Sat Mar 29 12:28:25 2025
Author
*
:
Subject
*
:
> 7 June 2017 > > 00:05 All system-wide checks are passed > Sync pulses nera 44 x 10^6 > Memory 35k ~ 38k > Biases uploaded as 33.png, 34.png - attachments 1 & 2 > Entered into spreadsheet > SSD 3 bias is going up slowly since this isotope setting began > Around "2 to 4" Hz in SSDs 3 and 4 -> 50 to 80 pps implant rate > See attachment 3, 35.png > All rates under 100k except nnaida 13, 21 > See attachment 4, 36.png > FEE temperatures shown as 37.png, attachment #5 > > 00:30 BRIKEN number 32, AIDA R6_299, BigRIPS 3032 > > 01:01 Timewarps look okay (only 2 MBS seen in FEE 6) > See R6_307 - attachment #6 > > 01:30 BRIKEN and BigRIPS runs stopped. AIDA R6_317 at that time. > > 01:31 AIDA R6_318, BRIKEN run #33, BigRIPS #3033 > > All system-wide checks passed. > SYNC pulses 46 x 10^6 > Memory 35 ~ 39k > > 02:08 Biases shown as 38.png, attachment #7 > > 02:34 AIDA run R6_337 when BRIKEN and BigRIPS runs are stopped. > > AIDA passes all system-wide checks. > > 02:37 AIDA just begins R6_338l. BRIKEN run #34, BigRIPS #3034 > > Timewarps look okay, see attachment #8, R6_336 > Statistics consistent, see attachment #9, 39.png > Implant rate around 75 cps > > 03:31 AIDA run R6_354 at the stop of BRIKEN and BigRIPS runs > > > 03:34 AIDA R6_355, BRIKEN run #35, BigRIPS #3035 > > AIDA passed all system checks. Merger shows low rate for nnaida8, but this is consistent for tonight. > > 4:03 Biases shown as 40.png, attachment #10. > > 4:08 Stats shown as 41.png, attachment #11 > As before, only nnaida13 and nnaida21 show over 100k, and nnaida8 is quite low. > > 4:30 AIDA run R6_372 at the close of BRIKEN and BigRIPS runs. > > 4:32 AIDA R6_373 with new BRIKEN run #36 and BigRIPS #3036. > All system-wide checks okay. > > 5:38 AIDA R6_393 at the stop of BRIKEN and BigRIPS runs > All system-wide checks okay. > > 5:39 AIDA still R6_393, BRIKEN run #37 and BigRIPS run #3037 > > 6:00 Leak currents shown as 42.png, attachment #12 > > 6:16 Beam stopped so we can check the signal of one Ge detector that became noisy > R6_404 at that time > Added some Al foil to the Ge signal cables > > 6:28 Beam is back R6_408 > > 6:29 BRIKEN run #41, BigRIPS #38 > > 7:28 AIDA R6_426 at stop of other runs > System-wide checks are okay. > > 7:30 AIDA R6_427. BRIKEN #42, BigRIPS #39 > Implant rates 60 ~ 70 cps in AIDA > One MBS timewarp in R6_426, as attachment #13 > > 7:57 Leak currents shown as attachment #14, 43.png
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown