<p>Power, Ethernet and HDMI cables connected to FEEs. To prevent cables coming out of connectors, power and HDMI cables are zip tied to FEE cooling pipe (see attached image).</p>
<p>Correct FEE MAC addresses have been updated in /etc/dhcp/dhcpd.conf</p>
<p>Remote access to carme sever has been setup. Remote access instructions in elogs 176-179. </p>
<p>New ASIC settings which reflect polarity of FEES produced 2022Jan27-16-43-00 </p>
<p>New Options file updated to point to new ASIC settings. </p>
<p>/MIDAS/config/TclHttpd/carme-gsi@8015/startup.tcl updated for 8 FEEs </p>
<pre>
/MIDAS/Linux/startup/NewMerger Updated line from "./master64 -i 16 -l 16 -p 11001 &" to "./master64 -i 8 -l 16 -p 11001 &"</pre>
<p>Quick motors test performed. Motors accesible remotely (elog 179). Motors moving output (BNC 1 on motors box) connected to motors module (BNC 1). When not moving +12V is observed at BNC 2 on motors module. When moving 0V is observed on BNC 2. </p> |