AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
AIDA
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Tue Jun 18 23:58:46 2019
Author
*
:
Subject
*
:
08:00 Shift change No change in settings DAQ continues running OK Good events rate OK - see attach 1 FEE64 temperature OK - see attach 2 Merger & Tape server OK - see 3 & 4 Leakage currents OK - see attach 5 Online HEC xy plot OK, most implants in DSSD2 - see attach 6 Zeroed online histograms 09:29 DTAS DAQ stops on run 135 AIDA on run R2_787 09:32 DTAS DAQ restarts on run 136 AIDA on run R2_787 BigRIPS on run 2053 09:33 DAQ continues OK Good events rate OK - see attach 7 Merger ~ 700k items/s Tape ~ 5400 Kbytes/s Leakage currents OK - see attach 8 Online HEC xy plot OK - see attach 9 10:31 Good event rate in nnaida 19, 24 steadily creeping up. See attach 10. Currently 160k and 120k Merger ~ 710 k items/s Tape ~ 5689 kbytes/s All system-wide checks OK, except nnaida7 fails ADC calibration as usual 11:20 Good event rate stable - see attach 11 FEE64 temperatures OK - see attach 12 Merger ~700k items/s Tape server ~ 5500 Kbytes/s Leakage currents OK - see attach 13 & 14 11:30 DTAS stops DAQ on run 139 BigRIPS on run 2053 AIDA on run R2_806 11:32 DTAS restarts on run 140 BigRIPS 2053 AIDA R2_807 13:14 DAQ continues OK Good statistics events stable - see attach 15 Merger ~ 730k items/s Tape server ~ 5500 KBytes/s Leakage current OK - see attach 16 13:34 DTAS stops DAQ on AIDA R2_826 13:37 DTAS restarts DAQ on run 144 BigRIPS run 2055 AIDA run 827 15:10 DTAS DAQ reports 20% drop in F11 counting rate AIDA plastic unchanged, beam current unchanged. Focusing issue? Reset online histograms to check we are still implanting. We are. Acquisition continues uninterrupted. 15:17 Good statistics OK - see attach 17 FEE64 temperature OK - see attach 18 Merger ~ 700k items/s TapeServer ~ 5500 Kbytes/s Detector leakage current OK - see attach 19 15:30 DTAS stops DAQ on AIDA run R2_845 15:33 DTAS restarts DAQ on run 147 BigRIPS run 2056 AIDA run R2_846
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Resubmit as new entry
Attachment 1:
190619_0801_temps.png
Original size: 1284x1030
Attachment 2:
190619_0802_bias.png
Original size: 1004x346
Attachment 3:
190619_8000_stats
Attachment 4:
190619_8001_merger.png
Original size: 1281x1027
Attachment 5:
190619_8002_tape.png
Original size: 1281x1027
Attachment 6:
190619_8003_HEC.png
Original size: 1049x470
Attachment 7:
190619_0933_stats.png
Original size: 1284x1030
Attachment 8:
190619_0935_bias.png
Original size: 1005x344
Attachment 9:
190619_0935_HEC.png
Original size: 1048x466
Attachment 10:
190619_1032_stats.png
Original size: 1284x1030
Attachment 11:
190619_1120_stats.png
Original size: 1284x1030
Attachment 12:
190619_1120_temps.png
Original size: 1284x1030
Attachment 13:
190619_1122_bias.png
Original size: 1004x348
Attachment 14:
190619_1123_leakage.png
Original size: 974x358
Attachment 15:
190619_1314_stats.png
Original size: 1284x1030
Attachment 16:
190619_1315_bias.png
Original size: 1001x345
Attachment 17:
190619_1518_stats.png
Original size: 1284x1030
Attachment 18:
190619_1518_temps.png
Original size: 1284x1030
Attachment 19:
190619_1519_bias.png
Original size: 1004x351
Attachment 20:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown