> Some first analysis of building events to look for implants and decays > > Using both DISC and slow comparator values for time-stamp (whatever is available). Clearly there are some ADC > hits with a very early value for their corresponding time-stamp, that result in negative or very large dTS > values. Probably safer to use only ADC data for now (it's likely the simple algorithm used to correlate > discriminator hits and ADC hits can not cope with current conditions of ADC hits >> DISC hits): > > time_stamp_dist_disc.png > > Comparing analysis of file R51_3 for the two conditions: using the Fast discriminator data when available for > low energy range, or using only the time-stamp from the ADC hits. > > > The first two figures (time_stamp_dist_disc.png, XY_implant_disc_R51.png) are for including DISC hits as > time-stamp for event building: some have much smaller values than corresponding ADC hits, so the event is cut > short and we see a small number of identified implants. > > Second set of plots is the same data but using only the timestamp for the slow comparator of the low energy > range. The number of identified events is much higher (compare 'Integral' value of the stats box).