AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
CARME
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Thu Jan 27 21:33:40 2022
Author
*
:
Subject
*
:
<p>Power, Ethernet and HDMI cables connected to FEEs. To prevent cables coming out of connectors, power and HDMI cables are zip tied to FEE cooling pipe (see attached image).</p> <p>Correct FEE MAC addresses have been updated in /etc/dhcp/dhcpd.conf</p> <p>Remote access to carme sever has been setup. Remote access instructions in elogs 176-179. </p> <p>New ASIC settings which reflect polarity of FEES produced 2022Jan27-16-43-00 </p> <p>New Options file updated to point to new ASIC settings. </p> <p>/MIDAS/config/TclHttpd/carme-gsi@8015/startup.tcl updated for 8 FEEs </p> <pre> /MIDAS/Linux/startup/NewMerger Updated line from "./master64 -i 16 -l 16 -p 11001 &" to "./master64 -i 8 -l 16 -p 11001 &"</pre> <p>Quick motors test performed. Motors accesible remotely (elog 179). Motors moving output (BNC 1 on motors box) connected to motors module (BNC 1). When not moving +12V is observed at BNC 2 on motors module. When moving 0V is observed on BNC 2. </p>
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Resubmit as new entry
Attachment 1:
20220127_101513.jpg
Original size: 4000x3000
Attachment 2:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown