Entry time:
Thu Oct 29 08:02:29 2020
Author
*
:
Subject
*
:
Attached is the temperature plot for bakeout period including tags for NEG activation etc. 28 October -> 27 November --->See shared Excel document for CARME pressure values<--- https://uoe-my.sharepoint.com/:x:/g/personal/cbruno2_ed_ac_uk/EbaoBvhq8zFFtmuakXKjQWQBTqjjzilT6lk9BmchoxlMNQ?e=XU8DzE 30 October 07:30 Baking code has been shut down, we have no log of the temperatures. Restarted (T=0) 19:40 Pressure back in the E-12 mbar range. 31 October 08:47 Back in the low E-11 mbar range. See temperature plot attached. 15:57 Back in the E-12 mbar range. 1 November 12:30 Pressures updated. Temperature plot updated. 2 November 08:52 Pressure reached E-10 mbar overnight, now back in the E-12 range. Temperature increasing. See attached. 3 November 08:37 Pressure stable in the E-12 mbar range. 15:36 Pressure mostly stable in the E-12 mbar range 17:30 KM reports re-arranging the mains power connection to borrow an extension reel. No obvious effects on pressure. 18:24 Pressure stable in the E-12 mbar range. Updated temperature plot. 4 November 08:39 Pressure stable in the E-12 mbar range. Temperature plot updated. 19:31 Pressure mostly stable around 5E-12 mbar 5 November 10:26 Pressure stable in the E-12 mbar range. 6 November 12:26 Pressure stable in the E-12 mbar range. 7 November 11:50 Pressure stable in the E-12 mbar range. Temperature plot updated. 8 November 20:39 Pressure increasing again. Now in 1E-11 mbar range 9 November 08:50 Pressure returned to E-12 mbar range. Temperature plot updated 16:51 Pressure fluctuating around 7E-12 mbar range. 10 November 09:04 Pressure oscillating in the 7E-12 mbar range 11 November 08:27 Pressure mostly stable in the 5E-12 mbar range 12 November 08:21 Pressure mostly stable in the 5E-12 mbar range 13 November 08:29 Pressure increased suddenly to 7E-9 mbar yesterday at 14:00, from 6.5E-12 mbar. Was the valve closed? (Confirmed by KM) Pressure appears to be slowly recovering. Currently in the low E-10 mbar range. Temperature plot updated. 15:40 Pressure does not appear to drop. Currently stable around 2E-10 mbar 18:10 KM reports Ion pumps have gone off (tripped by high pressure?) IE514 gauge still reading 1E-10, but SAES D2000-10 ion pressure gauge reading 1E-12. Someone will check tomorrow in person. 14 November 08:13 Pressure stable in the 2E-10 mbar range. Does not appear to decrease. 15 November 08:24 Pressure stable in the 2E-10 mbar range 16 November 08:23 Pressure increased to 1E-9 mbar (potentially due to heating being turned on at week start). 17 November 08:18 Pressure back in the E-12 mbar range since yesterday afternoon. Change was sudden and CM52 control module appears to have been moved in-between. Unclear what was done locally. 18 November 08:40 Pressure mostly stable in the 5E-12 mbar range. 19 November 07:55 Pressure remains stable in the E-12 mbar range. Temperature plot updated 20 November 08:00 Pressure remains stable in the E-12 mbar range. 21 November 14:16 Pressure remains stable in the 5E-12 mbar range. 22 November 08:08 Pressure remains stable 23 November 08:24 Pressure remains stable 24 November 08:05 Pressure remains stable See ELOG entry by JM 25 November See ELOG entry by TD. Valve partly closed. 26 November 08:58 Pressure in the E-10 mbar range, very slowly decreasing 27 November 21:07 Pressure stable in the 2E-10 mbar range. Does not appear to be decreasing 28 November 17:49 Pressure stable in the 2E-10 mbar range.
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Resubmit as new entry
Attachment 1:
20201029_080001.jpg
Original size: 640x480
Attachment 2:
Bakeout_pump_down.png
Original size: 640x480
Attachment 3:
20201119_temps.png
Original size: 1920x1037
Attachment 4:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown