AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
AIDA
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Mar 29 11:17:06 2025
Author
*
:
Subject
*
:
> start 18.55 10.11.16 > stop > AIDA filename R26_0 > BRIKEN filename 161109_1852_767778Ni_045 > BigRIPS filename 443 > ASIC settings 2016Nov07_23.03.06 > DSSSD bias & leakage currents OK attachments 1 and 2 > > Degrader all degraders out > F11 rate 430Hz > BigRIPS setting 767778Ni F5 out, F7 CH2 in, F11 6mm C in > > From offline analysis of R26_2 > > *** DSSSD # 1 count: 459 old count: 225 dt: 1.02 s HEC rate: 229.83 Hz > *** DSSSD # 2 count: 385 old count: 191 dt: 1.02 s HEC rate: 190.54 Hz > *** DSSSD # 3 count: 461 old count: 228 dt: 1.02 s HEC rate: 228.85 Hz > *** DSSSD # 4 count: 403 old count: 197 dt: 1.02 s HEC rate: 202.33 Hz > *** DSSSD # 5 count: 218 old count: 121 dt: 1.02 s HEC rate: 95.27 Hz > *** DSSSD # 6 count: 87 old count: 42 dt: 1.02 s HEC rate: 44.20 Hz > > 19.02 FEE64 temperature OK - see attachment 3 > > 19.16 BRIKEN DAQ problems following restart - multiple correlation scaler reset requests issued - ignore data > before R26_5 > New BRIKEN data file 161109_1852_767778Ni_046 > > 19.20 AIDA DAQ stalled (presumably *end* of LN2 fill cycle) > > Soft reset OK > Clock lock state status 0xd - see attachment 6 > > 19.29 Start DAQ (R27) > > 19.35 BRIKEN DAQ problems starting SyncCheck program - - multiple correlation scaler reset requests issued - > ignore data before R27_2 > > 19.37 All degraders (5.4mm Al) in for new Takechi et al. setting > BigRIPS setting 767778Ni F5 in, F7 out, F11 6mm C in > > BRIKEN filename 161109_1852_767778Ni_045 > AIDA fileame R27_3 > BigRIPS filename 444 > > 19.40 All degraders out > > DSSSD bias & leakage currents OK attachments 4 & 5 > > From offline analysis of R27_4 > > *** DSSSD # 1 count: 281 old count: 247 dt: 2.31 s HEC rate: 121.43 Hz > *** DSSSD # 2 count: 247 old count: 219 dt: 2.31 s HEC rate: 106.74 Hz > *** DSSSD # 3 count: 286 old count: 252 dt: 2.31 s HEC rate: 123.59 Hz > *** DSSSD # 4 count: 287 old count: 253 dt: 2.31 s HEC rate: 124.02 Hz > *** DSSSD # 5 count: 201 old count: 178 dt: 2.31 s HEC rate: 86.86 Hz > *** DSSSD # 6 count: 33 old count: 29 dt: 2.31 s HEC rate: 14.26 Hz > > 20.36 Noted x4 increase in F11 rate to c. 2kHz > All degraders in (5.4mm Al) > > BRIKEN DAQ shows x4-5 increase for c. 6 minutes > DSSSD bias & leakage currents OK attachments 7 & 8
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown