00:05 Shift change. Primary beam current ~4800 enA, 238U^86+ so 50 to 60 pnA. Biases shown as attachment #1, 08JunBias1.png Analysis of R7_176 as attachment #2, 08 JunStats1.txt 3 MBS timewarps seen, no global timewarps Implant rate is low, maybe 5 to 10 cps at AIDA All system-wide checks are passed. Sync pulses about 50% of last night, 18 x 10^6 because of run restart at 10:00 FEE64 memory consistent, about 36k ~ 39k 00:35 AIDA at R7_183 when runs stopped. 00:36 AIDA still R7_183 when runs starts: BRIKEN #57, BigRIPS: #3059 01:14 Statistics shown as attachment #3, 08JunStats.png 1:32 AIDA R7_195 at stop of runs 1:33 AIDA R7_196, BRIKEN #58, BigRIPS #3060 System wide checks all okay. 2:01 Operators called: RF is down. It should be recovered in a short time. AIDA R7_202 at that time. Biases and leak currents as attachment #4, 08JunBias2.png 2:07 Beam is back. AIDA R7_203 at that time 2:29 Biases shown as attachment #5, 8JunBias2.png Analysis of R7_207 as attachment #6,analysis_R7_207.txthon 4 MBS timewarps seen, no global timewarps All system-wide checks are passed. (Beam was stopped for a couple minutes here) 2:38 AIDA R7_210 at run change-over 2:39 AIDA R7_210 (same); BRIKEN #59, BigRIPS #3061 All system wide checks are passed, with similar information as before. FEE temps look okay, see attachment #7, 08JunTemp1.png 3:30 AIDA R7_221 at run change-over All system-wide checks are passed 3:31 AIDA R7_221, BRIKEN #60, BigRIPS #3061 3:59 Phone rings, AIDA R7_228 RF drops again 4:03 Beam is back, AIDA R7_228 still 4:34 Biases and leak currents shown as attachment #8, 08JunBias3.png R7_236 at AIDA just began during the changeover 4:38 AIDA R7_236 still, BRIKEN run #61, BigRIPS run #3062 All system wide checks are passed. Analysis shown as R7_235.txt attachment #9 No timewarps, no MBS timewarps 5:30 AIDA R7_247 at changeover All system-wide checks are passed 5:51 AIDA R7_252 NB: BRIKEN and AIDA are not synchronized 5:58 AIDA R7_253, BRIKEN #62; BigRIPS #3066 Now they are synchronized 6:11 Biases and leak currents shown as 08JunBias4.png, attachment #10 7:05 AIDA R7_268 at run changeover All system wide checks are passed as normal Now BRIKEN #63; BigRIPS 3067 Statistics shown as attachment #11 08JunStats2.png Warp data shown as attachment #12 R7_268.txt no warps, no MBS warps 8:00 Biases and leak currents shown as 08JunBias5.png, attachment #13 R7_280 at run changeover BRIKEN #64; BigRIPS #3067
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown