Message ID: 206     Entry time: Tue Mar 28 17:02:19 2017
Author: DK 
Subject: Applying Biases 
Today, Gabor and I discussed with Nathan from ORNL about the biasing system used for Ge, 3He, Plastic, and others.  Phong is also a bit familiar with the system (edit also 
Shintaro 
Go).  While there 
is supposed to be a manual, Gabor and I did not find it.
In case of trouble: contact Nathan Brewer Gmail: Brewer.nathant@gmail.com Skype: nathan.t.brewer

Log in to high voltage PC:

$ ssh -Y pixie16@10.32.6.161
passwd: ************

For HV readout, run firefox in the background

$ firefox &

You can probably check the history or restore pages, but it should be pointed
at 192.168.13.239

It updates automatically every several seconds.  Unless the HV monitor is
running, it may show nothing...

For temperatures:

$ cd ~/DAQ_1/kelvin
$ ./kelvin-read

(there are options to kill all temperatures)

For applying existing HVs (BE CAREFUL!)

$ cd ~/DAQ_1/hv-mpod
$ ./hvmon

If you want to change the voltages (up or down) kill this with Ctrl+C

To alter bias values or change which ones are on, you can edit the file:

$ ~/DAQ_1/include/hvmon.conf

Once the file is saved, restart hvmon.

We are running the above in a GNU screen session, with firefox on one computer.  It has a note taped to it.  Please don't use this computer for other purposes unless necessary!  
Let me note that the PC we log in through has essentially no .screenrc file so you can barely understand you are actually using screen.  If you are not very familiar with 
screen, better not to touch it.  I will put a better .screenrc later (but I also don't want to change the setup now).

28 Mar 2017 15:47:31

Ge voltage application

LN2 filling was done yesterday before lunch

D is the beam left side Ge
	MPOD	name
	U300	D4K
	U301	D4R
	U302	D4G
	U303	D4B

83.7 K, with 300 V

G is the beam right side Ge
	MPOD 	name
	U304	G7K
	U305	G7R
	U306	G7G
	U307	G7B

79.6 K with 250 V (except G7R at 300 V)

All analog signals are seen in the oscilloscope with reasonable behavior

28 Mar 2017 15:56:03 

Ramp up all Ge clovers.

D at 3000 V for all

G at 2500 V for all (except G7R is 3000)

28 Mar 2017 16:26:39 

Biases are all applied (maybe several minutes earlier)

D4 temp 83.7 K
G7 temp 79.6 K

28 Mar 2017 17:51:09 

Now we ramp up 3He and plastics.  We keep the Ge on during this time.

D4 83.7 K
G7 79.6 K

Everything looks good!