Entry time:
Sat Mar 29 11:18:06 2025
Author
*
:
Subject
*
:
> 00.00 Shift Change > > DAQ continues ok > > AIDA file RIBF147/R2_697 > DTAS run 118 > BigRips run 2048 > > BNC PB-4 Pulser > Amplitude 90,000 > x5 attenuator IN > Frequency 25Hz range, variable min. c. 2.5Hz > t_r 100ns, tau_d 50us > - polarity > Delay MIN, tail pulse > > 0.3mm Al degrader > > 00.15 System wide checks all ok *except* naida7 fails ADC calibration > > 00.19 FEE64 temperatures ok - attachment 1 > > good event statistics ok - attachment 2 > > detector bias/leakage currents ok - attachment 3 > > tape service ok - attachment 4 > > merger ok - attachment 5 > > 01.19 DTAS stop/start (verified with DTAS2019 ELOG) > > DTAS Stop: 01:19 > DTAS run: 121 > AIDA run: 708 > BigRIPS run: 2049 > > DTAS Start: 01:19 > DTAS run: 122 > AIDA run: 708 > BigRIPS run: 2049 > > 01.46 Primary beam at 120 pnA; implants around 250 cps at F11 > > 01.48 High Energy Spectra (1.8.H) for front and back strips, respectively (attachments 6 & 7) > > 02.35 HEC XY hit pattern - implants mostly in DSSD2 - attachment 8 > HEC multiplicity n vs p - attachment 9 > HEC Ey vs Ex - attachment 10 > Implant - decay time vs Energy - attachment 11 > > 02.46 zeroed all histograms, online sort stats zeroed > > 02.49 HEC XY hit pattern - ~3 minutes after zeroing - attachment 12 > > 02.52 Primary beam at 120 pnA; implants around 250 cps at F11 > > 03.20 analyser output file R2_726 - attachment 13 > no timewarps > ~1s deadtime on nnaida19 > ~0.8s deadtime on nnaida24 > 0s for rest > > 03.23 DTAS stop run 125 > AIDA file R2_728 > BigRIPS run 2049 > > DTAS start run 126 > AIDA file R2_728 > BigRIPS run 2050 > > 03.28 Check ASIC control > > 04.16 HEC XY hit pattern - less implants than expected - attachment 14 > > HEC XY hit pattern - change refresh rate to 10s.... looks ok. Sorry Tom! - attachment 15 > > 04.26 FEE64 temperatures ok - attachment 16 > > 04.28 System wide checks all ok *except* naida7 fails ADC calibration > > good event statistics ok - attachment 17 > > detector bias/leakage currents ok - attachment 18 > > merger & TapeServer ok - attachments 19 & 20 > > 05.32 Primary beam at 120 pnA; implants around 250 cps at F11 > > 05.36 DTAS stop run 129 > AIDA file R2_749 > BigRIPS run 2050 > > 05.40 DTAS send sync pulse AIDA file R2_750 > > 05.43 DTAS start run 130 > AIDA file R2_751 > BigRIPS run 2051 > > 06.31 HEC XY hit pattern - implants mostly in DSSD2 - attachment 21 > HEC multiplicity n vs p - attachment 22 > HEC Ey vs Ex - attachment 23 > Implant - decay time vs Energy - attachment 24 > > 06.34 High Energy Spectra (1.8.H) for front and back strips, respectively (attachments 25 & 26) > > 06.36 3.20 analyser output file R2_731 - attachment 27 > no timewarps > ~1.7s deadtime on nnaida19 > ~0.8s deadtime on nnaida24 > 0s for rest > > 07.19 System wide checks all ok *except* naida7 fails ADC calibration > > good event statistics ok - attachment 28 > > FEE64 temperatures ok - attachment 29 > > detector bias/leakage currents ok - attachment 30 > > 07.21 Merger & TapeServer ok - attachments 31 & 32 > > 07.30 DTAS stop run 132 > AIDA file R2_768 > BigRIPS run 2051 > > DTAS start run 133 > AIDA file R2_768 > BigRIPS run 2052 > > > > > > > > > > > > > > > > > > > > > > > > >
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown