AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
CARME
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Apr 5 22:16:14 2025
Author
*
:
Subject
*
:
<p>18:21</p> <p>Temperature setpoint = 113k</p> <p>Target density OK S1 varies between 2E-8 and 2.5E-8 mbar, E4 between 1E-9 and 5E-9 mbar. (slightly lower than previous check)</p> <p>Detectors moving well between 23.1mm and 67.43 mm, Move in and move out counters the same. Correlation scalar is on aida1</p> <p>Rutherford peak varies between 10^3 and 10^2 depending on detector position. No halo peak in rate. Noise peak varies from ~100 peak height when fully in to ~400 peak height when fully out.</p> <p>Beam intensity ~ 1E8</p> <p>Merger OK</p> <p>Data rate ~ 1800 kb/sec</p> <p>Leakage current ~3.21 uA</p> <p>Temperature OK<br /> System checks OK - wr fails</p> <p> Base Current Difference<br /> aida01 fault 0xab60 : 0xaba3 : 67 <br /> aida02 fault 0x88d3 : 0x8914 : 65 <br /> aida03 fault 0x23aa : 0x23ed : 67 <br /> aida04 fault 0x15d7 : 0x161a : 67 <br /> aida05 fault 0x2f03 : 0x2f20 : 29 <br /> White Rabbit error counter test result: Passed 0, Failed 5</p> <p>Understand the status reports as follows:-<br /> Status bit 3 : White Rabbit decoder detected an error in the received data<br /> Status bit 2 : Firmware registered WR error, no reload of Timestamp<br /> Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR</p> <p>Avg ring pressure = 4.4 E-10 mbar</p> <p>19:20</p> <p>Temperature setpoint = 113k</p> <p>Target density OK S1 varies between 2E-8 and 3E-8 mbar, E4 between 1E-9 and 1E-8 mbar. (slightly higher than previous check)</p> <p>Detectors moving well between 23.1mm and 67.43 mm, Move in and move out counters the same. Correlation scalar is on aida1</p> <p>Rutherford peak varies between 10^3 and 10^2 depending on detector position. No halo peak in rate.</p> <p>Beam intensity ~ 1E8</p> <p>Merger OK</p> <p>Data rate ~ 1800 kb/sec</p> <p>Leakage current ~3.20 uA</p> <p>Temperature OK<br /> System checks OK - wr fails</p> <p> Base Current Difference<br /> aida01 fault 0xab60 : 0xaba4 : 68 <br /> aida02 fault 0x88d3 : 0x8915 : 66 <br /> aida03 fault 0x23aa : 0x23ee : 68 <br /> aida04 fault 0x15d7 : 0x161b : 68 <br /> aida05 fault 0x2f03 : 0x2f20 : 29 <br /> White Rabbit error counter test result: Passed 0, Failed 5</p> <p>Understand the status reports as follows:-<br /> Status bit 3 : White Rabbit decoder detected an error in the received data<br /> Status bit 2 : Firmware registered WR error, no reload of Timestamp<br /> Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR</p> <p>Avg ring pressure = 4.3 E-10 mbar</p> <p>Statistics similar to previous check.</p>
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown