AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
AIDA
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Mar 29 12:37:30 2025
Author
*
:
Subject
*
:
00:00 New day. The DAQ continues OK Beam setting 2 for enhanced yield of Sn100 No degrader Statistics OK - see attach 1 FEE64 temps OK - see attach 2 Merger & Tape server OK - see attach 3 & 4 Bias OK - see attach 5 All system-wide checks OK, except nnaida7 fails ADC calibration 00:19 AIDA R2_473 DTAS 82 BigRIPS 2036 01:50 FEE temps and bias/leakage currents OK Data rate continues at ~620k items/s and ~5.1MB/s ASIC check performed successfully 02:29 DTAS run 85 BigRIPS run 2037 AIDA ~1.5GB into R2_492 02:30 DTAS reset correlation scaler at start of R2_493 Confirmed by change in value in Correlation status & control @ aidas1 window. 02:36 DTAS run 86 started BigRIPS run 2038 AIDA file R2_494 04:38 DTAS run 88 stopped. AIDA run R2_512. DTAS run 89 started. BigRIPS run 2039 AIDA run R2_512 (1.8GB) Temps + bias/leakage currents still ok Data rate still ~600k items/s and ~5MB/s Individual Good data rates remain roughly constant (see attachment 6) All system-wide checks passed, except nnaida7 fails ADC calibration 05:48 Stats and histograms zeroed 06:28 DTAS run 91 stopped. AIDA run R2_528 at the time. DTAS run 92 started BigRIPS run 2040 AIDA run R2_528 07:50 Made some basic observations with the first file merged after the setting change Attachment 7 shows implant x:y plots for each DSSD Attachment 8 show PID for second setting with 100Sn highlighted in red and 96Ag in magenta 08:21 PID per DSSD Attachment 9 Sn100 per DSSD attachment 10 Sn100 Velocity against DSSD 11 Sn100 Velocity against DSSD Energy attachment 12 08:29 DTAS and BigRIPS stop AIDA on file R2_546 DTAS starts file 95 BigRIPS run 2041 AIDA on file R2_547 08:53 Stats ok - attachment 13 Temps ok - attachment 14 System wide checks ok ASIC check ok Bias and leakage still ok though DSSD3 continues to rise - attachment 15 Merger continues with data rate around 700k - attachment 16 09:43 With the new implantation profile depositing most of the Sn100 in DSSD2 but some in the 3rd the plan is to put in place a 200 micron degrader to bring the deposition into the centre of detector 2 10:15 Overnight MIDAS analysis has been completed. Spectra have been exported to: /homes/npg/spectra/specs-2019Jun18-10.14.36 MIDAS will be switched to online mode with the change in degrader setting 10.33 DAQ stop AIDA file RIBF147/R2_566 OH/AA/SN add 0.3mm Al degrader to Pb wall immediately upstream of the (CH2)n shield 10.35 Julabo FL11006 chiller set point +20 deg C actual +20.0 deg C Water level c. 50% M-H markers Temperature +24.1 deg C dew point +9.7 deg C RH 39.8% 10.39 DTAS starts file 98 BigRIPS run 2042 AIDA on file R2_567 11:06 Implantation events for the 2nd setting with 0,3mm Al plate - attachments 17-19 FEE64 Rate spectra - attachment 20 FEE64 HitRate spectra - attachment 21 1.8.L spectra - see attachments 22-25 nnaida1 73 ch FWHM, nnaida3 77 ch FWHM - cf. 73 & 78 ch FWHM respectively 10.41 yesterday 1.8.H spectra - see attcahments 26-27 p+n FEE64s 1.8.W spectra 20us FSR - attachment 28 n+n FEE64s 1.8.W spectra 20us FSR - attachment 29 11.30 Check ASIC Control *all* FEE64s & ASICs zero *all* histograms zero DAQ stats 11.50 analysis of RIBF147/R2_576 deadtime *all* FEE64s <<1% no timewarps 11.57 ADC data synchronised - attachment 30 per FEE64 ADC data / 20.48us - attachment 31 12:39 DTAS and BigRIPS stop runs AIDA on file R2_585 DTAS file 101 BigRIPS run 2043 AIDA on File R2_585 13:23 System wide checks ok 14:38 DTAS and BigRIPS stop runs AIDA on file R2_683 OH offline analysis of BigRIPS-implant correlations for previous 2h indicates >90% of 100Sn are now in DSSSD#2 with small d=fraction remaining in DSSSD#3 100Sn setting, 0.3mm Al degrader ASIC settings 2019Jun13-08.56.35 DSSSD#1 slow comparator 0xa -> 0x1d DSSSD#2 slow comparator 0xa -> 0x8 DSSSD#3 slow comparator 0x8 -> 0xa DAQ stats before & after chn age of slow comparator thresholds above - see attachments 33 & 34 before 11x <20k 21x <50k 24x <100k cf after 11x <20k 22x <50k 23x <100k merger 664k items/s cf 560k data items/s BNC PB-4 Pulser Amplitude 90,000 x5 attenuator IN Frequency 25Hz range, variable min. c. 2.5Hz t_r 100ns, tau_d 50us - polarity Delay MIN, tail pulse 15.03 DAQ start AIDA file R2_606 DTAS file 104 BigRIPS run 2044
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown