AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
AIDA
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Mar 29 11:35:37 2025
Author
*
:
Subject
*
:
It's a new day, it's a new log entry !! 01:25 DTAS run 46 started BigRIPS run 2019 AIDA run R2_268 DAQ running smoothly No change in Stat and Rate (stat zeroed at the beginning of this DTAS run)- See attachment 1 Merger rate: 630k item/sec - See Attachment 2 TapeServer rate still ~5 Mbytes/sec - See attachment 3 Temperature and HV ok - See attachment 5 & 6 System-wide checks OK except nnaida7 fails ADC calibration as usual. !!! Victor said that the run AIDA R2_249 is missing in the correlation merge data. This is the run when the correlation scaler was reset (as DTAS was running out of range in some of their timing histograms) (See elog end of Sunday) !!! 02:23 Rate in DSSD#3 card 9 and 12 slowly reaching 100kHz while 14 and 15 ~ 50kHz. See attachment 7 TapeServer rate ~ 5.5 kHz 03:25 Change of DTAS run: DTAS run 49 started BigRIPS run 2020 AIDA run R2_286 Experiment still running smoothly. No significant change since last comments 2h ago. Leakage current in detector 3 is increasing slowly see attachment 8 & 9 05:25 Change of DTAS run: Note: DTAS run stopped during AIDA R2_305 and re-started during R2_306. DTAS run 52 started BigRIPS run 2021 AIDA run R2_306 Pretty quiet night shift. Stat & Rate in attachment 10 - DSSD#3 FEE card 9 back down to 60kHz Merger rate: 650k item/sec - See attachment 11 TapeServer rate still ~5.1 Mbytes/sec - See attachment 12 System-wide checks OK except nnaida7 fails ADC calibration as usual. X vs Y HEC spectrum in attachment 13 LEC E vs HEC-LEC spectrum in attachment 14 Both spectra zeroed Bias in attachment 15 Temperature unchanged 07:30 DTAS and BigRIPS stop runs AIDA on file R2_323 07:33 New Run numbers DTAS Run: 55 BigRIPS Run: 2022 AIDA on File: R2_324 07:56 System wide checks ok Fee temps ok - attachment 16 100Sn setting, no degrader ASIC settings 2019Jun13-08.56.35 BNC PB-4 Pulser Amplitude 90,000 x5 attenuator IN Frequency 25Hz range, variable min. c. 2.5Hz t_r 100ns, tau_d 50us - polarity Delay MIN, tail pulse 08:28 Bias and leakage ok - attachment 17 08:48 ASIC check successful 09:32 DTAS and BigRIPS stop AIDA on file R2_342 DTAS starts file 58 BigRIPS run 2023 AIDA still on file R2_342
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown