AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
|
AIDA |
 |
|
Message ID: 784
Entry time: Wed Nov 14 14:46:47 2018
|
Author: |
CA |
Subject: |
Thursday 15th November 00:00 - 08:00 |
|
|
23.58 DAQ continues ok (RIBF148/R5_505)
00.09 system wide checks ok, except nnaida7 ADC calibration failure
FEE64 temperatures ok (attachment 1)
good event statistics ok (attachment 2)
detector bias/leakage currents ok (attachment 3)
00.13 Merger and TapeServer run ok (attachment 4/5)
00.26 BRIKEN stop
AIDA file RIBF148/R5_509
00.29 BRIKEN start
AIDA file RIBF148/R5_510
BRIKEN run 70
BigRIPS run 1055
01.46 BRIKEN stop
AIDA file RIBF148/R5_523
01.49 BRIKEN start
AIDA file RIBF148/R5_523
BRIKEN run 71
BigRIPS run 1056
02.05 system wide checks ok, except nnaida7 ADC calibration failure
FEE64 temperatures ok (attachment 6)
good event statistics ok (attachment 7)
detector bias/leakage currents ok (attachment 8)
Merger and TapeServer still ok
02.34 XY hit patterns (attachment 9)
Ex vs Ey plots (attachment 10)
HEC spectra (attachment 11)
LEC spectra (attachment 12)
02.49 BRIKEN stop
AIDA file RIBF148/R5_534
02.50 BRIKEN start
AIDA file RIBF148/R5_534
BRIKEN run 72
BigRIPS run 1057
03.26 zeroed all spectra on online analysis and MIDASsort
04.04 BRIKEN stop
AIDA file RIBF148/R5_546
04.05 BRIKEN start
AIDA file RIBF148/R5_546
BRIKEN run 73
BigRIPS run 1058
04.10 system wide checks ok, except nnaida7 ADC calibration failure
FEE64 temperatures ok (attachment 13)
good event statistics ok (attachment 14)
detector bias/leakage currents ok (attachment 15)
Merger and TapeServer still ok
05.06 BRIKEN stop
AIDA file RIBF/R5_556
05.07 BRIKEN start
AIDA file RIBF148/R5_557
BRIKEN run 74
BigRIPS run 1059
05.08 First 200ms of decay correlations in all detectors
comparison between different Al degrader thickness values (3mm, 2.3mm, 2.8mm)
see attachments 16, 17 and 18 - graphs labelled with detector number and Al degrader thickness
06.09 BRIKEN stop
AIDA file RIBF148/R5_567
06.11 BRIKEN start
AIDA file RIBF148/R5_567
BRIKEN run 75
BigRIPS run 1060
06.16 system wide checks ok, except nnaida7 ADC calibration failure
FEE64 temperatures ok (attachment 19)
good event statistics ok (attachment 20)
detector bias/leakage currents ok (attachment 21)
Merger and TapeServer still ok
06.17 ASIC check load - ok
06.34 XY hit patterns (attachment 22)
Ex vs Ey plots (attachment 23)
HEC spectra (attachment 24)
LEC spectra (attachment 25)
07:12 BRIKEN stop
AIDA file RIBF148/R5_578
07:15 BRIKEN start
AIDA file RIBF148/R5_578
BRIKEN run 76
BigRIPS run 1061
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|