Entry time:
Sat Mar 29 11:35:41 2025
Author
*
:
Subject
*
:
10.35 DAQ continues OK Current file May2017/R19_253 ASIC settings 2017Mar27-16.12.39 *except* slow comparator 0x0a LEC/MEC fast comparator 0xff Detector biases; leakage currents OK - see attachment 1 FEE64 Temperatures OK - see attachment 2 good events; statistics OK - see attachment 3 No warnings/errors reported by merger since DAQ GO - see attachment 4 *all* system wide checks OK *except* ADC calibration of nnaida7 10.38 E17/F11 ambient temperature +24.7 deg C, RH 40.7%, d.p. +10.7 deg C Julabo FL11006 set point +20 deg C, actual +20.0 deg C, water level OK (c. 75%) 10.39 DAQ stops OK Current file May2017/R19_253 Deleted R19* ASIC settings 2017Mar27-16.12.39 *except* slow comparator 0x0a LEC/MEC fast comparator 0xff BNC PB-4 settings Amplitude 90,000 x5 attenuator IN t_r 50ns, tau_d 50us polarity - rate 250Hz range delay MIN, tail pulse Check ASIC Control x2 Zero all spectra 10.47 DAQ starts File May2017/R20 Ras Pi system console logs for USB0 attached - see attachment 5 Analysed R20_0. All appears to be working fine. Highest dead time ~0.3% - see attachment 6 Off-line analysis of R20_0 confirms ADC data and discriminator are synchronised - see attachments 7,8,9 16.55 DAQ continues OK Current file May2017/R20_71 ASIC settings 2017Mar27-16.12.39 *except* slow comparator 0x0a LEC/MEC fast comparator 0xff Detector biases; leakage currents OK - see attachment 10 FEE64 Temperatures OK - see attachment 12 good events; statistics OK - see attachment 13 No warnings/errors reported by merger since DAQ GO - see attachment 14 *all* system wide checks OK *except* ADC calibration of nnaida7 17.02 E17/F11 ambient temperature +24.0 deg C, RH 40.3%, d.p. +9.7 deg C Julabo FL11006 set point +20 deg C, actual +20.0 deg C, water level OK (c. 75%) 17.03 DAQ stops OK Current file May2017/R20_73 Deleted R20* ASIC settings 2017Mar27-16.12.39 *except* slow comparator 0x0a LEC/MEC fast comparator 0xff BNC PB-4 settings Amplitude 90,000 x5 attenuator IN t_r 50ns, tau_d 50us polarity - rate 250Hz range delay MIN, tail pulse Check ASIC Control x2 Zero all spectra 17.08 DAQ starts File May2017/R21 Raspberry Pi system console logs for USB0 attached - see attachment 15 17.50 Changed permissions of options files /MIDAS/DB/EXPERIMENTS/Options/nnaida<n>/CONTENTS from mode 644 to mode 777 18.09 DAQ stops OK Current file May2017/R21_11 Deleted R21* ASIC settings 2017Mar27-16.12.39 *except* slow comparator 0x0a LEC/MEC fast comparator 0xff BNC PB-4 settings Amplitude 90,000 x5 attenuator IN t_r 50ns, tau_d 50us polarity - rate 250Hz range delay MIN, tail pulse DAQ RESET DAQ SETUP *all* system wide checks OK *except* nnaida7, 9, 13 and 22 ADC calibration failed Check ASIC Control x2 17.08 DAQ starts File May2017/R22 Raspberry Pi system console logs for USB0 attached - see attachment 16
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown