16:26 DAQ continues OK
all system wide checks ok, *except* nnaida1 clock status (6), nnaida1, 21 ADC calibration
Leakage currents OK - attachment 1
FEE64 temperatures OK - attachment 2
Good event statistics OK - attachment 3
No new merger errors - attachment 4
Sorted run R1_1540. DSSSD rates as follows
*** data items: 8958582 ( 115623.74 Hz)
*** ADC events: 954672 ( 12321.45 Hz)
*** time warps: 0 ( 0.00 Hz)
*** DSSSD # 1 count: 392147 old count: 361510 dt: 8.78 s LEC rate: 44646.94 Hz
*** DSSSD # 2 count: 557051 old count: 514085 dt: 8.78 s LEC rate: 63421.69 Hz
*** DSSSD # 3 count: 185346 old count: 172449 dt: 8.78 s LEC rate: 21102.12 Hz
*** DSSSD # 4 count: 154380 old count: 142180 dt: 8.78 s LEC rate: 17576.56 Hz
*** DSSSD # 5 count: 67195 old count: 62386 dt: 8.78 s LEC rate: 7650.32 Hz
*** DSSSD # 6 count: 131951 old count: 122163 dt: 8.78 s LEC rate: 15022.96 Hz
*** DSSSD # 1 count: 185 old count: 171 dt: 8.78 s HEC rate: 21.06 Hz
*** DSSSD # 2 count: 450 old count: 410 dt: 8.78 s HEC rate: 51.23 Hz
*** DSSSD # 3 count: 379 old count: 351 dt: 8.78 s HEC rate: 43.15 Hz
*** DSSSD # 4 count: 297 old count: 269 dt: 8.78 s HEC rate: 33.81 Hz
*** DSSSD # 5 count: 132 old count: 127 dt: 8.78 s HEC rate: 15.03 Hz
*** DSSSD # 6 count: 20 old count: 19 dt: 8.78 s HEC rate: 2.28 Hz
Pulser event still synchronised - see attachment 5
16:34 BigRIPS & BRIKEN stop runs
AIDA on file R1_1542
16:35 BigRIPS starts run 1120
BRIKEN starts run 109
AIDA on file R1_1543
Zero'd all SortSas
17:33 bigRIPS and BRIKEN stop daqs
AIDA on file R1_1556
17:34 bigRIPS starts run 1121
BRIKEN starts run 110
AIDA on file R1_1556
17:54 System wide checks all ok
19:50 bigRIPS starts run 1123
BRIKEN starts run 112
AIDA on file R1_1588
21:00 End of 78Ni run
last AIDA file R1_1606
Stopped AIDA DAQ
Refilled chiller
21:18 Performing pulser walkthrough.
Mistakenly started Tape server before starting DAQ. There will be no R2 run.
Starting R3 - pulser walkthrough.
Pulser frequency 250 Hz
Pulser amplitudes 90 000, 80 000, 70 000 ... 10 000
Can't see pulser peak in spectra. Issue unclear
21:40 Restarted high-amplitude pulser walkthrough run. Run RIBF127R1/R4_0
Pulser frequency 250 Hz
Pulser amplitudes 90 000, 80 000, 70 000 ... 10 000
Pulser peak now visible in histograms
Started low-amplitude pulser walkthrough run. Run RIBF127R1/R5_0
Pulser frequency 250 Hz
Pulser amplitudes 12 000, 10 000, ... 2 000
Set pulser amplitude back to 90 000, frequency to 25 Hz
23:17 Merger and Tape Server stopped
Links to FEEs disabled
All Browser tabs closed
Terminal sessions closed
23:25 Started R1 in /TapeData/RIBF128/
23:43 Start ASIC data readout
System wide checks ok
ASIC load check ok |