AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  CARME  ELOG logo
Message ID: 266     Entry time: Thu Feb 24 07:25:53 2022
Author: OH (Remote) 
Subject: Recover of system after crash 
08:00 Woke up to message from Carlo explaining the server had crashed.
      Anydesked into the machine.
      Merger was showing just data transfer it was not showing Transfer => Merger

      Went through the steps detailed in https://elog.ph.ed.ac.uk/DESPEC/36 to recover it.
      After following these steps was again able to forward data from the merger.
      Tested and it now sends on data again.

      Setup the screen session for the caen bias and restarted the logger program.
      Restarted the gnuplot script to plot leakage current
      Started the online monitoring software and browser.

      Have posted in the chat that the DAQ is now running again.
ELOG V3.1.4-unknown