Message ID: 617
Entry time: Wed May 31 08:00:26 2017
|
Author: |
NN, CB |
Subject: |
Wednesday 31 May 16:00 - 24:00 |
|
|
16:30 Check online data ok (R1_533) see attachment 1
16:39 BigRips and BRIKEN stop their runs
AIDA on file R1_550
16:43 Beam is off
16:47 All degraders completely removed
Beam on
current AIDA run R1_551
16:48 BRIKEN start run 40
BigRIPS start run 1041
AIDA on file R1_551
16:57 BigRIPS and BRIKEN stop their runs
AIDA on file R1_554
high energy correlation between x and y attachment 2
16:57 Beam is off
Degrader back to its place, thickness 14 mm
17:00 Checked chiller level - 50%
17:01 Beam is on
17:02 BRIKEN start run 41
BigRIPS start run 1042
AIDA on file R1_555
17:16 FEE's temperature normal
statistics normal
system wide checks ok
leakage current and bias ok see attachment 3
merger and tapeserver ok
17:17 high energy correlation between x and y attachment 4
current AIDA run R1_558
18:02 Beam is off
current AIDA file Run R1_570
BigRIPS and BRIKEN stop their runs
RH = 41.3%, T=24.3 C, DP=10.3 C
Degrader now 5 (in F7) + 6 (in F11) + 3 (in F11) = 14 mm
Refilled chiller - >95%
18:42 Beam is on
18:57 The optimization of beam tuning is going on
19:20 Optimization of beam done
19.28 BRIKEN start run 42
BigRIPS start run 1053
AIDA on file R1_588
BNC PB-4
Amplitude 90,000
x5 attenuator IN
t_r 100ns tau_d 50us
- polarity
frequency 25Hz range
delay MIN, tail pulse, INT ref
ASIC settings 2017Mar27-16.12.39
84Zn degrader setting - 5mm (in F7) + 6mm (in F11) + 3mm (in F11) = 14 mm
19.41 Detector biases; leakage currents OK - see attachments 5 & 6
FEE64 Temperatures OK - see attachment 7
good events statistics OK - see attachment 8
No warnings/errors reported by merger since DAQ GO - see attachment 9
*all* system wide checks OK *except* ADC calibration of nnaida1, 21 and nnaida1 clock status (status=6)
20.19 DAQ stops
AIDA file RIBF127R1/R1_601
analysis of R1_601 dead time <0.5% - see attachment 10
online analysis - ADC data synchronised - see attachment 12
online analysis per FEE64 HEC x versus y - attachment 11 mid-run - all SortSas spectra cleared -
attachment 13 end of run
why does x-y distribution appear to change?
distributions centred OK but now broader in x
20.20-20.39 various variable degrader settings to establish approximate degrader setting for 78Ni
20.39 BRIKEN start run 44
BigRIPS start run 1054
AIDA on file R1_606
78Ni degrader setting (to be checked) 5mm Al (fixed F7) + 9mm Al (fixed F11) + 1mm Al (variable F11) = 15mm Al
Offline sort of R1_602 for rates
*** DSSSD # 1 count: 156234 old count: 115866 dt: 1.04 s LEC rate: 38664.03 Hz
*** DSSSD # 2 count: 205986 old count: 152716 dt: 1.04 s LEC rate: 51021.42 Hz
*** DSSSD # 3 count: 72980 old count: 54270 dt: 1.04 s LEC rate: 17920.23 Hz
*** DSSSD # 4 count: 63677 old count: 45811 dt: 1.04 s LEC rate: 17111.86 Hz
*** DSSSD # 5 count: 24253 old count: 17204 dt: 1.04 s LEC rate: 6751.45 Hz
*** DSSSD # 6 count: 48843 old count: 34242 dt: 1.04 s LEC rate: 13984.68 Hz
*** DSSSD # 1 count: 75 old count: 52 dt: 1.04 s HEC rate: 22.03 Hz
*** DSSSD # 2 count: 114 old count: 82 dt: 1.04 s HEC rate: 30.65 Hz
*** DSSSD # 3 count: 118 old count: 78 dt: 1.04 s HEC rate: 38.31 Hz
*** DSSSD # 4 count: 107 old count: 67 dt: 1.04 s HEC rate: 38.31 Hz
*** DSSSD # 5 count: 54 old count: 30 dt: 1.04 s HEC rate: 22.99 Hz
*** DSSSD # 6 count: 4 old count: 4 dt: 1.04 s HEC rate: 0.00 Hz
20.50 all online histograms zero'd
21:21 analysed run from R1_588 to R1_601, couldn't find any timewraps.
21:41 BigRips and BRIKEN stop their runs
AIDA on file R1_620
21:44 BRIKEN start run 45
BigRIPS start run 1055
AIDA on file R1_621
22:04 FEE's temperature normal
statistics normal
system wide checks ok
leakage current and bias ok see attachment 14
merger and tapeserver ok
22:41 BigRips and BRIKEN stop their runs
AIDA on file R1_634
22:43 BRIKEN start run 46
BigRIPS start run 1056
AIDA on file R1_635
Offline sort of R1_635 for rates
*** data items: 3524688 ( 108739.47 Hz)
*** ADC events: 372675 ( 11497.32 Hz)
*** time warps: 0 ( 0.00 Hz)
*** DSSSD # 1 count: 160274 old count: 151136 dt: 3.43 s LEC rate: 46708.84 Hz
*** DSSSD # 2 count: 216907 old count: 205441 dt: 3.43 s LEC rate: 63213.47 Hz
*** DSSSD # 3 count: 74841 old count: 71214 dt: 3.43 s LEC rate: 21811.00 Hz
*** DSSSD # 4 count: 67870 old count: 63212 dt: 3.43 s LEC rate: 19779.44 Hz
*** DSSSD # 5 count: 25688 old count: 23773 dt: 3.43 s LEC rate: 7486.28 Hz
*** DSSSD # 6 count: 52420 old count: 48302 dt: 3.43 s LEC rate: 15276.82 Hz
*** DSSSD # 1 count: 73 old count: 69 dt: 3.43 s HEC rate: 21.27 Hz
*** DSSSD # 2 count: 137 old count: 131 dt: 3.43 s HEC rate: 39.93 Hz
*** DSSSD # 3 count: 141 old count: 130 dt: 3.43 s HEC rate: 41.09 Hz
*** DSSSD # 4 count: 141 old count: 130 dt: 3.43 s HEC rate: 41.09 Hz
*** DSSSD # 5 count: 47 old count: 41 dt: 3.43 s HEC rate: 13.70 Hz
*** DSSSD # 6 count: 9 old count: 9 dt: 3.43 s HEC rate: 2.62 Hz
23:20 Check online data ok (R1_642) see attachment 15
23:54 BigRips and BRIKEN stop their runs
AIDA on file R1_652
*************June 1st**********
00:03 BRIKEN start run 47
BigRIPS start run 1058
AIDA on file R1_654
BigRIPS not sending synchronizing pulse
00:09 BigRIPS and BRIKEN stop their run |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|