Subject
*
:
> Silena 7710 - see attachment 1 > > Bias -60V > > > Without ac mains filter - attachments 2-6 > > DSO ch#1 AC/1M - y: 10mV/div x: 100ns, 200ns, 1us, 2us & 10us/div > > > > With ac mains filter - attachments 7-11 > ( see https://elog.ph.ed.ac.uk/nToF/67 attachments 2 & 3 ) > > DSO ch#1 AC/1M - y: 10mV/div x: 100ns, 200ns, 1us, 2us & 10us/div > > > Conclusion - Claud Lyons Ltd STF Series Surge & Transient Power Filter makes little observable difference to HF noise transients observed