Entry time:
Sat Mar 29 11:35:38 2025
Author
*
:
Subject
*
:
14.16 DAQ running OK - data transfer not enabled BNC PB-4 Amplitude 90,000 x5 attenuator IN t_r 100ns tau_d 50us - polarity frequency range 25Hz delay MIN, tail pulse, INT ref ASIC settings 2017Oct23-14.38.03 *all* FEE64s slow comparators 0xa *except* nnaida13 0xe, nnaida19-22 0xc Detector biases & leakage currents OK - see attachments 1 & 2 FEE64 Temperatures OK - see attachment 3 DAQ statistics OK - see attachment 4 *all* system wide checks OK *except* nnaida21 fails ADC calibration Julabo FL11006 recirculating chiller set point +20 deg C, actual +20.0 deg C Ambient temperature +23.9 deg C, d.p. +10.8 deg C, RH 43.2% 15.05 per FEE64 Rate, 1.8.L and 1.8.W spectra - note common x & y scales Peak width nnaida5 63 ch FWHM Peak width nnaida8 82 ch FWHM 15.09 All histograms zero'd 18.25 Detector biases & leakage currents OK - see attachments 11 & 12 FEE64 Temperatures OK - see attachment 13 DAQ statistics OK - see attachment 14 *all* system wide checks OK *except* nnaida21 fails ADC calibration