AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
BRIKEN
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Mon Mar 31 13:21:58 2025
Author
*
:
Subject
*
:
<p>You can start applying HVs on the detectors using macro on the control-computer.</p> <p>If you have already signed in the computer that controls mpod,</p> <p>1. Type http://192.168.13.239/ to monitor the status of HV.</p> <p>2. Go to the directory : /home/pixie16/DAQ_1/include and open the config file : hvmon.conf</p> <p>Type IP address channel slot name voltage Current RampUp RampDn Switch On/Off/RESET<br /> V A V/s V/s 1 / 0 / 10<br /> ------ --------------- --------- ----- ---- ------- ------- ------ ------ -------------<br /> 0 192.168.13.239 0 0 PA1 1450 0.0001 50 10 0<br /> 0 192.168.13.239 1 0 PA2 1450 0.0001 50 10 0<br /> 0 192.168.13.239 2 0 PA3 1550 0.0001 50 10 0<br /> 0 192.168.13.239 3 0 PA4 1550 0.0001 50 10 0<br /> 0 192.168.13.239 4 0 PA5 1550 0.0001 50 10 0<br /> 0 192.168.13.239 5 0 OFF 0 0.0001 50 10 10<br /> 0 192.168.13.239 6 0 OFF 0 0.0001 50 10 10<br /> 0 192.168.13.239 7 0 OFF 0 0.0001 50 10 10<br /> 0 192.168.13.239 0 1 PA6 1200 0.0001 50 10 0<br /> 0 192.168.13.239 1 1 PA7 1750 0.0001 50 10 0<br /> 0 192.168.13.239 2 1 PA8 1750 0.0001 50 10 0<br /> 0 192.168.13.239 3 1 PA9 1750 0.0001 50 10 0<br /> 0 192.168.13.239 4 1 PA10 1750 0.0001 50 10 0<br /> 0 192.168.13.239 5 1 OFF 0 0.0001 50 10 10<br /> 0 192.168.13.239 6 1 OFF 0 0.0001 50 10 10<br /> 0 192.168.13.239 7 1 OFF 0 0.0001 50 10 10<br /> 0 192.168.13.239 0 3 D40 3000 0.0001 2 5 0<br /> 0 192.168.13.239 1 3 D41 3000 0.0001 2 5 0<br /> 0 192.168.13.239 2 3 D42 3000 0.0001 2 5 0<br /> 0 192.168.13.239 3 3 D43 3000 0.0001 2 5 0<br /> 0 192.168.13.239 4 3 G70 2500 0.0001 2 5 0<br /> 0 192.168.13.239 5 3 G71 3000 0.0001 2 5 0<br /> 0 192.168.13.239 6 3 G72 2500 0.0001 2 5 0<br /> 0 192.168.13.239 7 3 G73 2500 0.0001 2 5 0<br /> <br /> When you want to start HVs, you may have to change the last bit to be 1.</p> <p>Then go to the following path /home/pixie16//DAQ_1/hv-mpod and execute the command ./hvmon (The process should start),</p> <p>When you want to down HVs, you may have to change the last bit to be 1.</p> <p>Sometime you may get error messages colored red on the status monitor when you down the HVs, then you have to change the config file (hvmon.conf) and set the last bit to be 10 to clear the error messages.</p> <p> </p> <p>--------------------------------------</p> <p>The IP adress of the computer is currently 192.168.13.250. The user name : pixie16, password: ask Nathan or Shintaro</p> <p>For now, slot names PA should be He3 and DXX and GXX should be clovers.</p> <p>You can also change the HV values by changing hvmon.conf</p> <p> </p> <p> </p> <p> </p> <p> </p>
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown