Message ID: 337     Entry time: Tue Mar 1 02:15:29 2022
Author: JM, EM 
Subject: Current status 

03:15

The nozzle motor control at the target crashed, but operation has been restored.

Temperature setpoint = 116 K

Detector position IN potentionmeter = 34.89mm

Rutherford rate fluctuates, around 100 counts peak height

Merger OK

Data rate = 1356 kb/sec

Leakage current = 3.234 uA

Temperatures OK

System checks OK - wr fails


         Base         Current     Difference
aida01 fault      0xab60 :      0xab8c :      44  
aida02 fault      0x88d3 :      0x88fe :      43  
aida03 fault      0x23aa :      0x23d6 :      44  
aida04 fault      0x15d7 :      0x1603 :      44  
aida05 fault      0x2f03 :      0x2f0f :      12  
White Rabbit error counter test result: Passed 0, Failed 5

Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR

Avg ring pressure = 4.4 E-10 mbar

Attachment 1: 2022-03-01_03-21-28_Exrate.png  157 kB  | Hide | Hide all
2022-03-01_03-21-28_Exrate.png
Attachment 2: 2022-03-01_03-22-30_ExTotal.png  162 kB  | Hide | Hide all
2022-03-01_03-22-30_ExTotal.png
Attachment 3: 2022-03-01_03-23-06_EyTotal.png  172 kB  | Hide | Hide all
2022-03-01_03-23-06_EyTotal.png
Attachment 4: 2022-03-01_03-25-54_GoodEvents.png  104 kB  | Hide | Hide all
2022-03-01_03-25-54_GoodEvents.png
Attachment 5: 2022-03-01_03-26-48_Correlations.png  103 kB  | Hide | Hide all
2022-03-01_03-26-48_Correlations.png
Attachment 6: 2022-03-01_03-27-23_ADCdataitems.png  103 kB  | Hide | Hide all
2022-03-01_03-27-23_ADCdataitems.png
ELOG V3.1.4-unknown