Entry time:
Sat Mar 29 12:36:53 2025
Author
*
:
Subject
*
:
17:59 DAQ continues OK Stats OK - attachment 1 FEE temperatures OK - attachment 2 Bias and leakage currents OK - attachment 3 System-wide checks OK *except* nnaida7 fails ADC calibration 19:07 DAQ continues OK Stats OK - attachment 4 FEE temperatures OK - attachment 5 Bias and leakage currents OK - attachment 6 System-wide checks OK *except* nnaida7 fails ADC calibration 20.19 DAQ starts AIDA file RIBF148/R5_4 BRIKEN file 16 BigRIPS 1001 165Pm setting + 3mm Al degrader 20.21 all online & MIDASsort histograms zero'd 20.23 FEE64 good event statistics - see attachment 7 Merger - see attachment 8 TapeServer - see attachment 9 HEC x versus y spectra - see attachment 10 SN thinks DSSSD #3 are the ions of interest, #4 are the ions of interest at different charge state and #5 & #6 are lighter ions which do not stop in DSSSD #1-6 21.21 DAQ stops DAQ starts AIDA file RIBF148/R5_14 BRIKEN file 18 BigRIPS 1003 21.26 HEC x vs y multiplicity spectra - attachment 11 21.29 HEC Ex vs Ey spectra - attachment 12 FEE64 rate spectra - attachment 13 21.31 1.8.L front/rear energy spectra (attachments 14/15) LEC 21.33 1.8.H front/rear energy spectra (attachments 16/17) HEC 21.46 system wide checks ok, except nnaida7 ADC calibration failure FEE64 good event statistics ok (attachment 18) FEE64 temperatures ok (attachment 19) Leakage currents/detector bias ok (attachment 20) 21.49 Merger and TapeServer ok, no error messages in terminal DAQ still running (RIBF148/R5_18) 22.10 attachment 21 - pulser spectra in all channels fired at same time - FEE64 in sync 22.12 SYNC100 at 9153.8 Hz FEE64 discriminator at ~15000 Hz - higher than expected ~1 second deadtime in FEE19 - due to nnaida12 running fast no timewarps observed in FEE64 all of above in attachment 22 22:32 DAQ continues OK Stats OK - attachment 24 FEE temperatures OK - attachment 23 Bias and leakage currents OK - attachment 25 System-wide checks OK *except* nnaida7 fails ADC calibration 23:30 DAQ continues OK Stats OK - attachment 26 FEE temperatures OK - attachment 27 Bias and leakage currents OK - attachment 28 System-wide checks OK *except* nnaida7 fails ADC calibration
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown