AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
AIDA
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Mar 29 12:26:05 2025
Author
*
:
Subject
*
:
> 15:51 DAQ continues - AIDA file RIBF148/R5_664 > 165Pm BigRIPS setting + 2.8mm Al degrader > > ASIC settings 2018Oct03-13.26.58 > from c. 09.00 13.11.18 > n+n FEE64s Ibias LF feedback 0xb -> 0xd > HEC fast comparator threshold 0x20 -> 0xff > > 15:52 Beam out due to power fault somewhere. > > 15:53 Beam back > BRIKEN and BigRIPS start > BRIKEN file 181115_1553_165Pm_085.dlt > BigRIPS run 1070 > AIDA on run R5_664 > > 16:00 System wide checks all ok *Except nnaida7 fails adc calibration* > Leakage currents and bias ok - attachment 1 > FEE Temps ok - attachment 2 > Statistics ok - attachment 3 > > 16:54 BRIKEN and BigRIPS stop > AIDA on file R5_675 > > 16:55 BRIKEN starts run 181115_1654_165Pm_086.dlt > BigRIPS starts run 1071 > AIDA on file R5_675 > > 17:30 BRIKEBN and BigRIPS stop for BigRIPS team to get access > > 13:46 BRIKEN sends sync pulse resetting timestamp > AIDA on file R5_683 > > 17:49 BRIKEN starts run 181115_1748_165Pm_087.dlt > bigRIPS starts run 1072 > AIDA on file R5_683 > > 18.00 System wide checks ok, except nnaida7 ADC calibration failure > FEE64 Temperatures ok (attachment 4) > Good event statistics ok (attachment 5) > Detector bias/Leakage currents ok (attachment 6) > > 18.04 Merger and TapeServer run ok - no error messages in terminals (attachments 7 and 8) > > 18:48 BigRIPS and BRIKEN stop > AIDA on file R5_693 > > 18:49 BigRIPS starts run 1073 > BRIKEN starts run 181115_1849_165Pm_088.dlt > AIDA on file R5_693 > > 19:47 BgiRIPS and BRIKEN stop > AIDA on file R5_703 > > 19:48 BigRIPS starts run 1074 > BRIKEN starts run 181115_1947_165Pm_089.dlt > AIDA on file R5_703 > > 20:54 bigRIPS and BRIKEN stop > AIDA on file R5_714 > > 20:55 bigRIPS starts run 1075 > BRIKEN starts run 181115_2053_165Pm_090.dlt > AIDA on file R5_714 > > 21:25 System wide checks all ok *Except nnaida 7 fails adc calibration* > Bias and leakage currents ok - attachment 9 > FEE Temps all ok - attachment 10 > Statistics ok - attachment 11 > > 21:55 BRIKEN and BigRIPS stop > AIDA on file R5_724 > > 21:56 BigRIPS starts on run 1076 > BRIKEN starts run > AIDA on file R5_724 > > 22:55 BigRIPS and BRIKEN stop > AIDA on file R5_733 > > 22:56 BRIKEN Starts run > BigRIPS starts run 1077 > AIDA on file R5_733 > > 23.53 Briken stops > AIDA on file R5_743 > > 23.55 BRIKEN starts > bigRIPS run 1078 > BRIKEN starts run 93 > AIDA on file R5_743
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown