Water cooling has been connected to the FEE's. Flow meter installed to outlet manifold by way of two right angled pieces. No leaks observed rom any points in the coolant loop, loop will be bled using taps tomorrow. Water turned OFF overnight.
FEE's powered up with the MAC addresses of each read. 1 is the very bottom FEE and 8 the very top. FEE's have also labelled with the MAC addresses.
1. 0xd8 0x80 0x39 0x42 0x0d 0x0c
2. d8:80:39:41:d8:2b
3. d8:80:39:41:d0:05
4. 0xd8 0x80 0x39 0x41 0xd7 0xc2 (Now AIDA 5 see elog 185)
5. 0xd8 0x80 0x39 0x41 0xb4 0x0b (Now AIDA 4 see elog 185)
6. d8:80:39:41:d8:20
7. 0xd8 0x80 0x39 0x41 0xb4 0x16
8 .0xd8 0x80 0x39 0x41 0xd7 0xcd
MACB firmware has been updated by Nic
One ion pump showed the warning 'arcing' (see attached photo) and was subsequently turned OFF. Most likely cause is the cable was moved during installlation of the flow meter as the pump showed no error this morning. The pump was turned back ON, no error observed -> cable not damaged but sensitive to movement. |