> 11.43 DAQ continues OK > > ASIC settings 2019May19-17.54.03 > slow comparator 0xa > > BNC PB-4 Pulser > Amplitude 90,000 > x5 attenuator IN > Frequency 25Hz range, variable min. c. 2.5Hz > t_r 100ns, tau_d 50us > - polarity > Delay MIN, tail pulse > > all system wide checks OK *except* nnaida7 fails ADC calibration > > detector biases & leakage currents OK - see attachments 1 & 2 > > FEE64 temperatures OK - see attachment 3 > > good event statistics - DSSSD#1 noisy - see attachments 4 > 10x <20k, 19x <50k, 20x <100k cf. 13x <20k 22x < 50k 24x <100k yesterday afternoon > Merger OK - see attachment 5 > TapeServer OK - see attachment 6 > > p+n FEE64s 1.8.W spectra 20us FSR - DSSSD#1 noisy - attachment 7 > n+n FEE64s 1.8.W spectra 20us FSR - DSSSD#1 noisy - attachment 8 > 1.8.L spectra - see attachments 9 & 10 > nnaida1 76 ch FWHM, nnaida3 83 ch FWHM - cf. 104 & 111 ch FWHM respectively yesterday aftenoon > > FEE64 Rate spectra - attachment 11 > Check ASIC Control *all* FEE64s & ASICs x2 > FEE64 Rate spectra - attachment 12 > > 11.46 ADC data synchronised - attachment 13 > > p+n FEE64s 1.8.W spectra 20us, 200us, 2ms & 20ms FSR - DSSSD#1 noisy - attachments 14-17 > > Check ASIC Control *all* FEE64s & ASICs x2 - no change DSSSD#1 noise > > DSSSD#1 bias cycle - no change DSSSD#1 noise > > press Kapton Samtec into adaptor PCBs - reduces DSSSD#1 noise to previous levels > > 12.17 Julabo FL11006 chiller set point +20 deg C actual +20.0 deg C > Water level c. 60% M-H markers > Temperature +25.3 deg C dew point +7.6 deg C RH 32.2% > > 12.23 temporary fix for DSSSD#1 noise? check by > zero all histograms > zero DAQ stats > > ...and wait > > good event statistics - DSSSD#1 noisy - see attachments 18 > 11x <20k, 21x <50k, 23x <100k > > 13.30 DAQ stop > > OH replaces LH kapton PCB for DSSSD#1 n+n FEE64s 20 & 23 which we suspect may be damaged due to twist > placed on kpaton cables by weight of all ribbon cables + cu foil shielding - particularly pronounced > for nnaida20 > > good event statistics - OK - see attachments 19 > 7x <20k, 20x <50k, 24x <100k > p+n FEE64s 1.8.W spectra 20us FSR - OK - attachment 20 > > good event statistics - OK - see attachment 21 > 7x <20k, 22x <50k, 24x <100k > p+n FEE64s 1.8.W spectra 20us FSR - OK - attachment 22 > > 17.50 detector biases & leakage currents OK - see attachments 23 & 24 > > FEE64 temperatures OK - see attachment 25 > > good event statistics - OK - see attachments 26 > 9x <20k, 21x < 50k, 24x <100k cf. 10x <20k, 19x <50k, 20x <100k earlier today > > p+n FEE64s 1.8.W spectra 20us FSR - DSSSD#1 noisy - attachment 7 > n+n FEE64s 1.8.W spectra 20us FSR - DSSSD#1 noisy - attachment 8 > > 17.57 all histograms zero'd > DAQ stats zero'd
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown