Entry time:
Thu May 16 02:13:10 2019
Author
*
:
Subject
*
:
10:13 all system wide checks OK *except* nnaida7 fails ADC calibration FEE64 temperatures OK - see attachment 1 good event statistics OK - see attachments 2 detector biases & leakage currents OK - see attachment 3 Temperature + deg 24.7C dew point +8.6 deg C RH 35.0% Merger and TapeServer ok 10:30 DAQ, merger, TapeServer stop Alpha run stopped at AIDA file TapeData/May19/R2_5 slow comparator threshold lowered to 10 keV (0xa) DAQ start, not writing to file good event statistics after lowering threshold, ok (attachment 4) 10:49 1.8.W spectra 20ms FSR - attachments 5 & 6 11:25 started writing to file R3 (sync test) low threshold run at 5mb/s 11:33 DAQ stop (R3) slow comparator threshold raised to 100 kev (0x64) DAQ start, alpha run Writing to file TapeData/May19/R4 18.49 alpha background ASIC settings 2018Oct03-13.26.58 *except* slow comparator 0xa -> 0x64 BNC PB-4 Pulser OFF FEE64 temperatures OK - see attachment 7 good event statistics - see attachments 8 - nnaida1 405k & nnaida17 368k, all other FEE64s c. 380Hz as expected ASIC check for *all* ASICs & FEE64s restored all FEE64 rates to expected c. 380Hz - see attachment 13 detector biases & leakage currents OK - see attachments 9 & 10 Merger OK - no error messages - see attachment 11 TapeServer OK - see attachment 12 all system wide checks OK *except* nnaida7 fails ADC calibration *and* Check Sync errors not counted Since Baseline - see attachment 14 DAQ stopped May19/R4_3 aidas1> ls -l /TapeData/May19 total 19808048 -rw-rw-rw-. 1 npg npgstaff 1908736000 May 14 18:28 R1_0 -rw-rw-rw-. 1 npg npgstaff 2097152000 May 15 02:30 R2_0 -rw-rw-rw-. 1 npg npgstaff 2097152000 May 15 10:20 R2_1 -rw-rw-rw-. 1 npg npgstaff 2097152000 May 15 18:08 R2_2 -rw-rw-rw-. 1 npg npgstaff 2097152000 May 16 01:57 R2_3 -rw-rw-rw-. 1 npg npgstaff 2097152000 May 16 09:45 R2_4 -rw-rw-rw-. 1 npg npgstaff 190447616 May 16 10:28 R2_5 -rw-rw-rw-. 1 npg npgstaff 1109327872 May 16 11:28 R3_0 -rw-rw-rw-. 1 npg npgstaff 2097152000 May 16 18:39 R4_0 -rw-rw-rw-. 1 npg npgstaff 2097152000 May 16 18:45 R4_1 -rw-rw-rw-. 1 npg npgstaff 2097152000 May 16 18:50 R4_2 -rw-rw-rw-. 1 npg npgstaff 225312768 May 16 18:54 R4_3 -rw-rw-rw-. 1 npg npgstaff 52494336 May 16 19:10 R5_0 Wahtever the issue was it probably occurred before 18.39 DAQ RESET DAQ SETUP ASIC check for *all* ASICs & FEE64s all system wide checks OK *except* nnaida7 fails ADC calibration Sync all ASIC clocks using Re-SYNC DAQ started May19/R5 19.23 1.8.W spectra - see attachments 15 & 16
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Resubmit as new entry
Attachment 1:
190516_1016_temp.png
Original size: 1284x1027
Attachment 2:
190516_1017_stats.png
Original size: 1284x1027
Attachment 3:
190516_1018_bias.png
Original size: 1004x347
Attachment 4:
190516_10.png
Original size: 1284x1027
Attachment 5:
190516_1046_18wfront.png
Original size: 1284x1027
Attachment 6:
190516_1048_18wback.png
Original size: 1284x1027
Attachment 7:
1.png
Original size: 1284x1027
Attachment 8:
2.png
Original size: 1284x1027
Attachment 9:
3.png
Original size: 502x344
Attachment 10:
4.png
Original size: 502x344
Attachment 11:
5.png
Original size: 1257x1027
Attachment 12:
6.png
Original size: 1257x1027
Attachment 13:
7.png
Original size: 1284x1027
Attachment 14:
8.png
Original size: 1284x1027
Attachment 15:
11.png
Original size: 1284x1027
Attachment 16:
12.png
Original size: 1284x1027
Attachment 17:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown