Fri Jun 9 16:22:54 2017, PV, Saturday 10 June 00:00-08:00 28x
|
00:21 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_826
00:23 BRIKEN starts run 101
BigRIPS starts run 3107
AIDA on file R7_827
00:26 Offline Analysis of file RIBF128/R7_826- zero timewarps, zero MBS timewarps - see attachment 1
High Energy hit pattern spectra - see attachment 2
AIDA on file R7_828
zeroed Midas sort online spectra
00:36 *All* system wide checks OK
FEE64 Temperatures OK - see attachment 3
Good events statistics OK - see attachment 4
Merger and tape server running - see attachment 5, 6
Detector biases and leakage currents OK - see attachment 7
01:22 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_841
01:24 BRIKEN starts run 102
BigRIPS starts run 3108
AIDA on file R7_841
02:22 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_855
02:23 BRIKEN starts run 103
BigRIPS starts run 3109
AIDA on file R7_856
02:25 Offline Analysis of file RIBF128/R7_855- zero timewarps, 2 MBS timewarps - see attachment 8
High Energy hit pattern spectra - see attachment 9
AIDA on file R7_856
zeroed Midas sort online spectra
02:30 *All* system wide checks OK
FEE64 Temperatures OK - see attachment 10
Good events statistics OK - see attachment 11
Merger and tape server running - see attachment 12, 13
Detector biases and leakage currents OK - see attachment 14
03:24 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_870
03:26 BRIKEN starts run 104
BigRIPS starts run 3110
AIDA on file R7_871
03:42 fRC RF is down, beam is off
03:46 beam is back
04:18 beam is off, fRC RF is down
04:21 beam is back
04:31 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_886
04:32 BRIKEN starts run 105
BigRIPS starts run 3111
AIDA on file R7_887
04:35 Offline Analysis of file RIBF128/R7_886- zero timewarps, 1 MBS timewarps - see attachment 15
High Energy hit pattern spectra - see attachment 16
AIDA on file R7_887
zeroed Midas sort online spectra
04:39 *All* system wide checks OK
FEE64 Temperatures OK - see attachment 17
Good events statistics OK - see attachment 18
Merger and tape server running - see attachment 19, 20
Detector biases and leakage currents OK - see attachment 21
05:31 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_901
05:32 BRIKEN starts run 106
BigRIPS starts run 3112
AIDA on file R7_901
06:30 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_916
06:31 BRIKEN starts run 107
BigRIPS starts run 3113
AIDA on file R7_916
06:35 Offline Analysis of file RIBF128/R7_915- zero timewarps, 2 MBS timewarps - see attachment 22
High Energy hit pattern spectra - see attachment 23
AIDA on file R7_917
zeroed Midas sort online spectra
06:37 *All* system wide checks OK
FEE64 Temperatures OK - see attachment 24
Good events statistics OK - see attachment 25
Merger and tape server running - see attachment 26,27
Detector biases and leakage currents OK - see attachment 28
06:46 RRC power is down, it may take more than 1 hour to fix the problem
AIDA on file R7_920
06:48 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_920
06:52 BRIKEN starts run 108 (background run without beam)
AIDA on file R7_921 |
Fri Jun 9 09:12:03 2017, ZLiu, AE, 17:00-24:00    
|
17:06 BRIKEN and BigRIPS stop their DAQs
AIDA on file R7_723
17:08 BigRIPS starts run 3100
BRIKEN starts run 94
AIDA on file R7_724
18:11 Stop BRIKEN/BigRIPS run. AIDA at R7_739
18:13 Start new run: BRIKEN 95, BigRIPS run 3103
AIDA run R7_740
Beam stopped right when the run was started.
18:17 Beam back, with intensity about 49 pnA
18:43 AIDA leakage currents [uA]: 4.665 5.325 5.705 5.125 5.05 4.25
19:09 BRIKEN starts run 096
BigRIPS starts run 3102
AIDA on file R7_753
20:11 Beam stop due to SRC issue. BRIKEN/BigRIPS runs stopped
20:17 Beam is back (49 pnA)
BRIKEN starts run 097
BigRIPS starts run 3103
AIDA on file R7_769
21:00 There have been frequent interruptions of beam (FRC/SRC issues) during the last two to three hours.
Usually resolved after a few minutes, with the beam continuing with good current.
21:12 BRIKEN starts run 098
BigRIPS starts run 3104
AIDA on file R7_782
Screenshot for stats and temperature during R7_783 attached (att. 2 and 3)
Screenshot for energy spectra of FEE12 and 9 as attachment 4 and 5 (around run R7_785)
21:58 BRIKEN starts run 099
BigRIPS starts run 3105
AIDA on file R7_793
23:12 BRIKEN starts run 100
BigRIPS starts run 3106
AIDA on file R7_810 |
Fri Jun 9 04:53:24 2017, TD, Waveforms 28x
|
x-scale 1000ch = 2ms
y-scale expanded
p+n junction strips
DSSSD #1 .. #6 attachments 1-12
n+n ohmic strips
DSSSD #1 .. #6 attachments 13-24
DSSSD #4 pulser off, attachments 25-28 |
Thu Jun 8 23:57:26 2017, ZLiu, TD, 9June2017 8:00-16:00 32x
|
08:06 System wide checks all ok
implantation profile - attachment 1
count rate - attachment 2
Bias and leakage currents ok - attachment 3
DAQstatistics
08:30 BRIKEN and BigRIPS stop their DAQs
AIDA on file R7_604
08:32 BigRIPS starts run 3090
BRIKEN starts run 85
AIDA on file R7_604
08:44 BRIKEN and BigRIPS stop their DAQs
AIDA on file R7_607
08:49 BigRIPS starts run 3091
BRIKEN starts run 86
AIDA on file R7_608
09:42 BRIKEN and BigRIPS stop their DAQs
AIDA on file R7_621
*** DAQ synchronisation reset ***
see BRIKEN 2017 Elog http://ribf-exp.riken.jp/elog/BRIKEN2017-June/323
09:51 BigRIPS starts run 3093
BRIKEN starts run 87
AIDA on file R7_623
10:06 System wide checks all ok
Bias and leakage currents ok - attachment 5
count rate - attachment 6
implantation profile - attachment 7
FEE temperature - attachment 8
10.30 layout spectra - see attachments 9-18
analysis of RIBF128/R7_630 - deadtime < 0.5%, no ts timewarps, 4x MBS timewarps - see attachment 19
online analysis - ADC & disc data synchronsed - see attachment 20
10.36 all histograms and SortSas spectra zero'd
10:53 BRIKEN and BigRIPS stop their DAQs
AIDA on file R7_636
10:54
BigRIPS starts run 3094
BRIKEN starts run 88
AIDA on file R7_636
11:49 BigRIPS and BRIKEN stop their DAQ
AIDA on file R7_649
11:49 BigRIPS starts run 3095
BRIKEN starts run 89
AIDA on file R7_649
12:15 system wide checks -- OK
see attchments 21-26
12.54 DAQ stop
AIDA file RIBF128/R7_664
12.55 DAQ start
AIDA file RIBF128/R7_664
BRIKEN file 3096
BigRIPS file 90
13.55 BigRIPS team entered the beam line area to place a 1.5 mm Al degrader
DAQ stop
AIDA file on RIBF128/R7_679
BRIKEN file 3096
BigRIPS file 90
14:03 BigRIPS starts run 3097
BRIKEN starts run 91
AIDA on file R7_680
14:52 beam stopped
15:00 BRIKEN and BigRIPS stop their DAQs
AIDA on file R7_694
15:02
BigRIPS starts run 3098
BRIKEN starts run 92
AIDA on file R7_694
15:48 beam stopped
15:52 beam back
16:06 BRIKEN and BigRIPS stop their DAQs
AIDA on file R7_709
16:08
BigRIPS starts run 3099
BRIKEN starts run 93
AIDA on file R7_710
16:20 system wide checks--OK
see attachments 27-32
17:06 BRIKEN and BigRIPS stop their DAQs
AIDA on file R7_723
17:08
BigRIPS starts run 3100
BRIKEN starts run 94
AIDA on file R7_724 |
Thu Jun 8 16:06:21 2017, OH, Friday 9 June 00:00-08:00 9x
|
00:06 System wide checks all ok
Bias and leakage currents ok - attachment 1
Good event statistics - attachment 2
FEE temperatures - attachment 3
00:29 BRIKEN and BigRIPS stop their DAQs
AIDA on file R7_494
00:31 BigRIPS starts run 3080
BRIKEN starts run 77
AIDA on file R7_494
01:31 BigRIPS and BRIKEN stop DAQs
AIDA on file R7_508
01:33 BRIKEN starts run 78
BigRIPS starts run 3081
AIDA on file R7_508
02:10 System wide checks all ok
Bias and leakage ok - attachment 4
Good event statistics - attachment 5
FEE temperatures - attachment 6
02:30 BRIKEN and BigRIPS stop their DAQs
AIDA on file R7_211
02:32 BigRIPs started Run 3082
BigRIPS stopped
02:33 Beam stopped to put and extra 1mm of degrader in to shift beam
Current degrader settings:
F7 = 2mm Al
F11 = 4.5mm Al
02:39 biGRIPS starts run 3083
BRIKEN starts run 79
AIDA on file R7_523
DSSD rates from R7_235
*** DSSSD # 1 count: 119355 old count: 78874 dt: 1.05 s LEC rate: 38696.78 Hz
*** DSSSD # 2 count: 188044 old count: 124828 dt: 1.05 s LEC rate: 60429.72 Hz
*** DSSSD # 3 count: 53151 old count: 34736 dt: 1.05 s LEC rate: 17603.35 Hz
*** DSSSD # 4 count: 61647 old count: 40919 dt: 1.05 s LEC rate: 19814.40 Hz
*** DSSSD # 5 count: 14623 old count: 9739 dt: 1.05 s LEC rate: 4668.74 Hz
*** DSSSD # 6 count: 41905 old count: 27687 dt: 1.05 s LEC rate: 13591.33 Hz
*** DSSSD # 1 count: 1 old count: 1 dt: 1.05 s HEC rate: 0.00 Hz
*** DSSSD # 2 count: 11 old count: 7 dt: 1.05 s HEC rate: 3.82 Hz
*** DSSSD # 3 count: 19 old count: 10 dt: 1.05 s HEC rate: 8.60 Hz
*** DSSSD # 4 count: 15 old count: 10 dt: 1.05 s HEC rate: 4.78 Hz
*** DSSSD # 5 count: 0 old count: 0 dt: 1.05 s HEC rate: 0.00 Hz
*** DSSSD # 6 count: 3 old count: 2 dt: 1.05 s HEC rate: 0.96 Hz
03:37 bigRIPS and BRIKEN stop their daqs
AIDA on file R7_537
03:39 BigRIPS starts run 3084
BRIKEN starts run 80
AIDA on file R7_537
04:16 System wide checks ok
Leakage and bias ok - attachment 7
Good events - attachment 8
FEE temperatures - attachment 9
04:33 BRIKEN AND BigRIPS stop daqs
AIDA on file R7_549
04:34 BRIKEN starts run 81
BigRIPS starts run 3085
AIDA on file R7_550
05:30 BigRIPS and BRIKEN stop their DAQs
AIDA on file R7_563
05:40 bigRIPS starts run 3086
BRIKEN starts run 82
AIDA on R7_565
06:14 System wide checks all ok
Bias and leakages ok - attachment 10
Good events - attachment 11
FEE temperatures - attachment 12
06:33 BigRIPS and BRIKEN stop their DAQs
AIDA on file R7_577
06:34 BigRIPS starts run 3087
BRIKEN starts run 83
AIDA on file R7_577
07:30 BRIKEN and BigRIPS stop daqs
AIDA on file R7_590
07:31 BigRIPS starts run 3088
BRIKEN starts run 84
AIDA on file R7_591 |
Thu Jun 8 08:11:39 2017, NN, PV, Thursday 8 June 16:00 - 24:00 (evening shift) 22x
|
16:13 DAQ still running
16:34 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_388
16:36 BRIKEN starts run 069
BigRIPS starts run 3072
AIDA on file R7_389
16:37 Analysis of file RIBF128/R7_387 - zero timewarps, four MBS timewarps - see attachment 1
16:41 Beam is OFF
16:43 Beam is ON
17:04 *All* system wide checks OK
FEE64 Temperatures OK - see attachment 2
Good events statistics OK - see attachment 3
Merger and tape server running - see attachment 4,5
17:06 Detector biases & leakage currents OK - see attachment 6
17:37 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_402
17:40 BRIKEN starts run 070
BigRIPS starts run 3073
AIDA on file R7_403
18:32 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_415
18:34 BRIKEN starts run 071
BigRIPS starts run 3074
AIDA on file R7_416
18:36 Offline Analysis of file RIBF128/R7_412 - zero timewarps, zero mbs timewarps - see attachment 7
18:58 *All* system wide checks OK
FEE64 Temperatures OK - see attachment 8
Good events statistics OK - see attachment 9
Merger and tape server running - see attachment 10,11
Detector biases and leakage currents OK - see attachment 12
19:34 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_428
19:35 BRIKEN starts run 072
BigRIPS starts run 3075
AIDA on file R7_429
20:08 Offline Analysis of file RIBF128/R7_434 - zero timewarps, one mbs timewarps - see attachment 13
20:10 High Energy Correlation spectra - see attachment 14
AIDA on file R7_436
20:37 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_442
20:37 BRIKEN starts run 073
BigRIPS starts run 3076
AIDA on file R7_443
21:37 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_455
21:38 BRIKEN starts run 074
BigRIPS starts run 3077
AIDA on file R7_455
22:00 *All* system wide checks OK
FEE64 Temperatures OK - see attachment 15
Good events statistics OK - see attachment 16
Merger and tape server running - see attachment 17,18
Detector biases and leakage currents OK - see attachment 19
22:10 Offline Analysis of file RIBF128/R7_434 - zero timewarps, one mbs timewarps of FEE No.6 - see attachment 20
22:26 High energy hit pattern - see attachment 21
AIDA on file 466
Zero'd online spectra
22:39 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_469
22:40 BRIKEN starts run 075
BigRIPS starts run 3078
AIDA on file R7_470
23:42 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_483
23:43 BRIKEN starts run 076
BigRIPS starts run 3079
AIDA on file R7_484
23:47 Offline Analysis of file RIBF128/R7_480 - zero timewarps, one mbs timewarps - see attachment 22 |
Thu Jun 8 00:54:26 2017, OH, PW, Thursday 8 June 00:00-16-00 6x
|
08:54 DAQ still running
09:01 BRIKEN and BigRIPS stop daqs
AIDA on file R7_293
Beam stopped
09:25 System wide checks ok
Bias and leakage ok - attachment 1
Good event statistics - attachment 2
FEE temperatures - attachment 3
13:36 Beam about to be back
Briken on Run 65 (Background)
AIDA on file 350
13:37 Beam is returned
BRIKEN starts run 66
bigRIPS run 3069
AIDA on file R7_350
System wide checks ok
13:40 Bias and leakage ok - attachment 4
Good event - attachment 5
FEE temperatures - attachment 6
14:00 Beam down originally five minutes
14:08 Beam will be down for another 20 minutes
BRIKEN and BigRIPS stop daqs
AIDA on file R7_356
14:22 beam is back
14:23 BigRIPS starts run 3070
Briken starts run 67
AIDA on file R7_360
15.23 DAQ stop
AIDA file RIBF128/R7_373
15:26 BigRIPS starts run 3071
Briken starts run 68
AIDA on file R7_374
15.29 beam off - back in 5 mins
AIDA file RIBF128/R7_374
15.44 beam back
AIDA file RIBF128/R7_377
|
Wed Jun 7 16:04:42 2017, ZL, DK, Thurs 8 June 0:00~8:00 13x
|
00:05 Shift change.
Primary beam current ~4800 enA, 238U^86+ so 50 to 60 pnA.
Biases shown as attachment #1, 08JunBias1.png
Analysis of R7_176 as attachment #2, 08 JunStats1.txt
3 MBS timewarps seen, no global timewarps
Implant rate is low, maybe 5 to 10 cps at AIDA
All system-wide checks are passed.
Sync pulses about 50% of last night, 18 x 10^6 because of run restart at 10:00
FEE64 memory consistent, about 36k ~ 39k
00:35 AIDA at R7_183 when runs stopped.
00:36 AIDA still R7_183 when runs starts: BRIKEN #57, BigRIPS: #3059
01:14 Statistics shown as attachment #3, 08JunStats.png
1:32 AIDA R7_195 at stop of runs
1:33 AIDA R7_196, BRIKEN #58, BigRIPS #3060
System wide checks all okay.
2:01 Operators called: RF is down. It should be recovered in a short time. AIDA R7_202 at that time.
Biases and leak currents as attachment #4, 08JunBias2.png
2:07 Beam is back. AIDA R7_203 at that time
2:29 Biases shown as attachment #5, 8JunBias2.png
Analysis of R7_207 as attachment #6,analysis_R7_207.txthon
4 MBS timewarps seen, no global timewarps
All system-wide checks are passed.
(Beam was stopped for a couple minutes here)
2:38 AIDA R7_210 at run change-over
2:39 AIDA R7_210 (same); BRIKEN #59, BigRIPS #3061
All system wide checks are passed, with similar information as before.
FEE temps look okay, see attachment #7, 08JunTemp1.png
3:30 AIDA R7_221 at run change-over
All system-wide checks are passed
3:31 AIDA R7_221, BRIKEN #60, BigRIPS #3061
3:59 Phone rings, AIDA R7_228 RF drops again
4:03 Beam is back, AIDA R7_228 still
4:34 Biases and leak currents shown as attachment #8, 08JunBias3.png
R7_236 at AIDA just began during the changeover
4:38 AIDA R7_236 still, BRIKEN run #61, BigRIPS run #3062
All system wide checks are passed.
Analysis shown as R7_235.txt attachment #9
No timewarps, no MBS timewarps
5:30 AIDA R7_247 at changeover
All system-wide checks are passed
5:51 AIDA R7_252
NB: BRIKEN and AIDA are not synchronized
5:58 AIDA R7_253, BRIKEN #62; BigRIPS #3066
Now they are synchronized
6:11 Biases and leak currents shown as 08JunBias4.png, attachment #10
7:05 AIDA R7_268 at run changeover
All system wide checks are passed as normal
Now BRIKEN #63; BigRIPS 3067
Statistics shown as attachment #11 08JunStats2.png
Warp data shown as attachment #12 R7_268.txt
no warps, no MBS warps
8:00 Biases and leak currents shown as 08JunBias5.png, attachment #13
R7_280 at run changeover
BRIKEN #64; BigRIPS #3067 |
Wed Jun 7 08:02:42 2017, OH, PV, Wednesday 7 June 16:00 - 24:00 15x
|
16:02 System wide checks ok
Good Events statistics (No beam at time!)- attachment 1
Fee temperatures - attachment 2
Bias and leakage ok - attachment 3
16:29 BigRIPS starts run 3051
BRIKEN starts run 49
AIDA on file R7_80
Slits brought in to reduce rate to attempt implant-neutron correlation
16:39 DSSD rates from R7_81
*** DSSSD # 1 count: 182087 old count: 144548 dt: 1.02 s LEC rate: 36716.57 Hz
*** DSSSD # 2 count: 295938 old count: 235754 dt: 1.02 s LEC rate: 58865.45 Hz
*** DSSSD # 3 count: 80412 old count: 64397 dt: 1.02 s LEC rate: 15664.13 Hz
*** DSSSD # 4 count: 94793 old count: 75541 dt: 1.02 s LEC rate: 18830.22 Hz
*** DSSSD # 5 count: 23432 old count: 18547 dt: 1.02 s LEC rate: 4777.98 Hz
*** DSSSD # 6 count: 66315 old count: 53096 dt: 1.02 s LEC rate: 12929.39 Hz
*** DSSSD # 1 count: 0 old count: 0 dt: 1.02 s HEC rate: 0.00 Hz
*** DSSSD # 2 count: 8 old count: 4 dt: 1.02 s HEC rate: 3.91 Hz
*** DSSSD # 3 count: 23 old count: 20 dt: 1.02 s HEC rate: 2.93 Hz
*** DSSSD # 4 count: 38 old count: 32 dt: 1.02 s HEC rate: 5.87 Hz
*** DSSSD # 5 count: 13 old count: 10 dt: 1.02 s HEC rate: 2.93 Hz
*** DSSSD # 6 count: 11 old count: 8 dt: 1.02 s HEC rate: 2.93 Hz
17:13 BigRIPS and BRIKEN stop DAQS
AIDA on file R7_89
17:30 Beam back
BigRIPS starts run 3052
BRIKEN starts run 50
AIDA on file R7_93
17:52 Analysis of R7_93 No timewarps, no MBS timewarps - attachment 4
18:06 System wide checks all ok
Bias and leakage ok - attachment 5
Good events statistics - attachment 6
FEE temperatures ok - attachment 7
18:27 fRC problem, beam is off
18:29 BigRIPS and BRIKEN stop DAQS
AIDA on file R7_106
18:32 Beam is back
BigRIPS starts run 3053
BRIKEN starts run 51
AIDA on file R7_106
19:33 BigRIPS and BRIKEN stop daqs
AIDA on file R7_119
19:34 BRIKEN starts run 52
BigRIPS starts run 3054
AIDA on file R7_120
20:09 System wide checks ok
Bias and leakage ok - attachment 8
Good event statistics - attachment 9
Fee temperatures - attachment 10
20:28 BigRIPS and BRIKEN stop their DAQs
AIDA on file R7_131
20:30 BigRIPS starts run 3055
BRIKEN starts run 53
AIDA on file R7_131
20:41 Layout 3 - attachment 11
1.8.L spectrum for each FEE
Appears to be 4-5 pulser peaks
21:31 BRIKEN and BigRIPS stop their daqs
AIDA on file R7_144
21:32 BRIKEN starts run 54
BigRIPS starts run 2056
AIDA on file R7_144
22:03 System wide checks ok
Bias and leakage ok - attachment 12
Good events statistics - attachment 13
Fee temperatures - attachment 14
22:32 Briken and BigRIPS stop their daqs
AIDA on file R7_156
22:33 BigRIPS starts run 3057
BRIKEN starts run 55
AIDA on file R7_156
23:31 BigRIPS and BRIKEN stop their DAQs
AIDA on file R7_169
23:32 BigRIPS starts run 3058
BRIKEN starts run 56
AIDA on file R7_169
23:46 Analysis of R7_168 - attachmemt 15 |
Wed Jun 7 00:10:24 2017, NN, TD, Wednesday 7 June 08:00 - 16:00 30x
|
08:12 Analysis of file RIBF128/R6_438 - zero timewarps, four MBS timewarps - see attachment 1
08:23 Online analysis (per DSSSD rates) of R6_443, see attachment 2
08:35 BigRIPS and BRIKEN stop their DAQ
AIDA run file R6_446
08:40 BRIKEN starts run 043
BigRIPS starts run 3040
AIDA on file R6_448
09:16 *All* system wide checks OK
FEE64 Temperatures OK - see attachment 3
Good events statistics OK - see attachment 4
Detector biases & leakage currents OK - see attachment 5
Merger and tape server running - see attachment 6,7
09:51 Beam is OFF, RC is down
09:53 BigRIPS and BRIKEN stop their DAQ
AIDA run file R6_470
10:00 Beam is ON
10:01 BRIKEN starts run 044
BigRIPS starts run 3041
AIDA on file R6_472
10:07 AIDA DAQ crashed (fuse blown)
AIDA on file R6_474
10:14 BigRIPS and BRIKEN stop their QAD
AIDA on file R6_474
10:25 E17/F11 ambient temperature +24.3 deg C, RH 42.7%, d.p. +10.9 deg C
Julabo FL11006 set point +20 deg C, actual +20.0 deg C, water level OK (c. 75%)
BNC PB-4 analogue output BNC T replaced by BNC-Lemo00 adaptor and Lemo00 T
11:08 AIDA DAQ running (recovered)
11:10 BRIKEN starts run 045
BigRIPS starts run 3043
AIDA on file R7_1
(BigRIPS run 3042 was used to check synchronization)
11:21 *All* system wide checks OK
FEE64 Temperatures OK - see attachment 8
Good events statistics OK - see attachment 9
Detector biases & leakage currents OK - see attachment 10
Merger and tape server running - see attachment 11,12
11:28 Analysis of file RIBF128/R7_4 - zero timewarps, two MBS timewarps - see attachment 13
12:13 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_16
12:13 BRIKEN starts run 046
BigRIPS starts run 3044
AIDA on file R7_17
12:21 Analysis of file RIBF128/R7_15 - zero timewarps, two MBS timewarps - see attachment 14
12:23 High Energy Correlation spectra - see attachment 15
AIDA on file R7_20
13.00 Detector biases & leakage currents OK - see attachments 16 & 17
FEE64 Temperatures OK - see attachment 18
good events statistics OK - see attachment 19
No warnings/errors reported by merger since DAQ GO - see attachment 20
*all* system wide checks OK
13.06 analysis of file RIBF128/R7_30 - dead time < 0.5%, 0 ts & 1 MBS timewarps - see attachment 21
13.10 online analysis - ADC data synchronised - see attachment 22
per DSSSD HEC x versus y spectra - see attachment 23
per DSSSD HEC E_p versus E_n spectra - see attachment 24
13.12 per DSSSD rates file RIBF128/R7_33
*** DSSSD # 1 count: 100283 old count: 52419 dt: 1.00 s LEC rate: 47699.10 Hz
*** DSSSD # 2 count: 143318 old count: 73956 dt: 1.00 s LEC rate: 69123.04 Hz
*** DSSSD # 3 count: 61925 old count: 31310 dt: 1.00 s LEC rate: 30509.53 Hz
*** DSSSD # 4 count: 42834 old count: 21364 dt: 1.00 s LEC rate: 21396.03 Hz
*** DSSSD # 5 count: 10974 old count: 5692 dt: 1.00 s LEC rate: 5263.80 Hz
*** DSSSD # 6 count: 29846 old count: 15307 dt: 1.00 s LEC rate: 14488.91 Hz
*** DSSSD # 1 count: 3 old count: 1 dt: 1.00 s HEC rate: 1.99 Hz
*** DSSSD # 2 count: 34 old count: 23 dt: 1.00 s HEC rate: 10.96 Hz
*** DSSSD # 3 count: 96 old count: 51 dt: 1.00 s HEC rate: 44.84 Hz
*** DSSSD # 4 count: 85 old count: 51 dt: 1.00 s HEC rate: 33.88 Hz
*** DSSSD # 5 count: 8 old count: 4 dt: 1.00 s HEC rate: 3.99 Hz
*** DSSSD # 6 count: 8 old count: 4 dt: 1.00 s HEC rate: 3.99 Hz
all SortSas spectra & histograms zero'd
13.13 DAQ stop
AIDA run file R7_33
13.15 BRIKEN starts run 47
BigRIPS starts run 3045 *** N.B. by mistake BRIKEN DAQ not actually started ***
AIDA on file R7_ 33
BNC PB-4
Amplitude 90,000
x5 attenuator IN
t_r 100ns tau_d 50us
- polarity
frequency 25Hz range
delay MIN, tail pulse, INT ref
ASIC settings 2017Mar27-16.12.39
84Zn BigRIPS setting, 130Ag degrader setting - 2mm Al (in F7) + 3mm fixed + 1mm variable (in F11) = 6 mm Al
13.23 Beam stop to fix problem with STQ
DAQ stop
AIDA file RIBF128/R7_35
14:00 Beam is ON
AIDA file R7_43
14:01 BRIKEN starts run 48
BigRIPS starts run 3046
AIDA on file R7_ 44
14:48 Detector biases & leakage currents OK - see attachment 25
14:56 *All* system wide checks OK
FEE64 Temperatures OK - see attachment 26
Good events statistics OK - see attachment 27
Merger and tape server running - see attachment 28,29
15:16 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_64
15:25 Analysis of file RIBF128/R7_60 - zero timewarps, zero MBS timewarps - see attachment 30 |
Tue Jun 6 15:59:19 2017, DK, Wed 7 June night shift 14x
|
7 June 2017
00:05 All system-wide checks are passed
Sync pulses nera 44 x 10^6
Memory 35k ~ 38k
Biases uploaded as 33.png, 34.png - attachments 1 & 2
Entered into spreadsheet
SSD 3 bias is going up slowly since this isotope setting began
Around "2 to 4" Hz in SSDs 3 and 4 -> 50 to 80 pps implant rate
See attachment 3, 35.png
All rates under 100k except nnaida 13, 21
See attachment 4, 36.png
FEE temperatures shown as 37.png, attachment #5
00:30 BRIKEN number 32, AIDA R6_299, BigRIPS 3032
01:01 Timewarps look okay (only 2 MBS seen in FEE 6)
See R6_307 - attachment #6
01:30 BRIKEN and BigRIPS runs stopped. AIDA R6_317 at that time.
01:31 AIDA R6_318, BRIKEN run #33, BigRIPS #3033
All system-wide checks passed.
SYNC pulses 46 x 10^6
Memory 35 ~ 39k
02:08 Biases shown as 38.png, attachment #7
02:34 AIDA run R6_337 when BRIKEN and BigRIPS runs are stopped.
AIDA passes all system-wide checks.
02:37 AIDA just begins R6_338l. BRIKEN run #34, BigRIPS #3034
Timewarps look okay, see attachment #8, R6_336
Statistics consistent, see attachment #9, 39.png
Implant rate around 75 cps
03:31 AIDA run R6_354 at the stop of BRIKEN and BigRIPS runs
03:34 AIDA R6_355, BRIKEN run #35, BigRIPS #3035
AIDA passed all system checks. Merger shows low rate for nnaida8, but this is consistent for tonight.
4:03 Biases shown as 40.png, attachment #10.
4:08 Stats shown as 41.png, attachment #11
As before, only nnaida13 and nnaida21 show over 100k, and nnaida8 is quite low.
4:30 AIDA run R6_372 at the close of BRIKEN and BigRIPS runs.
4:32 AIDA R6_373 with new BRIKEN run #36 and BigRIPS #3036.
All system-wide checks okay.
5:38 AIDA R6_393 at the stop of BRIKEN and BigRIPS runs
All system-wide checks okay.
5:39 AIDA still R6_393, BRIKEN run #37 and BigRIPS run #3037
6:00 Leak currents shown as 42.png, attachment #12
6:16 Beam stopped so we can check the signal of one Ge detector that became noisy
R6_404 at that time
Added some Al foil to the Ge signal cables
6:28 Beam is back R6_408
6:29 BRIKEN run #41, BigRIPS #38
7:28 AIDA R6_426 at stop of other runs
System-wide checks are okay.
7:30 AIDA R6_427. BRIKEN #42, BigRIPS #39
Implant rates 60 ~ 70 cps in AIDA
One MBS timewarp in R6_426, as attachment #13
7:57 Leak currents shown as attachment #14, 43.png |
Tue Jun 6 15:26:44 2017, TD, ZL, Tuesday 06 June 16.00-24.00 29x
|
15.53 Bias and leakage currents ok - attachments 1 & 2
FEE temperatures ok - attachment 3
statistics good events still seeing noise on 13 and 14 - attachment 4
No merger errors since GO - attachment 5
16:00 all system wide checks OK
15:59 BigRIPS and BRIKEN stop daqs
AIDA on file R6_147
16:02 BigRIPS starts run 3023
BRIKEN starts run 23
AIDA on file R6_148
implant hit pattern statistics until the end of R6_147: attachment6 spectra cleared
17:00 BigRIPS and BRIKEN stop daqs
AIDA on file R6_165
17:02 BigRIPS starts run 3024
BRIKEN starts run 24
AIDA on file R6_166
18:03 BigRIPS and BRIKEN stop daqs
AIDA on file R6_183
18.04 BigRIPS starts run 3025
BRIKEN starts run 25
AIDA on file R6_184
18.18 Detector biases & leakage currents OK - see attachments 8 & 9
FEE64 Temperatures OK - see attachment 10
good events statistics OK - high but relatively stable - see attachment 11
No warnings/errors reported by merger since DAQ GO - see attachment 12
*all* system wide checks OK
18.23 analysis of file RIBF128/R6_188 - dead time < 0.5%, 0x ts timewarps, 1x MBS timewarps - see attachment 13
online analysis per DSSSD HEC x versus y spectra - see attachment 14
18.28 offline analysis R6_196 - ADC & disc data synchronised - see attachment 14
rates ***
DSSSD # 1 count: 579778 old count: 507154 dt: 1.02 s LEC rate: 71359.29 Hz ***
DSSSD # 2 count: 824589 old count: 719407 dt: 1.02 s LEC rate: 103350.31 Hz
DSSSD # 3 count: 344253 old count: 299859 dt: 1.02 s LEC rate: 43620.90 Hz ***
DSSSD # 4 count: 241567 old count: 210328 dt: 1.02 s LEC rate: 30694.99 Hz ***
DSSSD # 5 count: 70435 old count: 61399 dt: 1.02 s LEC rate: 8878.64 Hz ***
DSSSD # 6 count: 154453 old count: 135358 dt: 1.02 s LEC rate: 18762.47 Hz ***
DSSSD # 1 count: 4 old count: 2 dt: 1.02 s HEC rate: 1.97 Hz ***
DSSSD # 2 count: 113 old count: 96 dt: 1.02 s HEC rate: 16.70 Hz ***
DSSSD # 3 count: 437 old count: 386 dt: 1.02 s HEC rate: 50.11 Hz ***
DSSSD # 4 count: 341 old count: 288 dt: 1.02 s HEC rate: 52.08 Hz ***
DSSSD # 5 count: 53 old count: 46 dt: 1.02 s HEC rate: 6.88 Hz ***
DSSSD # 6 count: 35 old count: 31 dt: 1.02 s HEC rate: 3.93 Hz
all SortSas spectra and histograms zero'd
19.01 BigRIPS and BRIKEN stop daqs
AIDA on file R6_201
19.02 BigRIPS starts run 3026
BRIKEN starts run 26
AIDA on file R6_201
20:00 Detector biases & leakage currents OK - see attachments 20 & 21
FEE64 Temperatures OK - see attachment 22
merger data rate -- - see attachment 23
good events statistics OK - high but relatively stable - see attachment 24, 26
implantation profiles - see attachment 25
*all* system wide checks OK
20:02 BigRIPS and BRIKEN stop daqs
AIDA on file R6_219
20:02 BigRIPS starts run 3027
BRIKEN starts run 27
AIDA on file R6_220
21:02 BigRIPS and BRIKEN stop daqs
AIDA on file R6_237
20:03 BigRIPS starts run 3028
BRIKEN starts run 28
AIDA on file R6_237
21.21 beam lost during R6_243
BigRIPS and BRIKEN stop daqs
AIDA on file R6_243
21:24 beam back
21:25 BigRIPS starts run 3029
BRIKEN starts run 29
AIDA on file R6_244
22:26 BigRIPS and BRIKEN stop daqs
AIDA on file R6_262
22:28 BigRIPS starts run 3030
BRIKEN starts run 30
AIDA on file R6_263
22:36 Detector biases & leakage currents OK
FEE64 Temperatures OK
merger data rate good events statistics OK - high but relatively stable implantation profiles
for the details see attachments 27-32
23:05 beam lost
23:08 beam back
23:28 BigRIPS and BRIKEN stop daqs
AIDA on file R6_281
23:29 BigRIPS starts run 3031
BRIKEN starts run 31
AIDA on file R6_281 |
Tue Jun 6 07:44:19 2017, TD, Preamplifier waveforms 25x
|
Preamplifier waveforms sampled by 50MSPS, 14 bit ADC
attachment 1 - nnaida13 ASIC settings (+ input)
attachment 2 - nnaida16 ASIC settings (- input)
beam on
-------
attachments 3-5 - three successive waveform updates nnaida13 asic #1 - 1000ch = 20us
attachments 6-8 - three successive waveform updates nnaida13 asic #1 - 1000ch = 2ms
attachments 9-11 - three successive waveform updates nnaida16 asic #1 - 1000ch = 20us
attachments 12-14 - three successive waveform updates nnaida16 asic #1 - 1000ch = 2ms
beam off
--------
attachments 15-18 - three successive waveform updates nnaida13 asic #1 - 1000ch = 2ms
attachments 19-21 - three successive waveform updates nnaida16 asic #1 - 1000ch = 2ms
attachments 22-23 - three successive waveform updates nnaida16 asic #1 - 1000ch = 2ms, y-scale expanded
attachments 24-25 - three successive waveform updates nnaida13 asic #1 - 1000ch = 2ms, y-scale expanded |
Tue Jun 6 00:57:49 2017, PJW, TD, Tuesday 6 June 08.00-16.00 16x
|
08.57 Stop DAQ
AIDA file RIBF128/R6_24
09.00 BigRips starts run 3016
BRIKEN starts run 16
AIDA on file R6_25
09:23 biases and leakage currents recorded attachments 1 and 2
09.36 online spectra per DSSSD x versus y (HEC) - see attachment 3
per DSSSD E_p versus E_n (HEC) - see attachment 4
09.39 offline analysis RIBF128/R6_36
ADC & disc data synchronised - see attachment 5
rates
*** DSSSD # 1 count: 475974 old count: 407247 dt: 1.04 s LEC rate: 66335.14 Hz
*** DSSSD # 2 count: 695537 old count: 595776 dt: 1.04 s LEC rate: 96289.08 Hz
*** DSSSD # 3 count: 284002 old count: 245156 dt: 1.04 s LEC rate: 37494.07 Hz
*** DSSSD # 4 count: 197428 old count: 169943 dt: 1.04 s LEC rate: 26528.46 Hz
*** DSSSD # 5 count: 58436 old count: 49831 dt: 1.04 s LEC rate: 8305.53 Hz
*** DSSSD # 6 count: 130742 old count: 111691 dt: 1.04 s LEC rate: 18387.98 Hz
*** DSSSD # 1 count: 2 old count: 2 dt: 1.04 s HEC rate: 0.00 Hz
*** DSSSD # 2 count: 92 old count: 82 dt: 1.04 s HEC rate: 9.65 Hz
*** DSSSD # 3 count: 387 old count: 332 dt: 1.04 s HEC rate: 53.09 Hz
*** DSSSD # 4 count: 281 old count: 251 dt: 1.04 s HEC rate: 28.96 Hz
*** DSSSD # 5 count: 37 old count: 31 dt: 1.04 s HEC rate: 5.79 Hz
*** DSSSD # 6 count: 36 old count: 33 dt: 1.04 s HEC rate: 2.90 Hz
all SortSas spectra and online histograms zero'd
09.48 analysis RIBF128/R6_35 deadtime <0.5%, zero ts timewarps, 2 MBS timewarps - see attachment 6
10.00 FEE64 temperatures OK - see attachment 7
good events stats - see attachment 8
merger - no error/warning messages - see attachment 9
nnaida13 waveforms ASICS 1-4 100*20us = 2ms range - see attachments 10-13
10.00 Stop DAQ
AIDA file RIBF128/R6_42
10.01 BigRips starts run 3017
BRIKEN starts run 17
AIDA on file R6_43
10.09 *all* system wide checks OK
11:00 stop daq
aida file r6_59
11.01 BigRips starts run 3018
BRIKEN starts run 18
AIDA on file R6_60
11:59 stop daq
aida file R6_76
12:01 Bigrips starts run 3019
BRIKEN starts run 19
aida on file R6_77
12:59 stop daq
aida file R6_94
13:01 Bigrips starts run 3020
BRIKEN starts run 20
aida on file R6_95
13.51 biases and leakage currents recorded attachments 15 & 16
14:00 stop daq
aida file R6_112
14:03 Bigrips starts run 3021
BRIKEN starts run 21
aida on file R6_113
14:57 beam stopped
15:00 stop daq
aida file R6_130
15:01 beam back
15:02 Bigrips starts run 3022
BRIKEN starts run 22
aida on file R6_130 |
Mon Jun 5 16:02:50 2017, OH, PV, AE, Tuesday 06 June 00.00-08.00 40x
|
00:03 BigRIPS starts run 3007
BRIKEN starts run 007
AIDA on file R5_146
00:07 Bias and leakage currents ok - attachment 1
System wide checks all ok
FEE temperatures ok - attachment 2
Good evts still seeing noise on 13 and 14 - attachment 3
No merger errors since GO
00:48 DSSD Rates from R5_160
*** DSSSD # 1 count: 250904 old count: 163089 dt: 1.02 s LEC rate: 86326.91 Hz
*** DSSSD # 2 count: 335185 old count: 222784 dt: 1.02 s LEC rate: 110496.28 Hz
*** DSSSD # 3 count: 157445 old count: 103991 dt: 1.02 s LEC rate: 52548.18 Hz
*** DSSSD # 4 count: 102079 old count: 67878 dt: 1.02 s LEC rate: 33621.44 Hz
*** DSSSD # 5 count: 40500 old count: 26651 dt: 1.02 s LEC rate: 13614.32 Hz
*** DSSSD # 6 count: 64652 old count: 42396 dt: 1.02 s LEC rate: 21878.85 Hz
*** DSSSD # 1 count: 0 old count: 0 dt: 1.02 s HEC rate: 0.00 Hz
*** DSSSD # 2 count: 41 old count: 27 dt: 1.02 s HEC rate: 13.76 Hz
*** DSSSD # 3 count: 161 old count: 103 dt: 1.02 s HEC rate: 57.02 Hz
*** DSSSD # 4 count: 131 old count: 85 dt: 1.02 s HEC rate: 45.22 Hz
*** DSSSD # 5 count: 22 old count: 12 dt: 1.02 s HEC rate: 9.83 Hz
*** DSSSD # 6 count: 9 old count: 6 dt: 1.02 s HEC rate: 2.95 Hz
01:02 Briken and BigRIPS daq stops
01:03 Briken Starts run 8
BigRIPS starts run 3008
01:40 Phong noticed a significant difference in the noise in the (raw) low energy spectra a few of the FEEs when
comparing the runs right before and right after the power-cycle (See Attachment 12) required to recover
the DAQ crash last afternoon (June 5th).
NNAIDA 22, 21, 14, and 13 had a much higher count rate after the power cycle, and what seems like a lower
threshold. We can't observe the pulser peak in any of those.
NNAIDA 13 has the highest count rate, and the waveforms show what looks like noise with a regular
frequency (attachments 4 - 7)
For reference, we include the waveform of other positive FEEs 8-11
02:51 Bias and leakages ok - attachment 13
System wide checks ok
Good Event statistics - attachment 14
Fee Temperatures - attachment 15
03:03 BigRIPS and BRIKEN stop daqs
AIDA on file R5_208
03:04 BigRIPS starts run 3009
BRIKEN starts run 9
AIDA on file R5_208
04:03 BigRIPS and BRIKEN stop daqs
AIDA on file R5_230
04:04 BigRIPS starts run 3010
BRIKEN starts run 10
AIDA on file R5_230
04:09 System wide checks all ok
Bias and leakages ok - attachment 16
Fee Temperatures - attachment 17
Good Event Statistics - attachment 18
04:48 DSSD rates from R5_244
*** DSSSD # 1 count: 1239207 old count: 1155424 dt: 1.04 s LEC rate: 80379.42 Hz
*** DSSSD # 2 count: 1684042 old count: 1567549 dt: 1.04 s LEC rate: 111760.61 Hz
*** DSSSD # 3 count: 806937 old count: 752064 dt: 1.04 s LEC rate: 52643.85 Hz
*** DSSSD # 4 count: 505814 old count: 472642 dt: 1.04 s LEC rate: 31824.43 Hz
*** DSSSD # 5 count: 208086 old count: 193231 dt: 1.04 s LEC rate: 14251.53 Hz
*** DSSSD # 6 count: 335686 old count: 313190 dt: 1.04 s LEC rate: 21582.13 Hz
*** DSSSD # 1 count: 8 old count: 7 dt: 1.04 s HEC rate: 0.96 Hz
*** DSSSD # 2 count: 193 old count: 181 dt: 1.04 s HEC rate: 11.51 Hz
*** DSSSD # 3 count: 872 old count: 810 dt: 1.04 s HEC rate: 59.48 Hz
*** DSSSD # 4 count: 637 old count: 601 dt: 1.04 s HEC rate: 34.54 Hz
*** DSSSD # 5 count: 89 old count: 81 dt: 1.04 s HEC rate: 7.68 Hz
*** DSSSD # 6 count: 71 old count: 65 dt: 1.04 s HEC rate: 5.76 Hz
05:01 BRIKEN and BigRIPS stop DAQs
AIDA on file R5_250
05:02 BigRips starts run 3011
BRIKEN starts run 11
AIDA on file R5_250
06:02 BigRIPS and BRIKEN stop their daqs
AIDA on file R5_272
06:03 BigRIPS starts run 3012
BRIKEN starts run 12
AIDA on file R5_272
06:06 System wide checks all ok
Bias and leakage currents ok - attachment 19
Good event statistics - attachment 20
FEE temperatures ok - attachment 21
06:16 Analysis of R5_270 - attachment 22
Three MBS errors
06:34 130Cd decay curve - attachments 22 and 23
Despite the large amounts of noise in the detectors it is still possible to observe decay curves. They are
cleaned up a lot
by applying a multiplicity cut (attachment 22 with attachment 23 without. Further cuts and vetos could be
applied to clean up further.
The fit in attachment 22 gives a half life of 182ms which is not quite the expected 162ms but a reasonable
first fit.
07.14 Layout - 1.8.W waveforms - see attachments 24-27
No significant change in intrinsic/extrinsic noise cf. previous screenshots
nnaida13 ASIC 1-4 waveforms - see attachments 28-31 - range 100*20us
07.24 BRIKEN and BigRIPS stop DAQs
AIDA on file R5_300
07.25 Stop AIDA DAQ
Cycle detector biases
Start AIDA DAQ
07.38 BigRips starts run 3014
BRIKEN starts run 14
AIDA on file R6_1
07.45 nnaida13 ASIC 1-4 waveforms - see attachments 32-35 - range 100*20us
08.07 all system wide checks OK |
Mon Jun 5 08:43:24 2017, CB, TD, PW, DK, Monday 5 June 16:00 to 24:00 38x
|
16:43 Leakage currents OK - see attachment 1
FEE64 temperatures OK - see attachment 2
Statistics show rate increase in nnaida13, 21. Reason unclear - see attachment 3
Waveforms for nnaida13 look OK - see attachment 4
No merger errors - see attachment 5
All system-wide checks OK, except ADC calibration for nnaida1, 8, 19
Current writing speed 10 Mb/s, 30% higher than before - see attachment 6
Current AIDA run /TapeData/RIBF128/R5_6
17:50 Leakage currents OK - see attachment 7
FEE64 temperatures OK - see attachment 8
Statistics as before - see attachment 9
No merger errors - see attachment 10
Analysed /TapeData/RIBF128/R5_25 - attachment 11
Rate high as expected, no timewarps, negligible dead time, idle time in agreement with dead time
19.34 DAQ starts
AIDA file RIBF128/R5_58
BigRIPS file 2088
BRIKEN file 0
BNC PB-4
Amplitude 90,000
x5 attenuator IN
t_r 100ns tau_d 50us
- polarity
frequency 25Hz range
delay MIN, tail pulse, INT ref
ASIC settings 2017Mar27-16.12.39
130Ag BigRIPS setting, degrader setting - fixed 6mm (in F11) + variable all out = 6 mm Al
19.38 DAQ stops
AIDA file RIBF128/R5_59
20.04 Detector biases & leakage currents OK - see attachments 12 & 13
FEE64 Temperatures OK - see attachment 14
good events statistics OK - see attachment 15
No warnings/errors reported by merger since DAQ GO - see attachment 16
*all* system wide checks OK (zero fails)
analysis of file RIBF128/R5_67 - dead time < 0.5%, no timewarps, 2 MBS timewarps - see attachment 17
20.14 online analysis - ADC & disc data synchronised - see attachment 18
20.28 layout spectra - attachments 19-28
no pulser peaks observed in p+n junction strip FEE64s - to be checked when access is obtained
21.01 E17/F11 ambient temperature +24.3 deg C, RH 41.0%, d.p. +10.0 deg C
Julabo FL11006 set point +20 deg C, actual +20.0 deg C, water level OK (c. 75%)
21.07 DAQ starts
AIDA file RIBF128/R5_85
BigRIPS file 3003
BRIKEN file 3
BNC PB-4
Amplitude 90,000
x5 attenuator IN
t_r 100ns tau_d 50us
- polarity
frequency 25Hz range
delay MIN, tail pulse, INT ref
ASIC settings 2017Mar27-16.12.39
130Ag BigRIPS setting, degrader setting - fixed 2mm Al at F7, fixed 3mm + variable 1mm Al at F11 = 6 mm Al
21.15 DAQ stop
AIDA file RIBF128/R5_88
21.31 DAQ starts
AIDA file RIBF128/R5_93
BigRIPS file 3004
BRIKEN file 4
DAQ sync check OK
All SortSas spectra & histograms zero'd
21.45 DAQ stop
AIDA file RIBF128/R5_98
21.31 DAQ starts
AIDA file RIBF128/R5_98
BigRIPS file 3005
BRIKEN file 5
22.00 Detector biases & leakage currents OK - see attachments 29 & 30
FEE64 Temperatures OK - see attachment 31
good events statistics OK - see attachment 32
No warnings/errors reported by merger since DAQ GO - see attachment 33
*all* system wide checks OK (zero fails)
analysis of file RIBF128/R5_67 - dead time < 0.7%, no timewarps, 1 MBS timewarp - see attachment 34
20.14 online analysis - ADC & disc data synchronised - see attachment 35
22.08 offline analysis file RIBF128/R5_106 - rates
*** DSSSD # 1 count: 403476 old count: 321247 dt: 1.03 s LEC rate: 80056.89 Hz
*** DSSSD # 2 count: 559009 old count: 446189 dt: 1.03 s LEC rate: 109839.82 Hz
*** DSSSD # 3 count: 262328 old count: 206447 dt: 1.03 s LEC rate: 54404.88 Hz
*** DSSSD # 4 count: 159863 old count: 127957 dt: 1.03 s LEC rate: 31063.19 Hz
*** DSSSD # 5 count: 66930 old count: 52878 dt: 1.03 s LEC rate: 13680.81 Hz
*** DSSSD # 6 count: 109482 old count: 87597 dt: 1.03 s LEC rate: 21306.90 Hz
*** DSSSD # 1 count: 1 old count: 1 dt: 1.03 s HEC rate: 0.00 Hz
*** DSSSD # 2 count: 72 old count: 56 dt: 1.03 s HEC rate: 15.58 Hz
*** DSSSD # 3 count: 278 old count: 214 dt: 1.03 s HEC rate: 62.31 Hz
*** DSSSD # 4 count: 218 old count: 178 dt: 1.03 s HEC rate: 38.94 Hz
*** DSSSD # 5 count: 22 old count: 18 dt: 1.03 s HEC rate: 3.89 Hz
*** DSSSD # 6 count: 27 old count: 15 dt: 1.03 s HEC rate: 11.68 Hz
online analysis - per DSSSD x versus y (HEC) - attachment 36
per DSSSD E_p versus E_n (HEC) - attachment 37
offline analysis file RIBF128/R5_106 - ADC & disc data synchronised - attachment 38
N.B. pulser to p+n strips appears to be low amplitude - absence of secondary ADC peak, low multiplicity for
disc data
23.01 DAQ stop
AIDA file RIBF128/R5_124
23.02 DAQ starts
AIDA file RIBF128/R5_124
BigRIPS file 3006
BRIKEN file 6
00:01 DAQ stop
AIDA file R5_145 |
Sun Jun 4 23:50:24 2017, CB, PW, DK, TD, Monday 5 June 08:00 to 16:00 24x
|
07:50 Leakage currents OK - attachment 1
FEE64 temperatures OK - attachment 2
Good event statistics OK - attachment 3
No new merger errors - attachment 4
HEC x vs y plot OK - attachment 5
Zero'd SortSas
Sorted run RIBF148/R2_375. DSSD rates as follows
Pulser still synchronised - attachment 6
*** data items: 13911095 ( 120732.29 Hz)
*** ADC events: 1173612 ( 10185.60 Hz)
*** time warps: 0 ( 0.00 Hz)
*** DSSSD # 1 count: 546264 old count: 529893 dt: 11.53 s LEC rate: 47387.36 Hz
*** DSSSD # 2 count: 811805 old count: 787055 dt: 11.53 s LEC rate: 70422.54 Hz
*** DSSSD # 3 count: 308448 old count: 297268 dt: 11.53 s LEC rate: 26757.28 Hz
*** DSSSD # 4 count: 246100 old count: 238286 dt: 11.53 s LEC rate: 21348.71 Hz
*** DSSSD # 5 count: 148961 old count: 143967 dt: 11.53 s LEC rate: 12922.08 Hz
*** DSSSD # 6 count: 240995 old count: 233066 dt: 11.53 s LEC rate: 20905.86 Hz
*** DSSSD # 1 count: 0 old count: 0 dt: 11.53 s HEC rate: 0.00 Hz
*** DSSSD # 2 count: 19 old count: 18 dt: 11.53 s HEC rate: 1.65 Hz
*** DSSSD # 3 count: 5 old count: 5 dt: 11.53 s HEC rate: 0.43 Hz
*** DSSSD # 4 count: 32 old count: 26 dt: 11.53 s HEC rate: 2.78 Hz
*** DSSSD # 5 count: 70 old count: 70 dt: 11.53 s HEC rate: 6.07 Hz
*** DSSSD # 6 count: 1403 old count: 1354 dt: 11.53 s HEC rate: 121.71 Hz
Analysed run R2_375. 6 MBS related errors messages, but no MBS timewarps. See attachment 7
08:01 BRIKEN and BigRIPS stopping run
AIDA on run RIBF148/R2_378
08:03 BRIKEN starts run 25
BigRIPS starts run 24
AIDA on run RIBF148/R2_379
08:26 All system wide checks OK *except* nnaida1 clock status (6), ADC calibration for nnaida1, 21
08:26 BRIKEN and BigRIPS stopping run
AIDA on run RIBF148/R2_387
08:26 Completely removing degraders
08:39 BRIKEN starts run 26
BigRIPS starts run 25
AIDA on run RIBF148/R2_388
Zero'd SortSas
08:55 HEC x vs y plot - attachment 8
09:00 BRIKEN and BigRIPS stopping run
AIDA on run RIBF148/R2_394
Rare earths first run ends here.
09:01 Stopped DAQ
09:20 Rebuilt lead wall in front of AIDA
T = 24.9C RH = 23.7% DP = 3.6C
Julabo Chiller at 75%. Refilled.
11:13 Restarted DAQ
Checkload x2 - All OK
Current run /TapeServer/RIBF128/R1_1
All OK
11:19 Starting run RIBF128/R2_1
High-amplitude pulser walkthrough 90 000, 80 000 ... 10 000
Frequency 250 Hz
11:31 Starting run RIBF128/R3_1
Low-amplitude pulser walkthrough 12 000, 10 000 ... 2 000
Frequency 250 Hz
Set pulser amplitude back to 90 000, frequency to 25 Hz
Stopped run
11:41 Starting new run RIBF128/R4_1
Background run at present
13.56 Detector biases & leakage currents OK - see attachments 9 & 10
FEE64 Temperatures OK - see attachment 11
good events statistics OK - see attachment 12
No warnings/errors reported by merger since DAQ GO - see attachment 13
*all* system wide checks OK *except* ADC calibration of nnaida1, 21 and nnaida1 clock status (status=6)
14.30 analysis of file RIBF128/R4_25 - dead time < 0.5% - see attachment 14
14.32 online analysis - ADC data synchronised - see attachment 15
15:08 Merger log shows repeated timewarps - attachment 16
Seems to have stopped now.
15:10 Analysed R4_38. 9 MBS timewarps.
Other parameters as normal
15:14 Analysed R4_39. 4 MBS timewarps.
Other parameters as normal.
15:19 ttyUSB18 (nnaida6) attached - attachment 17
Log is extremely large and contains several repetitions of one error message
TCP transfer library version 3.12
TCP socket send buffer was 16384 - now 221184
TCP socket receive buffer was 87380 - now 221184
TCP socket created OK - now connecting to myserver port 11006
Transfer Error - : Connection refused
connect() failed:
TCP transfer library version 3.12
TCP socket send buffer was 16384 - now 221184
TCP socket receive buffer was 87380 - now 221184
TCP socket created OK - now connecting to myserver port 11006
Transfer Error - : Connection refused
connect() failed:
TCP transfer library version 3.12
TCP socket send buffer was 16384 - now 221184
TCP socket receive buffer was 87380 - now 221184
TCP socket created OK - now connecting to myserver port 11006
Transfer Error - : Connection refused
15:25 Merger crashed. Stopped merger. Stopped tape server.
Merger shows all links bright green, except nnaida 2 - see attachment 20
Statistics show a counting spike in nnaida 2 - see attachment 21
15:33 Cannot reset the DAQ - see attachment 22
15:40 System console log for nnaida2 attached - see attach 23
15:54 Power cycled FEEs
Waited 10 minutes. nnaida13 did not mount /nfs - see attached log (attach 24)
16:07 Power cycled FEEs again. Managed to restart the DAQ. |
Sun Jun 4 16:00:49 2017, NN, OH, Monday 5 June 00:00 to 08:00 19x
|
23:59 BigRIPS and Briken stop their DAQ
AIDA run file R2_245
00:01 BRIKEN starts run 17
BigRIPS starts run 2016
AIDA on file R2_246
00:25 Analysis of file RIBF148/R2_250 - zero timewarps, four MBS timewarps - see attachment 1
00:37 per DSSSD rates file RIBF148/R2_250
*** DSSSD # 1 count: 768684 old count: 723417 dt: 1.03 s LEC rate: 43913.93 Hz
*** DSSSD # 2 count: 1122273 old count: 1056622 dt: 1.03 s LEC rate: 63688.64 Hz
*** DSSSD # 3 count: 427162 old count: 402923 dt: 1.03 s LEC rate: 23514.48 Hz
*** DSSSD # 4 count: 338200 old count: 317183 dt: 1.03 s LEC rate: 20388.79 Hz
*** DSSSD # 5 count: 204859 old count: 191893 dt: 1.03 s LEC rate: 12578.44 Hz
*** DSSSD # 6 count: 327506 old count: 307098 dt: 1.03 s LEC rate: 19797.99 Hz
*** DSSSD # 1 count: 3 old count: 3 dt: 1.03 s HEC rate: 0.00 Hz
*** DSSSD # 2 count: 46 old count: 43 dt: 1.03 s HEC rate: 2.91 Hz
*** DSSSD # 3 count: 7 old count: 6 dt: 1.03 s HEC rate: 0.97 Hz
*** DSSSD # 4 count: 32 old count: 30 dt: 1.03 s HEC rate: 1.94 Hz
*** DSSSD # 5 count: 77 old count: 72 dt: 1.03 s HEC rate: 4.85 Hz
*** DSSSD # 6 count: 1873 old count: 1748 dt: 1.03 s HEC rate: 121.26 Hz
01:00 BigRIPS and BRIKEN stop their DAQ
AIDA run file R2_262
01:02 BRIKEN starts run 18
BigRIPS starts run 2017
AIDA on file R2_263
01:43 Beam is OFF
01:45 Beam is ON
02:00 BigRIPS and BRIKEN stop their DAQ
AIDA run file R2_278
02:04 BRIKEN starts run 19
BigRIPS starts run 2018
AIDA on file R2_280
02:28 *All* system wide checks OK *except* ADC calibration of nnaida1, 21 and nnaida1 clock status (status=6)
FEE64 Temperatures OK - see attachment 2
Good events statistics OK - see attachment 3
Detector biases & leakage currents OK - see attachment 4
Merger and tape server still running - see attachment 5, 6
02:35 High energy correlation between x and y attachment 7
AIDA run R2_288
03:02 BigRIPS and BRIKEN stop their DAQ
AIDA run file R2_295
03:02 BRIKEN starts run 20
BigRIPS starts run 2019
AIDA on file R2_296
03:52 Analysis of file RIBF148/R2_305 - zero timewarps, two MBS timewarps - see attachment 8
03:59 BigRIPS and BRIKEN stop their DAQ
AIDA run file R2_311
04:02 BRIKEN starts run 21
BigRIPS starts run 2020
AIDA on file R2_312
04:59 BigRIPS and BRIKEN stop their DAQ
AIDA run file R2_328
05:02 BRIKEN starts run 22
BigRIPS starts run 2021
AIDA on file R2_329
05:11 *All* system wide checks OK *except* ADC calibration of nnaida1, 21 and nnaida1 clock status (status=6)
FEE64 Temperatures OK - see attachment 9
Good events statistics OK - see attachment 10
Detector biases & leakage currents OK - see attachment 11
Merger and tape server still running,No warnings/errors- see attachment 12, 13, 14
05:23 Analysis of file RIBF148/R2_332 - zero timewarps - see attachment 15
05:58 BigRIPS and BRIKEN stop their DAQ
AIDA run file R2_344
05:59 BRIKEN starts run 23
BigRIPS starts run 2022
AIDA on file R2_345
07:00 BigRIPS and BRIKEN stop their DAQ
AIDA run file R2_361
07:05 BRIKEN starts run 24
BigRIPS starts run 2023
AIDA on file R2_362
07:06 Detector biases & leakage currents OK - see attachment 16
07:12 All system wide checks OK except ADC calibration of nnaida1, 21 and nnaida clock status (status = 6)
FEE64 temperature OK - see attachment 17
Good event statistics OK - see attachment 18
Merger and tape server running, No warning/errors
07:17 Analysis of file RIBF148/R2_364 - zero timewarps, three MBS timewarps - see attachment 19
|
Sun Jun 4 08:13:10 2017, LHB, PV, NN, 4th June 16.00-00.00 28x
|
16.25 *All* system wide checks OK *except* ADC calibration of nnaida1, 21 and nnaida1 clock status (status=6)
FEE64 Temperatures OK - see attachment 1
Good events statistics OK - see attachment 2
Detector biases & leakage currents OK - see attachment 3
No warnings/errors reported by merger since DAQ GO - see attachment 4
16.30 Analysis file RIBF148/R2_122 - nnaida2 deadtime 0.9%, all other deadtimes <0.3%, zero timewarps, one MBS
timewarp - see attachment 5
16.44 BRIKEN and BigRIPS stop daqs
AIDA on file R2_127
16.47 BRIKEN starts run 9
BigRIPS starts run 2008
AIDA on file R2_128
17.08 Online analysis - per DSSSD HEC x versus y attachment 6
per DSSSD HEC E_p versus E_n - see attachment 7
17.44 BRIKEN and BigRIPS stop daqs
AIDA on file R2_143
17.46 BRIKEN starts run 10
BigRIPS starts run 2009
AIDA on file R2_144
18.00 BRIKEN and BigRIPS stop daqs
AIDA on file R2_147
18.02 BRIKEN starts run 11
BigRIPS starts run 2010
AIDA on file R2_148
18.15 *All* system wide checks OK *except* ADC calibration of nnaida1, 21 and nnaida1 clock status (status=6)
FEE64 Temperatures OK - see attachment 8
Good events statistics OK - see attachment 9
Detector biases & leakage currents OK - see attachment 10
No warnings/errors reported by merger since DAQ GO - see attachment 11
18.47 Online analysis - per DSSSD HEC x versus y attachment 12
per DSSSD HEC E_p versus E_n - see attachment 13
Zero online sort spectra
18.50 Analysis of file RIBF148/R2_159 - all deadtimes <0.5%, zero timewarps, four MBS timewarps - see attachment 14
19.04 BRIKEN and BigRIPS stop daqs
AIDA on file R2_165
19.07 BRIKEN starts run 12
BigRIPS starts run 2011
AIDA on file R2_166
20:00 BRIKEN and BigRIPS stop daqs
AIDA on file R2_180
20.02 BRIKEN starts run 13
BigRIPS starts run 2012
AIDA on file R2_180
Zero online sort spectra so we can monitor the influence on HEC x versus y due to the degrader just inserted.
20.15 *All* system wide checks OK *except* ADC calibration of nnaida1, 21 and nnaida1 clock status (status=6)
FEE64 Temperatures OK - see attachment 15
Good events statistics OK - see attachment 16
Detector biases & leakage currents OK - see attachment 17
No warnings/errors reported by merger since DAQ GO - see attachment 18
20.28 Analysis of file RIBF148/R2_185 - all deadtimes <0.4%, zero timewarps, three MBS timewarps - see attachment 19
20.58 Online analysis - per DSSSD HEC x versus y attachment 20
per DSSSD HEC E_p versus E_n - see attachment 21
Zero online sort spectra
21.02 BRIKEN and BigRIPS stop daqs
AIDA on file R2_197
21.03 BRIKEN starts run 14
BigRIPS starts run 2013
AIDA on file R2_197
22.02 BRIKEN and BigRIPS stop daqs
AIDA on file R2_213
22.03 BRIKEN starts run 15
BigRIPS starts run 2014
AIDA on file R2_214
22.17 *All* system wide checks OK *except* ADC calibration of nnaida1, 21 and nnaida1 clock status (status=6)
FEE64 Temperatures OK - see attachment 22
Good events statistics OK - see attachment 23
Detector biases & leakage currents OK - see attachment 24
No warnings/errors reported by merger since DAQ GO - see attachment 25
22.22 Analysis of file RIBF148/R2_218 - all deadtimes <0.5%, zero timewarps, four MBS timewarps - see attachment 26
22.45 Online analysis - per DSSSD HEC x versus y attachment 27
per DSSSD HEC E_p versus E_n - see attachment 28
Zero online sort spectra
23.04 BRIKEN and BigRIPS stop daqs
AIDA on file R2_230
23.05 BRIKEN starts run 16
BigRIPS starts run 2015
AIDA on file R2_231 |
Sun Jun 4 00:06:18 2017, OH, TD, PJW, Sunday 4 June 08.00-16.00 32x
|
08:00 DAQ found stopped at around 04:49 - Attachment 1
Time obtained from last file written as part of R1
Tape server still running - Attachment 2
Merger terminal contents - Attachment 3
FEE output from monitor for nnaida6 - Attachment 4
DAQ still passed all system wide checks after the crash
08:22 Merger recovered.
DAQ start
AIDA file RIBF148/R2
BNC PB-4
Amplitude 90,000
x5 attenuator IN
t_r 100ns tau_d 50us
- polarity
frequency 25Hz range
delay MIN, tail pulse, INT ref
ASIC settings 2017Mar27-16.12.39
08.35 Detector biases & leakage currents OK - see attachments 5 & 6
FEE64 Temperatures OK - see attachment 7
good events statistics OK - see attachment 8
No warnings/errors reported by merger since DAQ GO - see attachment 9
*all* system wide checks OK *except* ADC calibration of nnaida1, 21 and nnaida1 clock status (status=6)
ADC calibration reports for nnaida1 & nnaida21 - see attachments 10 & 11
08.50 E17/F11 ambient temperature +24.1 deg C, RH 25.1%, d.p. +2.9 deg C
Julabo FL11006 set point +20 deg C, actual +20.0 deg C, water level OK (c. 75%)
09.05 analysis of file RIBF148/R2_7 - deadtime <0.5%, no timewarps - see attachment 12
09.12 offline analysis RIBF148/R2_10 - ADC & disc data synchronised - see attachment 13
09.40 System stats showing aidas1 was 100% busy from c. 04.50 - see attachment 14
11.55 RIBF148 DAQ starts
BigRIPS setting 167Sm
AIDA file RIBF148/R2_48
BigRIPS file 2002
BRIKEN file 3
Degrader setting F11 3mm Al variable
BNC PB-4
Amplitude 90,000
x5 attenuator IN
t_r 100ns tau_d 50us
- polarity
frequency 25Hz range
delay MIN, tail pulse, INT ref
ASIC settings 2017Mar27-16.12.39
12.04 Detector biases & leakage currents OK - see attachments 15 & 16
12.29 DAQ stop
AIDA file RIBF148/R2_57
per DSSSD HEC x versus y - see attachment 17
12.32 RIBF148 DAQ starts
AIDA file RIBF148/R2_57
BigRIPS file 2003
BRIKEN file 4
13:00 Bias and leakage currents - attachment 18
13:29 BRIKEN and BigRIPS stop daqs
AIDA on file R2_73
13:31 BRIKEN stars run 5
BigRIPS starts run 2004
AIDA on file R2_274
No beam at start of run
14.00 Detector biases & leakage currents OK but rate of increase significantly increased due to higher A & Z -
see attachments 19 & 20
14.10 DAQ stop
AIDA file RIBF148/R2_84
per DSSSD HEC x versus y - see attachment 21
All SortSas spectra zero'd
14.12 RIBF148 DAQ starts
Degrader setting F11 1mm Al variable
AIDA file RIBF148/R2_85
BigRIPS file 2005
BRIKEN file 6
F11 rate ~200Hz
14.32 analysis file RIBF148/R2_89 - nnaida2 deadtime 0.6%, all other deatimes <0.5%, zero timewarps, three MBS
timewarps - see attachment 22
offline analysis RIBF148/R2_91
*** DSSSD # 1 count: 219696 old count: 166600 dt: 1.01 s LEC rate: 52719.37 Hz
*** DSSSD # 2 count: 346281 old count: 260940 dt: 1.01 s LEC rate: 84735.65 Hz
*** DSSSD # 3 count: 127888 old count: 95704 dt: 1.01 s LEC rate: 31955.71 Hz
*** DSSSD # 4 count: 89409 old count: 67186 dt: 1.01 s LEC rate: 22065.37 Hz
*** DSSSD # 5 count: 53702 old count: 40701 dt: 1.01 s LEC rate: 12908.78 Hz
*** DSSSD # 6 count: 83402 old count: 62481 dt: 1.01 s LEC rate: 20772.60 Hz
*** DSSSD # 1 count: 1 old count: 0 dt: 1.01 s HEC rate: 0.99 Hz
*** DSSSD # 2 count: 11 old count: 9 dt: 1.01 s HEC rate: 1.99 Hz
*** DSSSD # 3 count: 2 old count: 2 dt: 1.01 s HEC rate: 0.00 Hz
*** DSSSD # 4 count: 8 old count: 6 dt: 1.01 s HEC rate: 1.99 Hz
*** DSSSD # 5 count: 22 old count: 13 dt: 1.01 s HEC rate: 8.94 Hz
*** DSSSD # 6 count: 447 old count: 333 dt: 1.01 s HEC rate: 113.19 Hz
ADC & disc data synchronised - see attachment 24
online analysis - per DSSSD HEC x versus y - see attachment 23
14.43 all SortSas spectra zero'd
15.08 Detector biases & leakage currents OK - see attachments 25 & 26
FEE64 Temperatures OK - see attachment 27
good events statistics OK - see attachment 28
No warnings/errors reported by merger since DAQ GO - see attachment 29
*all* system wide checks OK *except* ADC calibration of nnaida1, 21 and nnaida1 clock status (status=6)
15.11 DAQ stop
AIDA file RIBF148/R2_101
15.13 RIBF148 DAQ starts
Degrader setting F11 1mm Al variable
AIDA file RIBF148/R2_102
BigRIPS file 2006
BRIKEN file 7
15.37 DAQ stop
AIDA file RIBF148/R2_109
online analysis - per DSSSD HEC x versus y
per DSSSD HEC E_p versus E_n - see attachments 30 & 31
heavy-ions stopped:transmitted ~50:50
15.42 RIBF148 DAQ starts
Degrader setting F11 *all out*
AIDA file RIBF148/R2_110
BigRIPS file 2007
BRIKEN file 8
*all* SortSas spectra and online histograms zero'd |
|