A draft 'to do' list in preparation for further AIDA tests at RIKEN from mid-April.
Please feel free to add your comments, suggestions, other items etc.
High Priority
- [VP] fix problem with new merger program which crashes (SEGV) at startup
see https://elog.ph.ed.ac.uk/AIDA/48
- [PCS/Edinburgh] fit 4x AIDA FEE64 PSUs with LCR filters and return to RIKEN
- [PM] transfer AIDA support assembly from original base to new RIKEN F11 base
Medium Priority
- [VP] TapeServer 'no storage' mode should not create files (cf. MIDAS VME DAQ TapeServer behaviour) ... ?
- [VP] TapeServer should check for existence of file before opening new file
(and possibly overwriting an existing file) as a workaround for umode 022 file perms
- [VP] Define robust procedure for starting/stopping MIDAS DAQ/Merger/TapeService
- [VP/PCS] Critically review data synchronisation methodology
see https://elog.ph.ed.ac.uk/BRIKEN/5 and https://elog.ph.ed.ac.uk/BRIKEN/6
Low Priority
- [Edinburgh] modify USB ac mains switches - relays default to off state - ship to RIKEN
- [Edinburgh] purchase 3x 3TB SATA disks for installation in aidas1 |