AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
AIDA
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Mar 29 12:37:09 2025
Author
*
:
Subject
*
:
08:12 Analysis of file RIBF128/R6_438 - zero timewarps, four MBS timewarps - see attachment 1 08:23 Online analysis (per DSSSD rates) of R6_443, see attachment 2 08:35 BigRIPS and BRIKEN stop their DAQ AIDA run file R6_446 08:40 BRIKEN starts run 043 BigRIPS starts run 3040 AIDA on file R6_448 09:16 *All* system wide checks OK FEE64 Temperatures OK - see attachment 3 Good events statistics OK - see attachment 4 Detector biases & leakage currents OK - see attachment 5 Merger and tape server running - see attachment 6,7 09:51 Beam is OFF, RC is down 09:53 BigRIPS and BRIKEN stop their DAQ AIDA run file R6_470 10:00 Beam is ON 10:01 BRIKEN starts run 044 BigRIPS starts run 3041 AIDA on file R6_472 10:07 AIDA DAQ crashed (fuse blown) AIDA on file R6_474 10:14 BigRIPS and BRIKEN stop their QAD AIDA on file R6_474 10:25 E17/F11 ambient temperature +24.3 deg C, RH 42.7%, d.p. +10.9 deg C Julabo FL11006 set point +20 deg C, actual +20.0 deg C, water level OK (c. 75%) BNC PB-4 analogue output BNC T replaced by BNC-Lemo00 adaptor and Lemo00 T 11:08 AIDA DAQ running (recovered) 11:10 BRIKEN starts run 045 BigRIPS starts run 3043 AIDA on file R7_1 (BigRIPS run 3042 was used to check synchronization) 11:21 *All* system wide checks OK FEE64 Temperatures OK - see attachment 8 Good events statistics OK - see attachment 9 Detector biases & leakage currents OK - see attachment 10 Merger and tape server running - see attachment 11,12 11:28 Analysis of file RIBF128/R7_4 - zero timewarps, two MBS timewarps - see attachment 13 12:13 BigRIPS and BRIKEN stop their DAQ AIDA run file R7_16 12:13 BRIKEN starts run 046 BigRIPS starts run 3044 AIDA on file R7_17 12:21 Analysis of file RIBF128/R7_15 - zero timewarps, two MBS timewarps - see attachment 14 12:23 High Energy Correlation spectra - see attachment 15 AIDA on file R7_20 13.00 Detector biases & leakage currents OK - see attachments 16 & 17 FEE64 Temperatures OK - see attachment 18 good events statistics OK - see attachment 19 No warnings/errors reported by merger since DAQ GO - see attachment 20 *all* system wide checks OK 13.06 analysis of file RIBF128/R7_30 - dead time < 0.5%, 0 ts & 1 MBS timewarps - see attachment 21 13.10 online analysis - ADC data synchronised - see attachment 22 per DSSSD HEC x versus y spectra - see attachment 23 per DSSSD HEC E_p versus E_n spectra - see attachment 24 13.12 per DSSSD rates file RIBF128/R7_33 *** DSSSD # 1 count: 100283 old count: 52419 dt: 1.00 s LEC rate: 47699.10 Hz *** DSSSD # 2 count: 143318 old count: 73956 dt: 1.00 s LEC rate: 69123.04 Hz *** DSSSD # 3 count: 61925 old count: 31310 dt: 1.00 s LEC rate: 30509.53 Hz *** DSSSD # 4 count: 42834 old count: 21364 dt: 1.00 s LEC rate: 21396.03 Hz *** DSSSD # 5 count: 10974 old count: 5692 dt: 1.00 s LEC rate: 5263.80 Hz *** DSSSD # 6 count: 29846 old count: 15307 dt: 1.00 s LEC rate: 14488.91 Hz *** DSSSD # 1 count: 3 old count: 1 dt: 1.00 s HEC rate: 1.99 Hz *** DSSSD # 2 count: 34 old count: 23 dt: 1.00 s HEC rate: 10.96 Hz *** DSSSD # 3 count: 96 old count: 51 dt: 1.00 s HEC rate: 44.84 Hz *** DSSSD # 4 count: 85 old count: 51 dt: 1.00 s HEC rate: 33.88 Hz *** DSSSD # 5 count: 8 old count: 4 dt: 1.00 s HEC rate: 3.99 Hz *** DSSSD # 6 count: 8 old count: 4 dt: 1.00 s HEC rate: 3.99 Hz all SortSas spectra & histograms zero'd 13.13 DAQ stop AIDA run file R7_33 13.15 BRIKEN starts run 47 BigRIPS starts run 3045 *** N.B. by mistake BRIKEN DAQ not actually started *** AIDA on file R7_ 33 BNC PB-4 Amplitude 90,000 x5 attenuator IN t_r 100ns tau_d 50us - polarity frequency 25Hz range delay MIN, tail pulse, INT ref ASIC settings 2017Mar27-16.12.39 84Zn BigRIPS setting, 130Ag degrader setting - 2mm Al (in F7) + 3mm fixed + 1mm variable (in F11) = 6 mm Al 13.23 Beam stop to fix problem with STQ DAQ stop AIDA file RIBF128/R7_35 14:00 Beam is ON AIDA file R7_43 14:01 BRIKEN starts run 48 BigRIPS starts run 3046 AIDA on file R7_ 44 14:48 Detector biases & leakage currents OK - see attachment 25 14:56 *All* system wide checks OK FEE64 Temperatures OK - see attachment 26 Good events statistics OK - see attachment 27 Merger and tape server running - see attachment 28,29 15:16 BigRIPS and BRIKEN stop their DAQ AIDA run file R7_64 15:25 Analysis of file RIBF128/R7_60 - zero timewarps, zero MBS timewarps - see attachment 30
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown