.2mm Al
Observe increased rate in DSSSDD #6, similar rates in DSSSD #1 and increased
rates in AIDA plastic veto
15.26 Return to 5.4mm Al degrader
16.06 *All* system wide checks OK |
|
|
|
|
|
|
|
|