<p>24/02/15</p>
<p>1200: Update the FEE firmware on nnaida1-16 without problem.</p>
<p> Gone from file FEE_Oct12_27Nov13.bin ----> FEE_Riken_Apr14_24.bin</p>
<p> Included are a screen shot of the temperature window showing the new firmware versions and a stats screen.</p>
<p> </p>
<p>12.15 Update MIDAS DAQ software</p>
<p> su</p>
<p> cp -r /MIDAS@aiidas /MIDAS@aidas.240214 ( /MIDAS is a link to /MIDAS@aidas )</p>
<p> exit</p>
<p> </p>
<p> cd <update directory></p>
<p> cp -r Data_Acq /MIDAS</p>
<p> cp -r Merger /MIDAS</p>
<p> cp -r TclHttpd /MIDAS</p>
<p> </p>
<p> New versions of merge64.AD and master64 were installed in /MIDAS/Merger but the process crashed at startup</p>
<p> with multiple messages of the type:</p>
<p> MIDAS Data Link (12345) : Received SEGV signal; exiting.</p>
<p> (see attachment 3)</p>
<p> </p>
<p> Is this related to the recent changes to the MIDAS TapeServer software to resolve problems with MIDAS Data</p>
<p> libraries libdataspy.so and libxfer.so ?</p>
<p> </p>
<p> As a temporary workaround I have copied the backups of merge64.AD and master64 back to the install</p>
<p> directory /MIDAS/Merger. With the old verison of the merger we continue to obtain error messages</p>
<p> (see attachments 4-8)</p>
<p> </p> |