AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
AIDA
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Mar 29 12:25:35 2025
Author
*
:
Subject
*
:
> 00:05 BigRIPS and BRIKEN stop their daqs > AIDA currently on file R1_312 > > 00:06 BRIKEN start run 23 > BigRIPS start run 1024 > AIDA on file R1_312 > > System wide checks all ok > > 01:05 BigRIPS and BRIKEN stop their daqs > AIDA on file R1_327 > > 01:06 BigRips Start run 1025 > BRIKEN start run 24 > AIDA file R1_327 > > System wide checks all ok > > 02:02 BigRIPS and BRIKEN stop their daqs > AIDA on file R1_341 > ASIC load check ok > > 02:03 BigRIPS start run 1026 > BRIKEN start run 25 > AIDA ON FILE R1_341 > > 02:11 System wide checks all ok > Leakages and bias ok (Leakages rising again though) - attachment 1 > FEE temperatures ok - attachment 2 > Good event statistics - attachment 3 > Merger and tape server still running - attachment 4 > > 02:23 Beam is off. Will recover soon > > 02:26 Beam is back > > 02:27 beam stopped again > > 02:28 beam back > > 02:37 Since beam has come back we appear to have lost all implant channels. > only seeing events in DSSD2 > > 03:30 ASIC load issue resolved. AIDA data should be good from R1_353 > > Beam continues to turn off and on > > 03:52 Since ~2am beam has been passing through the dssd > Implantation spectrum - attachment 5 > Upon investigation the fixed degrader had fallen on the left and was at a 30 degree angle. > It has now been put back in position > AIDA file when fixed R1_360 > BRIKEN reset the timestamp > Whilst sorting the ASIC issue bigRips moved onto run 1029 > BRIKEN run 1028. Full details in their elog > > 03:55 briken and bigRIPS stop runs > bigRIPS start run 1028 > BRIKEN run 27 > AIDA file R1_360 > > 04:29 Implant hit spectra after the degrader was replaced - attachment 6 > > 04:58 BigRIPS and BRIKEN stop daqs > AIDA on file R1_376 > > 04:59 BigRIPS starts file 1029 > BRIKEN starts run 28 > AIDA at very end of file R1_376 > > 05:20 System wide checks ok > bias and leakage currents ok - attachment 7 > > 05:26 Beam still dropping out for short moments of time > > 06:03 BigRips and BRIKEN stop their runs > AIDA on file R1_393 > > 06:04 BRIKEN start run 29 > BigRIPS start run 1030 > AIDA on file R1_393 > > 06:28 Beam lost > > 06:31 Beam returned > > 06:46 System wide checks ok > FEE temperatures ok - attachment 8 > > 07:01 BigRIPS and BRIKEN stop their runs > AIDA on file R1_407 > > 07:02 BRIKEN start run 30 > BigRips run 1031 > AIDA on file R1_407 > > 07:31 system wide checks all ok > > 07:48 Bias and leakage currents ok - attachment 9 > > 08:01 Briken and BIgRips End current runs > AIDA file R1_422 E silicon detector has saturation problem (see the attachment). We lower the > gain in round factor of 2.
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown